| 1 | Dismantling posts or struts (wood or R.C.C.) any section, including taking out embedded in concrete including dismantling of barbed wire fixed etc. |
| 2 | Dismantling wrought iron or mild steel work for barbed wire and old chain link fencing obtained from with old RCC or wooden pole ,rolling shutters of any description. |
| 3 | Demolition of Brickwork or stone masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and directed |
| 4 | Demolition of concrete (Unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) |
| 5 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc.50m and making good surface in hard/dense soil. |
| 6 | M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete all as directed by Engr-in-charge |
| 7 | M&L PCC (1:4:8) type D2 using 40 mm graded stone agg as in foundation filling & mass concrete. |
| 8 | M&L for Laterite stone Walling of squared rubble,regular coursed,well bonded,bedded and solidly hearted,built in CM 1:6 complete all as aspecified and directed. |
| 9 | M&L fo Laterite stone Walling of squared rubble,regular coursed,well bonded,bedded and solidly hearted,built in CM 1:6 by using servicable stone obtained Sr Item No 18 here in before ie except stone complete all as specified and directed. |
| 10 | M&L for rendering 15mm thick in cm 1:4 on brick masonary surfaces and finished the even and fair without using extra cement |
| 11 | M & L For PCC type B-1, 1:2:4 (20mm graded stone aggerates) as in coping and the like. |
| 12 | M&L for preparation of new plaster surfaces of wall and applying two coats of cement base paint complete all as specified and as directed by Engineer-in-Charge |
| 13 | M&L for preparation of old plaster surfaces of wall including complete removal washing rubbing and applying two coats of cement base paint complete all as specified and as directed by Engineer-in-Charge (Make : Ist qlty of Acrocem/snowcem plus or equvalent of Narolac or Berger). |
| 14 | S & F rolled mild steel in Joist, channel, angle,flat iron or tee sections Fe 410-W (Gde-E- 250 quality 'A') , fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) |
| 15 | S&F mild steel nuts and bolts not exc.12 mm dia of bolt and not exc. 75mm in length with two washers,one bolt all as specified. |
| 16 | M & L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide on surfacess of any discription, over 10cm in width or girth. |
| 17 | S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured). |
| 18 | S&F 4mm dia galvanised steel wire,(Chain Link PVC Coated) n.exc 100x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed. Note: The dia of galvanised steel wire shall be of 4mm. |
| 19 | Supply and fix mild steel round bars 10mm dia and over, cut to length, bent to shape including cranking, bending, hooping for chain link fencing etc and binding with MS wire not less than 0.9mm dua (annealed) etc complete all as secified and as directed by Engineer-in-charge. |
| 20 | Cutting of bushes/Site clearence up to 1m both sides from the fencing |
| 21 | Removing of surplus spoil/dismantelled material exc. 250 M and n.exc 500 M, depositing where directed at a level n. exc. 1.50 M above the starting level.(hard/dense soil) |
| 22 | M &L for Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening andfixing complete Fe 410 -W (GdeE- 250) quality A |
| 23 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing) |
| 24 | M&L for cement concrete type C2 1:3:6 using 40mm graded stone aggregate 75 mm thick as in base of tiles etc. |
| 25 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete rubber finished paver block of M-35 grade with approved colour, design & pattern as in footparth, parks lawns, drive ways or light traffick parking etc, of rquired strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ labying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed |
| 26 | M&L for Granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20mm thick screed bed in CM 1:4 |
| 27 | M&L for Plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in drains, surface channels and the like including weathering, slightly rounded or chamferred angles and throating as directed and provision of necessary form work complete all as specified and directed. |
| 28 | Extra over serial item No.28 above for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/slopped ends etc complete all as specified and directed. |
| 29 | Supplying and laying of 75mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. |
| 30 | M&L for Hardcore of broken stone or boulder of gauge exc 63 mm but n. exc 100 mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rolled/ rammed to a true surface complete all as specified and directed |
| 31 | M&L 75mm thick 1:3:6 type C-2,(40mm gradded aggregate) PCC in plinth protection finishing cement concrete even and smooth without using extra cement complete all as specified and directed |
| 32 | M&L Cement concrete type B-1,1:2:4 (20mm graded aggregate) 75 mm thick as flooring finished even and smooth complete all specified and directed |
| 33 | M&L for preparation of old surfaces of walls including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including cornices, pilasters etc (plastered or unplastered surfaces) and applying two coat of white (lime) wash complete all as specified. |
| 34 | M & L for preparation of old steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide on surfacess of any discription, over 10cm in width or girth. Please Enable Macros to View BoQ information |