| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: MILITARY ENGINEERING SERVICES (GE (SOUTH) UDHAMPUR) NAME OF WORK : SPL REPAIR TO SECURITY WALL, COMPOUND WALL AT CERTAIN LOCATIONS OF BIKRAM ENCLAVE AND SAPPERS ENCLAVE AND OTHER SANCTION WORK UNDER GE (SOUTH) UDHAMPUR. Contract No: CA NO : GE/S(U)-23/2025-26 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out soft /loose soil complete all as specified and directed. |
| 3 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed. |
| 4 | Removing excavated material as in soil/rock n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point all as sepcified and directed. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 7 | Dismantling old unserviceable barbed wire/fencing wire mesh including removing from site all as specificed and directed. |
| 8 | Taking down cement plastering on brick/concrete walls incl taking out joints hacking for key scrubbing down with water etc complete all as specified and directed |
| 9 | Demolition of cement concrete un reinforced of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 10 | Demolition of reinforced cement concrete work of any description not specifically provided incl cutting down reinforcement complete all as specified and directed. |
| 11 | Demolition of brick or stone masonary including all necessary arches, pillars, quions etc built in cement mortar complete all as specified and directed. |
| 12 | M&L for cement concrete type D2 1:4:8 (40mm graded aggregate) in foundation complete all as specified and directed |
| 13 | Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter fair finished flat surfaces of concrete complete all as specified and directed. |
| 14 | Formwork to faces of walls,retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter fair finished flat surfaces of concrete complete all as specified and directed. |
| 15 | Formwork to pillars, coloumn and simiar work etc fair finished surfaces square, retangular and polygon. all as specified and directed. |
| 16 | Reinforced cement concrete M-25 (Design mix) (20 mm graded aggregate) using footing, foundation beams, plinth beam, roof beam, lintel band, retaining wall/toe wall and similar work etc complete all as specified and directed. |
| 17 | Reinforced cement concrete M-25 (Design mix) (20 mm graded aggregate) using columns, pillars and similar work etc. complete all as specified and directed |
| 18 | Reinforced cement concrete M-25 (Design mix) (20 mm graded aggregate) using beam, cantilevers, bressummers, lintels and similar work complete all as specified and directed. |
| 19 | Reinforced cement concrete M-25 (Design mix) (20 mm graded aggregate) using Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses etc complete all as specified and directed. |
| 20 | M & L mild steel TMT bars 10 mm dia and over cut to lenth, bent to shape required, including cranking,bending, spirally for hooping for columns, hooking ends and binding waith and including mild steel wire (annealed) not less than 0.9mm dia all as specified & directed. |
| 21 | Ditto as per item Sr.no 19 in before but 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders complete all as specified and directed |
| 22 | M&L for brick work with sub class 'B' brick straight or curved on plan exc 6m radious in CM 1:6 as in brick work/brick pillars etc complete all as specified and directed |
| 23 | M&L for stone masonry randum rubble un-coursed well bounded bedded and solidly hearted in CM 1:6 complete all as specified and directed. |
| 24 | Precast PCC 1:3:6, type C-1 (using 20mm graded stone aggregates) as in bond stones, set in CM 1:6 with match the joints all as specified and directed. |
| 25 | M & L for providing cement concrete 1:2:4 Type B1 using 20mm graded aggregate as in lintels up to 1.5m clear span, cills,seismic and other similar bands, plinth courses, copings, Bed blocks, and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 26 | M&L 15 mm thick rendering on fair faces of brick or concrete surfaces in CM 1:4 and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 27 | M&L for raised pointing to random or polygonal rubble masonary coursed or un coursed in CM (1:3) complete all as specified and as directed. |
| 28 | M&L for prepration of newly wall surfaces and applying two coats of cement base paint over a coat alkali resistance with curing properly complete all as specified and as directed. |
| 29 | M & L for hand packing (any thickness) of broken stone or boulder at back of walls over arches etc and raising (or lowering) to the required level all as specified and directed. |
