| 1 | M&L for Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6.00m mean radius built in cement mortar (1:6) including demolition of existing brick work complete all as specified and directed. |
| 2 | M&L for Brick work with sub class 'B' bricks (except bricks) straight or curved on plan exc 6.00m mean radius built in cement mortar (1:6) work complete all as specified and directed. |
| 3 | M&L for Rendering 15 mm thick in cement mortar (1:4) using fine sand on brick or concrete surface finish even and fair finishing, curing scaffolding including mixing of water proofing compound and taking down of existing cement plaster etc complete all as specified and directed. |
| 4 | M&L for Rendering 15 mm thick in cement mortar (1:6) using coarse sand on brick or concrete surface finish even and fair finishing, curing scaffolding including taking down of existing cement plaster etc complete all as specified and directed. |
| 5 | M&L for Complete removing of existing treatment from wall / ceilling by using mechanical sander/grinder complete all as specified and directed. |
| 6 | M&L for preparation of old/new surfaces of wall / ceiling and applying two coat weather coat exterior paint complete all as specified and directed (work to be carried upto a height of 7.5m). |
| 7 | M&L for Preparation of old plastered surfaces of walls / ceiling by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of oil emulsion distemper on walls/ceiling using mechanical sander/grinder complete all as specified and directed. |
| 8 | M&L for Preparation of surface of wall / ceilling and applying 1.5mm thick damp proof wall care putty including sanding/grinding complete all as specified and directed. |
| 9 | M&L in repair for DWC (Double wall coruggated) HDPE pipes of size 100mm (ID) confirming to IS 16098 Part-II of strength/stiffness class SN 8 laid in trenches on concrete bed to level/ gadient, jointing as per manufacturers instructions including PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) 75 mm thick for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid as required complete all as specified and directed. |
| 10 | M&L in repair for DWC (Double wall coruggated) HDPE pipes of size 150mm (ID) confirming to IS 16098 Part-II of strength/stiffness class SN 8 laid in trenches on concrete bed to level/ gadient, jointing as per manufacturers instructions including PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) 75 mm thick for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid as required complete all as specified and directed. |
| 11 | M&L in repair for DWC(Double wall coruggated) HDPE pipes of size 200mm (ID) confirming to IS 16098 Part-II of strength/stiffness class SN 8 laid in trenches on concrete bed to level/ gadient, jointing as per manufacturers instructions including PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) 100 mm thick for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid as required complete all as specified and directed. |
| 12 | S&F in repair Factory made heavy duty precast RCC Manhole cover confirming to IS 12592 (Part -1 & II) having clear opening 1200mm x 450 mm x 75mm of M-30 Grade of concrete and suitably reinforced with strong vibrating compaction by vibratory table including providing MS hook duly black painted, complete all as specified and directed. |
| 13 | S&F in repair Factory made Precast plain / perforated RCC Drain/ manhole cover size (900x 450 x 50 mm of M-30 grade of concrete reinforced with 8 mm dia TMT bar of Fe- 500 grade at 150 mm c/c spacing both way with strong vibrating compaction by vibratory table including providing MS hook duly black painted complete all as specified and directed. |
| 14 | S&F in repair Factory made Precast plain / perforated RCC Drain/ manhole cover size (450x 450 x 50 mm of M-30 grade of concrete reinforced with 8 mm dia TMT bar of Fe- 500 grade at 150 mm c/c spacing both way with strong vibrating compaction by vibratory table including providing MS hook duly black painted complete all as specified and directed. |
| 15 | M&L for Removing /uprooting, shrubs, trees, vegetation growth & weeds from the RCC Chajja, roof slabs and around PVC tanks etc and cleaning the complete roof with sweep broom making good the damaged / broken portion with cement mortar in cm 1:4 and finishing the surface fair complete all as specified and directed. |
| 16 | M&L for PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregate) as in foundation of man hole incl demolition of existing cement concrete of any description complete all as specified and directed. |
| 17 | M&L for Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching and forming channels and reforming benching etc complete in PCC 1:2:4 type B1 smooth finish complete 150mm dia & up to 300 mm dia complete all as specified and directed. |
| 18 | M&L for Cleaning the manhole up to 1.50m deep by rodding manually and removing the sludge from manhole and completely cleaning by flushing with water etc complete, sludge shall be buried into ground and covered with the enough quantity of lime to stop the foul smell complete all as specified and directed. |
