| 1 | M&L for 100 bore Galvanised steel tubing light grade for protection of under ground cable on poles/walls under road crossing etc conforming to IS: 1239 complete all as specified and directed. |
| 2 | M&L for 80 bore Galvanised steel tubing light grade for protection of under ground cable on poles/walls under road crossing etc conforming to IS: 1239 complete all as specified and directed. |
| 3 | M & L for earthing complete with galvanised for steel earth plate electrode 60×60cm.×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 including necessary excavation and earth work GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with PCC cover in cement concrete 1:2:4 Type B1(20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated including testing complete all as specified and directed. |
| 4 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip 25 x4 mm (up to 7.5 m in length from earth plate ) by means of bolts and nuts check nuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia medium grade for protection of earth electrode 20 mm dia for watering all as specified and directed and tested on completion complete all as specified and directed. |
| 5 | Excavation in trenches not exc.1.5 mtr wide and not exc.1.5 m in depth for foundation of poles, stay assembly and laying of LT/HT cable as in Soft/loose of soil and getting out, complete all as specified and directed. |
| 6 | All as per ser item No 5 above but depth exceeding 1.5 m and not exceeding 3 m. |
| 7 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil, complete all as specified and directed. |
| 8 | Removal of excavated material to a distance not exc.50 m and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed. |
| 9 | M&L for sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified and directed. |
| 10 | M & L Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed. |
| 11 | M&L for cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in bed of poles streets and stays all as specified directed. |
| 12 | M&L for cement concrete 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in coping of pole and stay assembly complete all as specified and directed. |
| 13 | M&L for Cement concrete in foundation of poles streets and stays 1:3:6 type C-2 using 40 mm graded crushed stone aggregate all as specified directed. |
| 14 | Supply & Laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles of following sizes :- |
| 15 | (a) 150 sq mm, 3.5 core |
| 16 | (b) 120 sq mm, 3.5 core |
| 17 | (c) 95 sq mm, 3.5 core |
| 18 | (d) 70 sq mm, 3.5 core |
| 19 | (e) 50 sq mm, 3.5 core |
| 20 | (f) 35 sq mm, 3.5 core |
| 21 | (g) 25 sq mm, 3.5 core |
| 22 | (h) 16 sq mm, 4 core |
| 23 | S & F steel tubular swaged poles erected truly vertical or planted as strut complete with 300 x300x 6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap, bolts, nuts & screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II. type 410 SP-31 (9.0 metres long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally & portion embedded in concrete, making five black & yellow bands at lower portion of pole each 300mm wide alternately, and making pole No. with black paint at suitable height complete all as specified and directed. |
| 24 | M&L for Galvanised steel wire of size 4mm dia stretching, fixing and binding to pole to pole for earth continuity with binding wire or Aluminium tapes which shall not be included in weight of conductor complete all as specified and directed. |
| 25 | M&L for ACSR conductor of size 6/2.59 (aluminium) 1/.59 (Steel including stretching, fixing and binding to insulator on OH LT/HT line service feeders all as specified including aluminium binding wire or aluminium tapes complete all as specified and directed. |
| 26 | M&L for Shackle type, porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts grade, 90 mm dia 75 mm height including galvanized mild steel straps of 31 x 3 mm size, 12 mm dia insulator bolts, washers and nuts complete all as specified. |
| 27 | M & L for pin type, porcelain, vitreous, white or brown insulator including one galvanised mild steel spindle, one galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia for 1100 (LT) volts grade. complete all as specified and directed. |
| 28 | M&L for mild steel work as in cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface complete all as specified and directed. |
| 29 | M & L for stay assembly complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately), Diameter of stay rod in 20 mm, complete all as specified and as directed. |
| 30 | M & L for Loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 90 x 140mm clearance of hole 25.5 mm, complete all as specified and as directed. |
| 31 | S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminium stranded conductor served with PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension ire one twin core flat cable of circular of size 10 sqmm .complete all as specified and directed. |
| 32 | S&F 1100 volt grade heavy duty cable PVC insulated multistranded aluminium stranded conductor served with PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm dia GI suspension ire one twin core flat cable of circular of size 16 sqmm complete all as specified and directed. |
| 33 | M&L for danger Notice plate of 1.6mm thick mild steel, vitreous enamelled white, with letter, figures and conventional skull bones in signal red colour and fixed with mild steel clamps, nuts, bots and washers clamps made out of 25x3mm flat iron for HT poles/transformers/pillar box etc with voltage and danger indicated in Hindi and English complete all as specified and directed of size 25x20cm complete all as specified and directed. |
| 34 | Supply, installation, testing and commissioning ,factory made and tested (prototype having been CPRI type test certified), LT Panel outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50Hz AC supply, having bus bar chamber with insulated copper bus bar of 500 Amps rating installed on porcelain insulator. The Panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 40x40x6mm thick angle iron frame work, externally powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry with double door shutter and locking arrangement (including provision of 65 mm Godrej (Freedom) lock with 2 key, internal wiring 2.5 Sqmm with PVC insulated, sold copper conductor ,FRLSH cables, IS-694 marked of adequate size including the provision of space to accommodation the under mentioned items. The scope of work includes the following:- |
| 35 | (a) Incoming (i) MCCB 4 pole 415 volts AC grade,400 Amps rating and 35 KA rupturing complete with microprocessor based OL protection - 01 No (ii) Voltmeter 0-500 volts,square,144 mm, digital type , flush pattern with 3 way rotary selector switch - 01 No (iii) Ammeter size 144 mm, square dial, digital type, flush pattern having dual range 500 Amps with three way rotary selector switch with suitable size of LTs - 01 No (iv) LED indicating lamps - 01 Set of Three (b) Outgoing :- (i) MCCB 3 pole, 415 volts AC grade, 250 Amps rating and 35 KA rupturing capacity complete with microprocessor based OL protection -02 No (ii) MCCB 3 pole ,415 volts AC grade , 63 Amps rating and 16 KA rupturing capacity complete with microprocessor based OL protection -01 Nos (iii) (c) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone,15cm thick foundation , brick work in CM 1:6 with sub class 'B' old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6 type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. |
| 36 | Supply, installation, testing & commissioning of CPRI approved LT Feeder Pillar Box, outdoor type, double door, front and back door openable type with dust vermin proof made out of CRCA sheet 3.15mm thickness, suitable for operation on 415V, 50 Hz, 3 Phase AC supply confirming to IP-65 including suitable size of 4 pole aluminium bus bar of capacity 300 Amps complete with frame made out of angle iron of size 50x50x6 mm for mounting of panel 45cm above ground level, ground level, grouting by providing PCC 1:3:6 type C1 , using 20mm grade crushed stone aggregate powder coated having thickness not less than 100 microns including seven tank process suitable for and including the following :- (a) MCCB 160 Amps FP 25KA-01 No (b) Amp meter -0-200 Amp with CTS -01 No (c) Voltmeter (0-500V) -01 No (d) Selector switches -01 each |
| 37 | Supply and fix in LT Straight through joint heat shrinkable 1100 volts, 25 sqmm to 50 sqmm including dismantling the existing unserviceable cable complete all as specified and directed. |
| 38 | Supply and fix LT Straight through joint heat shrinkable 1100 Volts, 70 sqmm to 150 sqmm including dismantling the existing unserviceable complete all as specified and directed. |
| 39 | Supply and installation of air cooled spilt unit air conditioner electric driven single phase of cooling and heating type split ACs capacity of 2 TR, BEE 5 star rated complete all as specified and directed. |
| 40 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed. |
| 41 | Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 75 KVA complete all as specified and directed. Please Enable Macros to View BoQ information |