| 1 | Taking down cement plaster of any description on brick or stone walls, ceiling etc including rakking out joints , hacking for key , scrubbing down with water at any height complete all as specified and as directed. |
| 2 | M&L for rendering 10mm thick rendering in cement mortar 1:6 on brick work or concrete surface, surface finished even and fair complete all as specified and as directed. |
| 3 | M&L for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4, mixed with water proofing compound, surface finished even and smooth without using extra cement complete all as specified and as directedNote:-Water proofingcompound shall be measured and paid separately. |
| 4 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 5 | M&L for rendering 5 mm thick on concrete surface in CM 1:3 for ceiling finished even & smooth without using extra cement complete all as specified and as directed. |
| 6 | M & L for preparation of newly plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed. |
| 7 | M&L for preperation newly plastered surfaces and applying two coats of Acrylic distemper over a coat of primer on walls, pillasters, cornices, etc., including applying 3mm thk wall care putty complete all as specified and as directed. |
| 8 | M&L for preperation newly plastered surfaces of wall and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior weather proof paint of required shed (company Depot tinted) with silicon additives @ 1.43 litre / 10 Sqm applied over fully automatic airless spray machine of paint application with a flow speed of minimum 1 Litre per minute having a pressure of 3300PSI. Allow 6-8Hrs to dry the surface in between subsequent coats of paint complete all as specified and directed. complete all as specified and as directed |
| 9 | M&L preparation of for old decorated distempered surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots, washing, rubbing down and stopping of distermpered and painted surfaces and distempering wall by applying one coat of distermper oil emulsion of any tint/ shade with fully automatic airless spray machine of paint application with a flow speed of minimum 1 Litre per minute having a pressure of 3300PSI complete all as specified and as directed. |
| 10 | M&L for preparation of old decorated distempered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots, washing, rubbing down and stopping of distermpered and painted surfaces and distempering wall by applying one coat of distermper oil emulsion of any tint/ shade with fully automatic airless spray machine of paint application with a flow speed of minimum 1 Litre per minute having a pressure of 3300PSI complete all as specified and as directed. |
| 11 | M&L for preparation of decorated old plastered or unplastered surfaces of ceilings by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying two coat of white wash including washing floors, cleaning glass, joinery, electrical fittings wiring etc, of drops and splashes complete all as specified and as directed. |
| 12 | M&L for preparation of old surface of wall and applying a coat of cement based paint complete all as specified and as directed |
| 13 | M&L for complete removal of existing treatment and necessary preparation of surfaces and applying two coats of Acrylic distemper over a coat of primer on walls, pillasters, cornices, etc., including applying 3mm thk wall care putty over old surface complete all as specified and as directed. |
| 14 | M&L for one coat of Aluminium paint ( For chain link fencing ) on surfaces of any description over 10cm width or girth including necessary preparation of surface complete all as specified and as directed. |
| 15 | M&L for two coats of synthetic enamel paint on old painted concrete, plastered surface over 10cm width or girth, not otherwise described including necessary preparation of surface complete all as specified and as directed. |
| 16 | M&L for writing letters or figures (Block, Roman, Italic or Indian) not exceeding 30cm height as directed by Engineer-in-Charge using synthetic enamel paint complete all as specified and as directed. |
| 17 | M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 18 | M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 19 | M&L for one coat of acrylic water based exterior grade primer @0.9litre(undiluted)/10sqm diluted with water in 1:1 ratio to be applied with fully automaic airless spray machine and allow 6-8 hrs to dry the surface for painting of subsequent coats including preparation of old decorated wall surfaces complete all as specified and directed. |
| 20 | M&L for complete removal of existing treatment and necessary preparation of surfaces and applying two coats of100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance, exterior weather proof paint of required shed (company Depot tinted) with silicon additives @ 1.43 litre / 10 Sqm over and applied over a coat of primed surface with fully automatic airless spray machine of paint application with a flow speed of minimum 1 Litre per minute having a pressure of 3300PSI and allow 6-8Hrs to dry the surface in between subsequent coats of paint complete all as specified and directed. |
| 21 | M&L for complete removal of existing treatment and necessary preparation of surfaces and applying two coats of100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance, exterior weather proof paint of required shed (company Depot tinted) with silicon additives @ 1.43 litre / 10 Sqm over and applied over primed surface with fully automatic airless spray machine of paint application with a flow speed of minimum 1 Litre per minute having a pressure of 3300PSI and allow 6-8Hrs to dry the surface in between subsequent coats of paint complete all as specified and directed. |
| 22 | Taking out veeds, small polants/trees over chajjas, roofs, walls at any position and at any situation in ground floor/roof or in 3rd floor roof, ACC roof parapets and making good with cement plaster and surface finish to match existing surface complete all as specified and as directed. |
| 23 | Hacking out old broken glass pane (any thickness , size, quality or description) from steel frame glazed with putty or fixed with beads at any height complete all as specified and as directed. |
| 24 | M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc. 0.5 Sqm in each pane complete all as specified and as directed. |
| 25 | M&L for 3mm thick figured glass ordinary quality and glazing with oil putty in square not exc. 0.5 Sqm in each pane complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 26 | M&L for 3mm thick figured glass ordinary quality and glazing with oil putty in square not exc. 0.5 Sqm in each pane complete all as specified and as directed. Please Enable Macros to View BoQ information |