| 19 | M&L for Cleaning the manhole depth exc 1.50m deep by rodding manually and removing the sludge from manhole and completely cleaning by flushing with water etc complete, sludge shall be buried into ground and covered with the enough quantity of lime to stop the foul smell complete all as specified and directed. |
| 20 | M&L for Cleaning the sewage line up to 150mm dia by rodding manually and removing the sludge and completely cleaning by flushing with water etc complete, sludge shall be buried into ground and covered with the enough quantity of lime to stop the foul smell complete all as specified and directed. |
| 21 | M&L for Cleaning the sewage line over 150mm dia and upto 250mm dia by rodding manually and removing the sludge and completely cleaning by flushing with water etc complete , sludge shall be buried into ground and covered with the enough quantity of lime to stop the foul smell complete all as specified and directed. |
| 22 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n exc. 1.5 m in depth and getting out in soft/loose soil complete all as directed. |
| 23 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25cm complete all as specified and directed. |
| 24 | Removal of surplus soil to distance exceeding 250 metre but n. exc. 500 metre and depositing as directed at a level n. exc. 1.50m above the starting point complete all as specified and directed. |
| 25 | M&L for removing existing water tanks of any description exceeding 250 liters and not exceeding 500 liters capacity, cleaning all Scale dirt etc from tanks and from mouths of circulating pipes including washing with bleaching powder etc reconection and refixing in position with date of cleaning marking with paint complete all as specified and directed |
| 26 | M&L for removing existing water tanks of any description exceeding 500 liters and not exceeding 1000 liters capacity, cleaning all Scale dirt etc from tanks and from mouths of circulating pipes including washing with bleaching powder etc reconection and refixing in position with date of cleaning marking with paint complete all as specified and directed |
| 27 | S&F in repair 1mm thickness of lath Steel rolling shutters, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type. |
| 28 | M&L for capsule pattern fully vitrified coloured tiles Premium quality of Group B I (a) 9 to 10mm thick (Square or rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 complete including dismantling of existing floor tiling including cement mortar bedding and removing rubbish off the premises complete all as directed. |
| 29 | M&L for Non skid fully vitrified coloured tiles Premium quality of Group B I (a) 8 to 9mm thick (Square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 complete including dismantling of existing floor tiling including cement mortar bedding and removing rubbish off the premises complete all as directed. |
| 30 | S&F 15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including taking up or down existing steel tubing pipe complete all as directed. |
| 31 | S&F 20mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including taking up or down existing steel tubing pipe complete all as directed. |
| 32 | S&F Pre-painted colour galvalume aluminium Zinc coating AZ 150 GI based corrugated steel sheet 0.50 mm thick having tensile strength of 550 Mpa as in roof covering/cladding to wall etc fixed in repairs complete all as directed. |
| 33 | S&F Pre-painted colour galvalume aluminium Zinc coating AZ 150 GI based pre profiled (matching with roof sheet) plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, gutter fixed in repairs complete all as directed by Engr-in-charge. |
| 34 | Dismantling existing timber scantling in any position.complete all as specified and directed. |
| 35 | S&F Rolled structural mild steel work as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.(Fe-410-W(Gde E- 250) quality B) |
| 36 | M&L for welded steel wire fabric weight n exc 4kg/sqm fixed/welded to wood or steel members complete all as directed.Note :- Weight of steel wire fabric shall be ascertained by a Board of Officers. |
| 37 | S&F Mild steel framed work such as grills, grating etc with end of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing and similar work complete all as specified and directed. |
| 38 | M&L for Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 39 | S&F 1000 Litres capacity rotational moulded polyethylene water storage tanks, three layered, ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including 20mm dia GI light grade washout pipe 50mm long with plug and 20mm dia GI light grade over flow pipe 600mm long with fitting including 20/25mm dia PTMT ball valve complete set and dismantling of existing unserviceable tank and removing from site complete all as specified and directed |
| 40 | S&F 500 Litres capacity rotational moulded polyethylene water storage tanks, three layered, ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including 20mm dia GI light grade washout pipe 50mm long with plug and 20mm dia GI light grade over flow pipe 600mm long with fitting including 15/20mm dia PTMT ball valve complete set and dismantling of existing unserviceable tank and removing from site complete all as specified and directed |
| 41 | S&F in repair Ball valve 15/20mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball min weight 210 gms fixed in repair complete all as specified and directed. |
