| 1 | Supplying, replacement, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Ten Loop Panel |
| 2 | Supplying, replacement, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required. |
| 3 | Supplying, replacement, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. |
| 4 | Supplying, replacement, testing & commissioning of intelligent analog addressable photo thermal detector complete with mounting base complete as required. |
| 5 | Supplying, replacement, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 6 | Supplying, replacement, testing & commissioning of addressable fire control module complete as required. |
| 7 | Supplying, replacement, testing & commissioning of addressable horn cum strobe complete as required. |
| 8 | Supplying, replacement, testing & commissioning of addressable manual call point complete as required. |
| 9 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 10 | Cleaning Smoke Detector essentially a vacuum with a soft brush attachment for the surface and compressed air for the internal sensor. |
| 11 | Loop testing is a critical phase in the commissioning and maintenance of a fire alarm system. It ensures that every device on a specific circuit (the loop) is communicating correctly with the control panel and that the wiring integrity is soundOne Loop Please Enable Macros to View BoQ information |