| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cables, foundation for pole, etc and getting out in hard/dense soil complete all as specified and as directed. |
| 2 | Excavation in trenches exceeding 1.5 m wide and not exceeding 3.0 m in depth for laying cables, foundation for pole, etc and getting out in hard/dense soil complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming of soil in layers n. exc 25cm thick complete all as specified and as directed. |
| 4 | Removing excavated soil to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed. |
| 5 | M&L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 6 | M&L for PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 7 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping for the new/existing Steel Poles, cills, including necessary formwork (straight or curved) complete all as specified and as directed. |
| 8 | Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to requirred thickness complete all as specified and as directed. Note: Thickness of sand cushioning after punning down shall be measured for payment purpose. |
| 9 | Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed. |
| 10 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 95 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking down old unserviceable UG cable any type complete all as specified and as directed. |
| 11 | S&F 1100 volts grade heavy duty flat cable of size 10Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any description complete all as specified and as directed. |
| 12 | S&F 1100 volts grade heavy duty flat cable of size 16Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any description complete all as specified and as directed. |
| 13 | M&L for erection and fixing of steel tubular swaged pole type 410 SP - 44 (10.00 metres long) confirming to IS- 2713 Part I to III 1980 with and including cast iron base plate, finial taper plug, nuts, bolts and washers etc. fixed in PCC foundation duly painted painted with two coats of Aluminium paint over a coat of red oxide primer with 30 cm of black,yellow and white paint upto 1.2m including preparation of surface and including dismsntling of old pole of any size and description with foundation, PCC coping etc. complete all as specified and as directed. |
| 14 | M &L for preparing surfaces of existing HT steel tubular poles 11m long including scrapping, brushing down old paint with emery paper and applying two coat of aluminium paint including cross arms, street light brackets etc and making strip upto 1.5m above ground level by black/yellow paint in alternate layers with numbering of poles complete all as specified and directed. |
| 15 | Dismantling unserviceable/old ACSR conductors of any size from over head lines, poles by removing binding wire, service wire, cables and removal from site complete all as specified and as directed. |
| 16 | M&L for ACSR conductors (weasel type) for LT OH lines on poles including stringing, binding with aluminium wire 14 SWG or aluminium tape including jumpers complete connecting of disconnected cable, service cable and street light connection complete all as specified and as directed. |
| 17 | Refixing only old ACSR conductor obtained from dismantling of old ACSR conductors for LT OH lines on poles including stringing, binding with aluminium wire 14 SWG or aluminium tape including jumpers complete all as specified and as directed. |
| 18 | M&L for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including painting with two coat of aluminium paint over a coat of red oxide primer and including dismantling unserviceable cross arms, clamps etc complete all as specified and as directed. |
| 19 | M &L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size and including taking down of old ones complete all as specified and as directed. |
| 20 | S &F street light fitting of 60 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP65,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage including taking down old unserviceable light fittings complete all as specified and as directed.Note for item No.22&23: Contractor have to write date of changing in bold letter using permanent marker and submit minimum two years manufacturer warrantee certificate with purchase voucher on completion of work. |
| 21 | S &F street light fitting of 90 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded PC Cover having top opening seperate driver compartment ,should have luminaire efficacy ≥110 lumens/watt,CRI>70 ,PF > 0.95,CCT≥5500,IP65,impact resistance IK 07 ,inbuilt protection against lightning , over voltage , short circuit and surge/spike protection device upto 5 kVcomplete also tested for 440 Volt for 8 hour Phase to phase without any damage including taking down old unserviceable light fittings complete all as specified and as directed. Please Enable Macros to View BoQ information |