| 42 | S&F in repair 15mm GI Elbow/union/socket/Tee (ISI marked) for plumbing complete all as specified and directed. |
| 43 | S&F in repair 15mm GI long screw (ISI marked) for plumbing with all accessories complete all as specified and directed. |
| 44 | M&L for PCC 1:4:8 type D-2, (using 40 mm graded stone agg) as in foundation, filling, mass concrete and sub base of floor including demolition of existing old concrete complete all as specified and directed |
| 45 | M&L for 300x300x25mm heavy duty Chequered cement concrete tile made with rubber moulds of any pattern conforming to IS : 13801 (Latest) decided by Engr-in-charge as in floors/pavings laid over 20 mm thick screed bed 1:6 laid and jointed with white cement slurry mixed with pigment to match the shade of tile complete including dismantling of existing tiles with screed bed of any description and in any position complete all as specified and directed. |
| 46 | M&L for Rubberised precast prepolished coloured concrete Interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade complete with & including 25mm thick sand cushioning layer including dismantling of existing damaged flooring etc complete, all as specified and directed. |
| 47 | M&L for Construction of brick soak well 3.00 m dia and 4.50 m deep, excavation in soft/ loose soil for foundation in PCC 1:3:6 using 40 mm graded stone aggregate, honeycomb brick work in cement mortar 1:4, RCC 1:2:4 type B-1 as in slab, filling with brick bats including necessary earth work complete in repair and all as specified and directed as per TD Drawings. |
| 48 | M&L for 75mm thick PCC 1:3:6 type C-2 using 20 mm graded crushed stone aggregate as in plinth protection or similar places, and finishing the surface even and smooth without using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meters and at every change of direction and filling the same with sealing compound grade 'A' including necessary formwork complete all as specified and directed. |
| 49 | M&L for 40mm thick PCC type B1 1:2:4 (20mm graded crushed stone aggregate) as in floors and finishing the concrete even and smooth using extra cement complete all as specified and directed. |
| 50 | M&L for PCC 1:2:4 Type B-1 {using 20mm graded crushed stone aggregate} as in coping/ benching including weathering, slightly rounded or chamfered angles and throating etc including necessary form work incl demolition of existing cement concrete of any description complete all as specified and directed. |
| 51 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channels and drains including Desludging/ cleaning of open drain of any depth by mechanically means and removing the muck out of IMA premises complete all as specified and directed. |
| 52 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 53 | Dismantling post or post struts (wood steel or RCC) any section, including taking out embedded portion and making good disturbed ground in natural ground. |
| 54 | Excavation in post holes (similar holes) each nexc 0.5cum getting out and removing surplus soil to distance nexc 50m in hard/dense soil. |
| 55 | M&L for PCC 1:2:4 type B2 (using 20 mm graded aggregade) in foundation for post holes. |
| 56 | S & F mild steel joints angle channel or tee section and fix independently in concrete as fencing post and similar works congorming to Fe 290 Gde E- 165 |
| 57 | S & F mild steel screw bolts purpose made with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed to be fitted with washers and one hexagonal or square nut. |
| 58 | S&F in repair PVC coated MS galvanised chain link fencing of weight not less than 4.0 kg/sqm, PVC coating of 1.5mm and mesh size of 50 x 50mm of any type of standard rail straining bolts etc aperture and dia as decided by Engineer-in-charge. |
| 59 | M&L for MS round bars 10mm dia & over cut to length bent to shape required incl cranking bending spirally for hoping for colm and backing ends and binding with & include MS wire (a headed) not less than 0.9mm dia or securing with clips quality confirming to Fe-410W. |
| 60 | M&L for Cleaning of septic Tanks/ Soakage well/ Man holes of any capacity mechanically by using mobile high pressure super sucker machine (Honey sucker) consisting of a sludge tank, a high pressure water jet pump and a high flow jetting blower or vaccum pump for suction and each trip shall clean minimum 6 cum of sludge including diluted liquid. Pumping out sewage water, accumulated Night soil, sludge's, (both solid and liquid) and other obstructive material into dump tank and removing to outside of Defence land immediately for disposal, re-fixing the cover after complete cleaning complete all as specified and directed.Note :- 1. After removal of the sludges from the pits, the septic tanks/ soakage well/ man holes to be cleaned throughly with water.2. Utmost Care shall be taken to maintain hygenic condition while removing sludge/ foul materials to outside of defence land. |
| 61 | M&L for removing/cleaning of debris of any type from IMA premises to outside of Defence land by using tractor trolley and each trip shall clean minimum 3 cum of material complete all as specified and directed. Please Enable Macros to View BoQ information |