| 1 | Demolition of brick work or stone boulders masonry built in CM including all quins, arches, pillers etc, complete all as specified and directed. |
| 2 | M&L for brick work with Sub class 'B' brick, straight or curved on plan exc 6m mean radius built in CM (1:6), complete all as specified and directed. |
| 3 | M&L for brick work with Sub class 'B' brick, straight or curved on plan exc 6m mean radius built in CM (1:4), complete all as specified and directed. |
| 4 | M&L for brick work with Sub class 'B' brick, straight or curved in plan of any redius in half brick thick wall built in CM (1:4), complete all as specified and directed. |
| 5 | M&L for Pre-cast cement concrete block masonry with solid blocks type C-1 (1:3:6) (20 mm graded aggregate) exc 10 cm in width and setting in mortar (1:6), complete all as specified and directed. |
| 6 | M&L for Pre-cast cement concrete block masonry with solid blocks type C-1 (1:3:6) (20 mm graded aggregate) exc 10 cm in width and setting in mortar (1:4), complete all as specified and directed. |
| 7 | Taking down plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 8 | Material and labour for rendering 15 mm thick on fair faces of brick wall or stone surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete all as specified and directed. |
| 9 | M&L for preparing new surfaces of walls applying two coats of weather proof acrylic exterior paint (100% Acrylic) Base coat of Apex ultima protek duralife or eqvt make and top coat of Apex Ultima protek,or eqvt make Make : Asian Paints) or eqvt make over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings bldgs, complete all as specified and directed. |
| 10 | M&L for preparing old surfaces of walls applying one coat of weather proof acrylic exterior paint (100% Acrylic) Base coat of Apex ultima protek duralife or eqvt make and top coat of Apex Ultima protek,or eqvt make Make : Asian Paints) or eqvt make over a coat of alkali resistent primer through authorized applicator only including use of scaffoldings bldgs, complete all as specified and directed. |
| 11 | S&F Providing precast cement concrete Type B-1, 1:2:4 (20 mm graded aggregate) set in CM 1:4 in landings, cover slabs (for man holes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete with joints to match, complete all as specified and directed. |
| 12 | M&L for Providing, cement concrete 1:2:4 type B-0, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 13 | Dismantling of Trellis work (Jafri), including taking as under of battens in btrellis (posts and rails measured separately), complete all as specified and directed. |
| 14 | S&F for Providing precast cement concrete Type B-0 1:2:4 (12.5 mm aggregate) set in CM 1:4 louvres and jallies, 25mm thick (measured solid), in cluding all mouldings but excluding frame (Pre cast frame shall be measured separately), complete all as specified and directed. |
| 15 | Demolition of Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 16 | Dismantling of wrought iron or mild steel work of any description not otherwise provided, complete all as specified and directed. |
| 17 | Dismantling roof (corrugated, semi corrugated etc) sheets in roof coverings including ridges, complete all as specified and directed. |
| 18 | Excavating in post holes (or similar holes) in soft/loose soil each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good surface, complete all as specified and directed. |
| 19 | M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors, complete all as specified and directed. |
| 20 | S&F for Rolled mild steel sections conforming to Gde Fe-290 (Gde-165-E) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates, complete all as specified and directed. |
| 21 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed. |
| 22 | M&L for preparation of new untreated steel surface of any description exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 23 | Dismantling fencing wire mesh any type any description, complete all as specified and directed. |
| 24 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire, complete all as specified and directed. |
| 25 | Supply only chain link mild steel galvanized fencing, any type or size, complete all as specified and directed. |
| 26 | S&F in repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and directed. |
| 27 | S&F in repair Galvanised, concertina coil of 610 mm dia made of 0.5 mm thick 19 mm wide strip and 2.59 mm dia high tensile wire 125 Nos of clips having 50 Nos of circle and covering 6 running mtr and 5 clips per spiral using a cerntar core of high tensile wire around which a tape of rezor sharp barbes machine crimped etc all as approved, complete all as specified and directed. |
| 28 | M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in plinth protection & similar work including necessary expansion joint filling with bitumen at a certain distance, complete all as specified and directed. |
| 29 | M&L Preparing old painted brick or concrete surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of floor coat emulsion paint, complete all as specified and directed. |
| 30 | M&L preparing new plaster brick or concrete surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of floor coat emulsion paint over a coat priming paints plaster, complete all as specified and directed. Make : INDIGO / Equivalent |
| 31 | Material & Labour for providing and fixing stainless steel (Grade-304) railing, newal post, ends, caps and balustars etc made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size, on the top of floor or the side of waist slab with suitable arrangement incl tanking down existing fittings, complete all as specified and directed. |
| 32 | Demolition of cement concrete (Un reinforced) in ground floor & pavings n.exc 15 cm thickness (below or above GL) and removing debries out side MOD land, complete all as specified and directed. |
| 33 | M&L for M&L 75 mm thick Cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) in hard standing, complete all as specified and directed. |
| 34 | S&F in repair Chequered cement concrete tiles 20cm x 20cm x 25mm thick fixed on CM 1:6 bedding layer of 15mm thick with grey pigment, complete all as specified and directed. |
| 35 | M&L and fixed in repair Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning complete all as specified & directed by Engineer-in-charge.Note :- (i) Pattern of interlocking tile to be rubber moulded or equivalent as approved by GE. (ii) Rate quoted by the contractor shall deemed inclusive of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) packing and finished even and fair to the sides of pavement, sand cushioning, complete all as specified and directed. Please Enable Macros to View BoQ information |