| 30 | S & F 110 mm dia PVC (SWR) pipes single stack in any length as in weepholes of retaining wall all as specified and directed. |
| 31 | M & L for mild steel conforming to grade Fe-165 (Fe-290) angle post or struts in fencing fixed independently including cutting and bending to shape as directed drilling holes, notching for wire etc. complete all as specified and directed. |
| 32 | S&F for framed work such as grills, gratings & door etc.with ends of bars shouldered and/or riveted,or forged into spikes;walk ways; railings; and similar work conforming to Fe 290 Gde-E-165 complete all as specified and as directed. |
| 33 | Material and labour preparation of new steel surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide chrome primer all as specified and as directed. |
| 34 | Returning filling in incl spreading, levelling, watering and well ramming in layers n.exc 25cm thick as in soil/rock (excavated material) all as specified and directed. |
| 35 | S & F for galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of post including securing and tying at crossing with and provision of galvanised mild steel wire staple or steel pins etc all as specified and directed.(Each line wire to be mesured). |
| 36 | S & F for concertina coil 500mm dia and 150mm prolong fixing to any type of standard rails including screwing in position complete all as specified and directed. |
| 37 | Granite stone 18-20mm thick (table rubbed and polished) in window cills, cooking platforms and the like not less than 1 Sqm (in one piece), laid over 15mm thick layer of cement mortar 1:3 after roughening of existing concrete surface and applying a layer of neat cement slurry @ 3Kg/Sqm including pointing in white cement 1:2 using marble dust with admixture of pigments to match with shade of stone, including demolition of stone slabs and tiles of any description or thickness in floors etc. laid, bedded and pointed in any mortar complete all as specified and as directed. |
| 38 | S&F Stainless Steel box type writing letters (Block, Romen, Italic or Indian) of size 300-450mm hight, 50mm wide and 10mm depth(thick) or 3D LED illuminated glow sign board acrylic letters (size & design as approved by Engr in charge) complete all as directed. |
| 39 | M&L for Wall cladding coloured tiles 300x450x7mm or 300x600x7mm for external surfaces size and design as approved by Engr in Charge as in vertical surfaces of walls, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm cement rendering in cement mortar 1:4 complete all as specified and as directed. |
| 40 | M&L Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 15mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately) and applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and provide APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) all as specified and directed.Make of APP membrane : STP/IWL |
| 41 | M&L providing cement concrete 1:2:4 Type B1 using 20mm graded aggregate in roof kerbs of mud stops rounded or chamfered on edges complete all as specified and direted. |
| 42 | M&L for Glazed Coloured Ceramic tiles in vertical surface 450x300x7mm thick incl laid over 10 mm thick rendering in CM 1:4, set and joint in neat cement slurry and pointed in white or colour cement to match. |
| 43 | M&L for Non skid Ceramic coloured tiles (square/rectengular) 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc incl 10mm thick screed bed in cement mortar 1:4 for laying floor finishes under floo etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface. |
| 44 | All as per item above Sr.no. 42 but on vertical surfaces as in skirting incl laid over 10 mm thick rendering in CM 1:4. |
| 45 | M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in floor and finished even and fair. |
| 46 | Supply only integral water proofing compound complete all as specified and directed. |
| 47 | M&L two coats of cement base paint on walls including preparation on new/old surfaces complete all as specified and directed. |
| 48 | M&L for applying one coat of wall putty on walls to give uniform surface complete all as specified and directed. |
| 49 | M&L two coats of oil bound distemper on walls including preparation on new surfaces over a coat of primer complete all as specified and directed. |
| 50 | M&L for hardcore of broken stone of guage n.exc 63mm deposited spread and levelled in layer n.exc 15cm thick watered and well rammed to true surfaces as specified and directed. |
| 51 | M&L for 100mm thick PCC 1:4:8 Type D2 using 40 mm graded stone aggregates as in foundations filling and mass concrete. |
