| 1 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out getting out complete all as specified and as directed. |
| 2 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. |
| 3 | Removing excavated soil to a distance not exceeding 50 metre away and depositing where as directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed. |
| 4 | Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete including necessary form work complete all as specified and as directed. |
| 5 | Material and Labour plain cement concrete 1:2:4 type B2 using 40mm graded granite stone aggrgate as on foundations filling and mass concrete, and finishing cement concrete surface even and smooth Without using extra cement, complete all as specified and as directed. |
| 6 | M&L for Pre-cast cement concrete block masonry with solid blocks using type C1(1:3:6) (20mm graded aggregate) ,size exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 7 | Material and labour for Precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs of man holes including necessary form work, placed in position, set in CM 1:4 complete all specified and as directed. |
| 8 | Material and Labour for TMT bar 10mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping ,for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 9 | M&L mild steel TMT bars 5mm dia and over up to 10mm for stirrups cut to length , bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia bars complete in all respect as specified and directed. |
| 10 | Excavation over areas exc 1.5 m depth and n. exc 3.0 m deep and getting out in soft/loose soil complete all as specified and as directed. |
| 11 | Material and labour for Loose filling with broken stone aggregates of gauge 40 to 80 mm in soakage pits, soakage wells, etc complete all as specified and as directed. |
| 12 | Material and Labour for Sand filling under floors or in foundations, levelled and rammed including watering and consolidation all as specified and as directed. |
| 13 | Material and Labour for PCC 1:3:6, type C-2 as in concrete bed to drain pipes including packing under and completely surrounding pipes after they are laid and tested for 100mm dia pipe and testedcomplete all as specified and as directed. |
| 14 | Material and Labour for PCC 1:3:6, type C-2 as in concrete bed to drain pipes including packing under and completely surrounding pipes after they are laid and tested for 150mm dia pipe and testedcomplete all as specified and as directed. |
| 15 | S&F (spun pipes) cast iron soil, waste and vent pipes 100 mm dia in any length with or without ears, with cement joints laid in trenches or on floor complete all as specified and as directed. |
| 16 | S&F (spun pipes) cast iron soil, waste and vent pipes 150 mm dia in any length with or without ears, with cement joints laid in trenches or on floor complete all as specified and as directed. |
| 17 | S&F in repair PVC (SWR) pipes 110 mm dia. single socketed, in any length with rubber ring joints, fixed to wall and roof as in rain water gutters including cutting of PVC pipes in half complete all as specified and as directed. |
| 18 | S&F PVC (SWR) bend 110 mm dia with access door complete all as specified and as directed. |
| 19 | S&F PVC (SWR) junction single 110 mm bore, (single T) equal or unequal with access door complete all as specified and as directed. |
| 20 | S&F PVC (SWR) 110 mm bore vent cowl complete all as specified and as directed. |
| 21 | S&F PVC (SWR) pipes 75 mm dia. single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed. |
| 22 | S&F PVC (SWR) bend 75 mm dia with access door complete all as specified and as directed. |
| 23 | S&F PVC (SWR) 75 mm bore vent cowl complete all as specified and as directed. |
| 24 | Material and labour for 15 mm thick rendering on brick/concrete surfaces in two layers in CM 1:4, finishing coat of 5mm thick, finished even and smooth without using extra cement complete all as specified and as directed. |
| 25 | Material and labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. Please Enable Macros to View BoQ information |