| 1 | Excavation in trenches not exc 1.5 mtr width and not exce 1.5 mtr in depth in soft/loose soil and getting complete all as specified and as directed. |
| 2 | M&L for sand cushioning /sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. |
| 3 | M&L bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and as directed. |
| 4 | Laying in Trenches Bricks (Serviceable Bricks obtained from Item No. 7.00 here-in-after), for Cable Protection, complete all as specified and as directed. |
| 5 | Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed. |
| 6 | Removal of excavated material to a disance n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 7 | Taking down unserviceable LT XLPE cable 400/1000 Sqmm for replacement etc (from cable duct/underground trench), stacking properly (cable, pipe and bricks) complete all as specified and directed by the Engr-in-Charge. |
| 8 | Supply and fix in repair of bus bar trunking system for the complete bldg power supply duly insulated three phase of rating 630Amps, 25 KA 415 Volts aluminium conductor galvanised GI enclosure 0.8mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including end feed unit with MCCB 160 A 25 KA 4P with rotary handle, termination links of bldg including following: |
| 9 | A.Vertical rising trunking system of rating 630 Amp |
| 10 | a) Straight length with plugin oultet - 15 mtr (approx) |
| 11 | b) Flange end - 01 Nos |
| 12 | c) End cap - 01 Nos |
| 13 | d) Brackets - 25 Nos |
| 14 | e) Springs support - 10 Nos' |
| 15 | f) Fire barrier -Complete set as required at site |
| 16 | g) Adpator box- Complete set as required at site |
| 17 | h) Copper braided flexibles - Complete set as required at site |
| 18 | j) External GI erath strip 32x6 - 30 Rm |
| 19 | B.Lightning trunking 63 Amp ,horizontal for each floor |
| 20 | i) 63A 4P lightning trunking @ 3.0 Mtr length - 5 Nos |
| 21 | ii) MS 63 Flexible Elbow -Complete set as required at site |
| 22 | iii) MS 63A AL RH Horizontal Elbow -Complete set as required at site |
| 23 | iv) MS 100 centre feed unit IP 55-20 Nos |
| 24 | v)MS 63A AL RH Horizontal Elbow -Complete set as required at site |
| 25 | vi)End cover IP55 - 20 Nos |
| 26 | vii)MS Sleeve IP55 - 10 Nos |
| 27 | viii)MS Plug POINT GASKET IP55 - 10 Nos |
| 28 | ix)SUSPENSION BRACKETS - 60 Nos |
| 29 | C.125 A Tap-off box with 63 Amp ,16KA,4 Pole MCCB-10 Nos |
| 30 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts, of cross sectional area 400 Sqmm, 3.5 core complete all as specified and directed. |
| 31 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts, of cross sectional area 300 Sqmm, 3.5 core complete all as specified and directed. |
| 32 | S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable upto 400 Sqmm, single core including testing on completion complete all as specified and directed by the Engr-in-Charge. |
| 33 | Taking down unserviceable Galvanised steel tubing Pipe 100/150 mm bore replacement etc (from underground trench/pole), complete all as directed by the Engr-in-Charge. |
| 34 | M&L for Galvanised Steel Tubing Pipe 150 mm bore (dia), light grade with Bends, laid in Trenches or under Roads/ Flooring/ Culverts etc., complete all as specified and as directed. |
| 35 | Excavation/Cutting Road/ Hardstanding in Trenches not exc. 1.00 Meter wide and not exc. 1.00 Meter in depth and getting out, complete all as specified and as directed. |
| 36 | Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate complete all as specified and directed. |
| 37 | Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. Please Enable Macros to View BoQ information |