| 52 | M&L for sand cushioning under floors including watering and consolidation . complete all as specified and as directed. |
| 53 | M&L machine pressed precast concrete coloured interlocking paver block (glossy finish) any shape and size (sample approved by GE) confirming to IS 15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment. complete all as specified and directed. |
| 54 | Machine pressed (factory made) precast plain cement concrete 1:2:4 type B-1(20mm graded crushed stone aggregate), kerb stone & the like of size 300mm x 300mm x 100mm thick or of size as approved by GE, with plain fair faces including chamfers, weathering etc, embedding in position/laid in trenches on edges of roads, including excavation in any type of soil, setting in cement mortar (1:4) returning filling and removal of surplus soil/debris to a distance n.exc. 50m from the starting point. |
| 55 | M&L for Reinforced cocrete pipe 300 mm dia,class NP-3 laid to floor and wall jointed complete with collars |
| 56 | M&L for concrete bed to drain pipes 300 mm dia type 1:3:6 C-2 including paking under,and haunching against the sides of pipes after they are laid and tested. |
| 57 | Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket,fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as specified and directed. |
| 58 | Taking down main switches, distribution boards and cut outs etc. of any type and capacity along with the existing boards and removing the same from site and making good the disturbed surface/portion of walls complete all as specified and directed By Engr-in-Charge. |
| 59 | Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLSH copper conductor cables (multistranded) PVC insulated and unsheathed in and including PVC concealed conduit pipe as per site requirement (size not less than 20mm dia), medium grade with Modular sunken boxes & PVC/metal back plate for mounting modular type switches, sockets & regulators etc with cover plate modular type including supplying and laying PVC insulated and stranded unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire connected to earth dolly including cutting of chases in wall /ceiling etc and making good the disturbed surfaces match to existing with cement mortar and putty white /colour wash complete all as specified and directed . Make: Havells/ Finolex/ Polycab. |
| 60 | All as per item no 58 above but cable 2.5 sqmm FRLSH for one 3/5 pin 6 Amp socket outlet point on an independent board. |
| 61 | All as per item no 58 above but cable 2.5 sqmm FRLSH for one 3/5 pin 6 Amp socket outlet point on the same board with other switch. |
| 62 | All as per item no 58 above but for Two way point control by Two two way 6 Amp switch. |
| 63 | All as per item no 58 above but for one 3/6 pin 16 amps socket outlet point on an independent board with cables of size 2.50 sqmm. |
| 64 | All as per item no 58 above but an independent board with cables of size 4.0 sqmm. |
| 65 | S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with outer cover complete all as specified and directed by Engr-In-Charge charge.Make:Legrand/Havell crabtree/L &T |
| 66 | S&F Switch modular, flush type, single pole, Two way 5/6 Amp 230 Volts complete all as specified and directed. Make:Legrand/Havell crabtree/L &T |
| 67 | S&F modular bell push, flush type, single pole, one way 5/6 Amp 230 volts complete all as specified and directed. Make:Legrand/Havell crabtree/L &T |
| 68 | S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and directed by Engr-In-Charge .Make:Legrand/Havell crabtree/L &T |
| 69 | S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with outer cover complete all as specified and directed by Engr-In-charge.Make:Legrand/Havell crabtree/L &T |
| 70 | S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with outer/inner cover complete all as specified and directed by Engr-In-charge. Make:Legrand/Havell crabtree/L &T |
| 71 | S&F Lamp holder PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 72 | S&F sub main wiring with two single core FRLSH PVC insulated unsheathed multistranded copper conductor of size 6 Sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area FRLSH PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including 25 mm dia 'medium grade' PVC concealed conduits and fittings, complete all as specified and directed.NOTE: One unit length shall measured as two run of main wire and one run of conduit & earth wire Make: Havells / Finolex / Polycab. |
| 73 | S&F LED retrofit lamp of capacity 12 watt, B-22 holder base with polycabonate body and aluminium heat sink warm white/day light complete all as specified and directed. Make- Philips or techno commercial equivalent in Bajaj/ Syska |
| 74 | S&F in replacement ceiling rose, 3 terminal, PVC/ Polycarbonate, insulated body,surface bakelite sheet 63.50mm dia complete all as specified and directed. |
| 75 | S&F in replacement electronic step type fan regulator 100 watt 230 volts 50Hz two module C/S deluxe type complete all as specified and directed. Make: Havells Crabtree/ Legrand/ Indoasian. |
| 76 | S&F in replacement sheet metal enclosure for MCB DB double door type, single pole and neutral 12 way 240Volts with 200 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed. |
| 77 | Supply and fixing in replacement 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 78 | S&F in replacement MCB Single Pole, 6 to 32 Amps 240 volts, 10KA breaking capacity, convenient to 'C' Curve complete all as specified and directed. |
| 79 | S & F Single pole and neutral enclosure with a two pin and earth plug and socket modular type complete with 20A single pole MCB for AC all as specified and directed |
| 80 | S & F in repair LED light fitting 1x9W/10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.Make- Wipro / Bajaj /Philips |
| 81 | S& F in replacement LED tube light fittings of 20 wattage Aluminium Extruded Body including rawl/plug ,making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr fixed to wall firmly ,complete all as specified and directed. Make- Philips/Bajaj/Wipro |
| 82 | S & F LED panel decorative down light fitting/recess mounted square type white/ warm white 600mm x 600 mm 36W with high out put diffuser 230 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified. .Make: Philips/Syska /Bajaj/Havells |
| 83 | Supply and fix electric water heater, storage type plastic body with stailness steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 84 | M&L for One 3/5 pin socket outlet 15 Amps on independent board but with 4 sqmm copper conductor cable complete with PVC insulated unsheathed, 1100 volts grade (nominal area) FRLSH type multi stranded copper conductor, single core drawn in and including not less than 20 mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring for socket point controlled by one, one way switch, including concealed pressed steel terminal box of required size not less than 2 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer, with 2.8 mm thick top cover of plastic laminated sheet of required colour for mounting switch, sockets, etc including 4 Sqmm FRLSH type PVC insulated unsheathed cable solid copper conductor as continuous earth wire and connected to earth dolly as required at site & including chases cutting & making good disturbed surface & applying finishes to match existing surface complete all as specified and directed. |
| 85 | S & F single pole and neutral enclosure surface mounted 240 volts with 2 pin and earth plug socket with one single pole MCB 20 Amps with indicator of Make: Legrand/Havells/Anchor. |
| 86 | S & F sheet metal enclosure for 8 way SPN MCB DB with suitable rated bus bar double door and neutral link,fixed flush in wall including chases wall for fixing DB and making good disturbed wall surfaces to match with existing specification complete all as specified and directed . |
| 87 | Supply and fixing 240V,10 KA 'C' curve miniature circuit breaker (MCB) SPN having current carrying capacity 63 AMP, in the MCB DB Complete with connection testing and commissioning all as directed and specified. |
| 88 | Supply and fixing 240V,10 KA 'C' curve miniature circuit breaker (MCB) SP having current carrying capacity 10-40 AMP, in the MCB DB Complete with connection testing and commissioning all as directed and specified. |
| 89 | M&L for sub main wiring with PVC insulated 1100V grade FRLS single core multi stranded copper conductor cable of size 2x6 sqmm + 1x6 sqmm as earth continuity cable passing through and including 25/20mm dia PVC conceal conduit all as specified and directed by Engr-in-Charge. Note - Two runs of 6 sqmm & one run of 6 sqmm including PVC conduit shall be measured as unit length. |
| 90 | M&L for laying in fixing on wall GI Pipe 15mm dia medium grade including all fittings and fixtures |
| 91 | S & F PVC connections 15mm size with PTMT nuts of length 450 mm(Set of two) complete all as specified and directed. |
| 92 | S&F fancy type chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe of size 15mm dia |
| 93 | S & F15 mm dia fancy type chromium plated with long shank and angle valve cast copper alloy screwed down type high pressure with cruth or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed.complete all as specified and directed. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |