| 1 | Demolition of brick work or stone masonry, built in cement mortar including all quoins arches, pillar etc. but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed. |
| 2 | M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan, exceeding 6 metre mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 3 | All as per serial item No. 2.00 here-in-above but except stone. |
| 4 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4, complete all as specified and directed. |
| 5 | All as per serial item No. 4.00 here-in-above but except stone. |
| 6 | M&L for flush pointing to random rubble, uncoursed or brought upto course on stone masonry or concrete block walling in cement mortar 1:4, complete all as specified and directed. |
| 7 | Taking down cement plaster of any description on brick work or stone masonry or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 8 | M&L for 15mm thick rendering into two layers consisting 10mm thick in CM 1:4 followed by 5mm thick in CM 1:4 with using WPC on fair faces of brick work or concrete surface including finishing the surface even and fair without using extra cement, complete all as specified and directed.Note :- WPC shall be measured and paid separately under respective item of this BOQ. |
| 9 | M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistance primer, complete all as specified and directed. |
| 10 | M&L for preparation of plastered or un-plastered or old decorative surfaces of walls and washing down, brooming down or steel wire brushing etc. and applying one coat of cement base paint, complete all as specified and directed. |
| 11 | M&L for preparation of plastered or un-plastered old decorative surfaces, washing down, brooming down or steel wire brushing etc. and applying one coat of first quality exterior grade wheather proofing acrylic emulsion paint paint on walls, complete all as specified and directed. |
| 12 | Taking down eaves, gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks, etc including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fitting and accessories), complete all as specified and directed. |
| 13 | S&F 110mm bore PVC (SWR) pipes single, socketed in any length with rubber ring joints, fixed to walls with MS clamps of suitable size, complete all as specified and directed. |
| 14 | All as per serial item No. 13.00 here-in-above but refixing only (except pipe) but inclusing MS clamp of suitable size, complete all as specified and directed. |
| 15 | S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed. |
| 16 | S&F 110mm bore PVC (SWR) bends with access door, any radius, complete all as specified and directed. |
| 17 | Demolition of cement concrete (un-reinforced) as in ground floor and paving, not exe 15cm thickness (below or above ground level), complete all as specified and directed. |
| 18 | M&L for 75mm thick PCC 1:4:8 type D-1 (using 20mm graded crushed stone aggregates) as in sub base, complete all as specified and directed. |
| 19 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling in and mass concrete, complete all as specified and directed. |
| 20 | M&L for plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in foundation for fencing post, filling in and mass concrete, complete all as specified and directed. |
| 21 | M&L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in coping including necessary formwork and weathering, slightly rounded or chamfered and treading, complete all as specified and directed. |
| 22 | S&F cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in louvres and jallies, 25mm thick (measured soiled) including all moulding but coping and including necessary formwork, complete all as specified and directed. |
| 23 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in surface channels and drains, complete all as specified and directed. |
| 24 | M&L for plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in coping, kerbing etc including all necessary formworks including weathering, slightly rounded or chamfered and treading, complete all as specified and directed. |
| 25 | Providing precast cement concrete 1:2:4 in road side kerb stone etc (of any section indicated) with plain fair faces including chamfers, weathering, throating etc and setting in cement mortar 1:4, complete with joints to match as directed by Engr-in-Charge. |
| 26 | M&L for preparation of new concrete surfaces / plastered surface of any description over 10cm girth or width not otherwise described and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed. |
| 27 | M&L for preparation of old concrete surfaces / plastered surfaces of any description over 10cm girth or width, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 28 | Demolition of stone slabs and tiles of any description or thickness as in floors, aprons etc, laid, bedded and pointed in any mortar, complete all as specified and directed. |
| 29 | S&F factory made, heavy duty, full body digital paving coloured tiles of size 300mm x 300mm x 10mm thick each, for external use, laid over and including 15mm thick screed bed or bedding layer in CM 1:4 including jointed with neat cement slurry and pointed in coloured tile grout to match the shade of tiles, complete all as specified and directed. |
| 30 | M&L for machine pressed rubber moulded, manufactured/ compacted by vibrating table method precast concrete interlocking paver block of any shape and size, confirming to IS:15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment and joints filled with sand, complete all as specified and directed. |
| 31 | All as per serial item No. 30.00 here-in-above but except tiles/ paver blocks including dismantling. |
| 32 | M&L for machine pressed rubber moulded, manufactured/ compacted by vibrating table method precast concrete interlocking paver block of any shape and size, confirming to IS:15658-2006 of 80mm thickness, M-40 grade with grey cement and pigment and joints filled with sand, complete all as specified and directed. |
| 33 | All as per serial item No. 32.00 here-in-above but except tiles/ paver blocks including dismantling. |
| 34 | M&L for sand filling under floors, paver or in foundation including watering and consolidation, complete all as specified and directed. |
| 35 | Dismantling of posts or struts (wood, steel or RCC) embeded in concrete of any section including taking out embedded portion and making good disturbed ground, complete all as specified and directed. |
| 36 | Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation etc. or for shafts, manholes, pier holes etc not exc 10 Sqm on plan and not exc 1.50 mtr in depth and getting out in any type of soil, complete all as specified and directed. |
| 37 | Excavating in post holes (or similar holes), not exc 0.50 Cum each, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm thick in hard/ dence soil, complete all as specified and directed. |
| 38 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed. |
| 39 | Removing excavated material to a distance exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point, complete all as specified and directed. |
| 40 | Demolition and breaking up drain pipes AC / RCC / SGSW / HDPE DWC Pipe line etc. of any dia of pipe upto 200mm dia, complete all as specified and directed. |
| 41 | M&L for HDPE DWC (double wall corrugated) pipes confirming to IS-16098 of 170mm internal dia pressure ratting SN--08 fixed with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc, single 'Y' 'Jn complete as required, fixed as per manufacturer's instructions, laid in trenches for sewage pipe line, complete all as specified and directed. |
| 42 | Dismantling of structural steel work of any description, complete all as specified and directed. |
| 43 | Dismantling of mild steel barbed wire of any description not otherwise provided for, complete all as specified and directed. |
| 44 | M&L for mild steel framed work for grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, conforming to Fe-290 Gde-E-165, complete all as specified and directed. |
| 45 | M&L for mild steel work for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work, conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 46 | S&F 3.15mm dia plain mild steel wire, galvanised class 3, in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins etc, complete all as specified and directed.Note :- Each line of wire to be measured. |
| 47 | S&F in repairs/ replacement of galvanised 2 strand steel barbed wire, 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc, complete all as specified and directed. |
| 48 | Supply only chain link fencing galvanised mild steel wires 3mm dia, mesh size not less than 50mm x 50mm, complete all as specified and directed. |
| 49 | Fixing only chain link fencing including line wires wearing alternate mesh, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified and directed. |
| 50 | S&F mild steel bolts, purpose made with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 30cm long and dia of neck exceeding 12mm but not exceeding 20mm, complete all as specified and directed. |
| 51 | M&L for preparation of new or previously untreated steel or iron surface of any description, exc 10cm with or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. |
| 52 | Dismantling of water tank of capacity exceeding 250 ltrs but not exceeding 500 ltrs and removing to store, complete all as specified and directed. |
| 53 | Dismantling of water tank of capacity exceeding 500 ltrs but not exceeding 1000 ltrs and removing to store, complete all as specified and directed. |
| 54 | Dismantling of water tank of capacity exceeding 1000 ltrs but not exceeding 2000 ltrs and removing to store, complete all as specified and directed. |
| 55 | M&L for 500 ltrs capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), three layered, white in colour (inside & outside), hoisted and fixed in position including inlet, outlet and overflow connection including nipples of suitable size, complete all as specified and directed. |
| 56 | M&L for 1000 ltrs capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), three layered, white in colour (inside & outside), hoisted and fixed in position including inlet, outlet and overflow connection including nipples of suitable size, complete all as specified and directed. |
| 57 | M&L for 2000 ltrs capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), three layered, white in colour (inside & outside), hoisted and fixed in position including inlet, outlet and overflow connection including nipples of suitable size, complete all as specified and directed. |
| 58 | Disconnection of existing tank, setting side for repairing, cleaning etc. and hoisting after cleaning and removing all scale and dirt etc. from tank and from mouth of circulating pipe etc. of capacity exc 500 ltrs but not exc 1000 ltrs including endorsed the words 'CLEANED ON WITH DATE' with white synthetic enamel paint including replacement of broken/ unserviceable fitting such as elbow, Tea, socket, nipple of any size etc, complete all as specified and directed. |
| 59 | Disconnection of existing tank, setting side for repairing, cleaning etc. and hoisting after cleaning and removing all scale and dirt etc. from tank and from mouth of circulating pipe etc. of capacity upto 500 ltrs including endorsed the words 'CLEANED ON WITH DATE' with white synthetic enamel paint including replacement of broken/ unserviceable fitting such as elbow, Tea, socket, nipple of any size etc, complete all as specified and directed. |
| 60 | Disconnection of existing tank, setting side for repairing, cleaning etc. and hoisting after cleaning and removing all scale and dirt etc. from tank and from mouth of circulating pipe etc. of capacity exc 1000 ltrs but not exc 2000 ltrs including endorsed the words 'CLEANED ON WITH DATE' with white synthetic enamel paint including replacement of broken/ unserviceable fitting such as elbow, Tea, socket, nipple of any size etc, complete all as specified and directed. |
| 61 | S&F ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for 20mm bore iron pipe and fixed in position, complete all as specified and directed. |
| 62 | S&F ball brass valve of 25mm dia high pressure with polythene float and fly nut, complete all as specified and directed. |
| 63 | Taking up or down 15mmm bore water steel tubing and connections including cleaning for refixing or removal to store, complete all as specified and directed. |
| 64 | Taking up or down 20mmm bore water steel tubing and connections including cleaning for refixing or removal to store, complete all as specified and directed. |
| 65 | Taking up or down 40mmm bore water steel tubing and connections including cleaning for refixing or removal to store, complete all as specified and directed. |
| 66 | M&L for 15mm bore steel water tubing 'medium grade' galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed. |
| 67 | All as per serial item No. 66.00 here-in-above but except pipe. |
| 68 | M&L for 20mm bore steel water tubing 'medium grade' galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed. |
| 69 | All as per serial item No. 68.00 here-in-above but except pipe. |
| 70 | M&L for 40mm bore steel water tubing 'medium grade' galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed. |
| 71 | All as per serial item No. 70.00 here-in-above but except pipe. |
| 72 | M&L for cutting chases in stone wall / concrete block walls / slab, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends of edges of landing steps, cills, sunshed, shelves, lintels etc and cutting chease for water tubing etc. and making good to distrubed surface with CM or CC, cutting not exc 10cm in girth, complete all as specified and directed. |
| 73 | Dismantling of timber scantlings, 40 Sqcm and over in section, in any position, complete all as specified and directed. |
| 74 | M&L for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, confirming to Fe-410-W (Gde-E-250 Quality 'A'), complete all as specified and directed. |
| 75 | Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and directed. |
| 76 | S&F 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour, having tensile strength of 550 Mpa as in roof coverings / cladding to walls, fixed with self tapping screws, complete all as specified and directed. |
| 77 | S&F 0.50mm thick pre-painted glavalume aluminium zinc coating GI based plain steel sheet of any colour, having tensile strength of 550 Mpa as in roof coverings / cladding to walls, fixed with self tapping screws, complete all as specified and directed. |
| 78 | Dismantling of ceiling boards, fiber pulp, insulation etc. or insulation board / slabs / blankets of any thickness including cover and MS Tee grid, complete all as specified and directed. |
| 79 | S&F false ceiling non asbestos fibre cement board ceiling 4mm thick, size of panel 600mm x 600mm, designed ceiling, conforing to IS-12862 to 14862 type B in true horizontal level, suspended on interlocking metal grid dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main ‘T’ runner with suitably spaced joints to get required length and 15mm x 32mm made of 0.30mm sheet and cross at 600mm c/c to from grid including required cutting/ making, opening for servies like diffusers, grills, light fittings, fixures, socket, detectors etc. Main ‘T’ runners to be suspended from ceiling using GI soffit cleats fixed existing rafter, purlin etc with galvanised butterfly clips, spaced at 1200mm c/c along a min T, bottom exposed width of 15mm all T-sections shall be centra black pre-painted with polyester paint and having a load bearing capacity of 12 kg/Sqm and fixed all exesting electric wiring and fixtures all complete at any height, complete all as specified and directed. |
| 80 | S&F false ceiling boards of Everest Fibre Cement Designer tile, white painted (High Pressure Steam Cured) of 4mm thickness (as per IS-14862) of size 1220mm x 1220mm / 1195mm x 595mm / 1220mm x 610mm or any other suitable size as per existing grid frame work and any one of the design (occeanic, lake & hill, cascade or electra) in true horizontal level, suspended on existing inter locking metal grid including required cutting/ making opening for services like fixed over existing grid inluding necessary scaffolding etc. and refixing all exesting electric wiring and fixtures all complete at any height, complete all as specified and directed. |
| 81 | All as per serial item No. 80.00 here-in-above but except ceiling board including removing and refixing existing board. |
| 82 | S&F grid frame suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main 'T' runner with suitably spaced joints to get required length and 15x32mm made of 0.30mm sheet and cross 'T' at 600mm c/c to from a grid including required cutting/ making, opening for services like diffusers, grills, light fittings, fixures, smoke detectors etc. Main 'T' runners to be suspended from ceiling using GI soffit cleats fixed to existing rafter, purlin etc. with gavanised butterfly level clips, spaced at 605mm x 605mm c/c along main T, bottom exposed width of 15mm of all 'T' sections shall be centra black prepainted with polyester paint, and having a load bearing capacity of 12 Kg/Sqm and refixed all existing electric wiring and fixtures all complete at any height, complete all as specified and directed. |
| 83 | M&L for 75mm thick cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to receive floor rough finishes, complete all as specified and directed. |
| 84 | Dismantling of floor, hearth or wall tling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 85 | M&L for non skid ceramic coloured tiles of 7 to 8mm thick (square / rectangular), area of each tile exc 0.11 Sqm but not exc 0.18 Sqm as in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid/ fixed over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 86 | M&L for non skid ceramic coloured tiles of 7 to 8mm thick (square / rectangular), area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in floor, skirtings etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid/ fixed over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 87 | M&L for coloured glazed ceramic tiles of each size 450x300x7mm as on vertical surfaces of walls, dados, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4, complete all as specified and directed. |
| 88 | M&L for coloured vitrified (double charged) tiles10mm thick (Square / rectangular), polished, light shade, area of each tile exceeding 0.38 Sqm but not exc 0.64 Sqm (min size 1200mm x 600mm) as in floor, skirtings etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid/ fixed over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 89 | All as per serial item No. 88.00 here-in-above but as in skirting to match, fixed over and including 10mm thick rendering in cement mortar 1:3. |
| 90 | M&L for 25mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in floor base of tiles, complete all as specified and directed. |
| 91 | M&L for coloured glazed ceramic tiles of size 600mm x 300mm x 7mm thick each or above nearest sizes as on vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 10mm screed bed in CM 1:3, complete all as specified and directed. |
| 92 | Demolition of stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness as in floors, aprons etc, complete all as specified and directed. |
| 93 | M&L for machine cut kota stone slab flooring, 18-20mm thick as in floor, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, laid/ fixed over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 94 | All as per serial item No. 93.00 here-in-above but as in skirting, dados etc. |
| 95 | M&L for 18-20mm thick marble strip, cut to width not exc 100mm wide, fixed as border in floor, stair case, walk ways etc. including rubbing and polishing complete, laid/ fixed over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 96 | S&F reflective chequered ceramic tiles of size 30cm x 30cm x 9-10mm thick each with grey cement and pigments, set, jointed and pointed in neat cement slurry as in floors, laid/ fixed over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 97 | M&L for red/ black granite (of any type) stone slab 16mm thick, machine cut as in window cill / counter top slab, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing with rounding to edges of stone slabs one edge complete, fixed over and including 10mm thick backing coat in CM 1:4, complete all as specified and directed. |
| 98 | Checking of plumbing work, mason work and joinery (wooden/ steel) iron/ aluminium mongery, pelmet box, door springs etc. requiring carpentry/ plumbing/ mason work and carrying out minor repairs such as tightening of screws/ nails, minor adjustment of joinery, door/ windows, water taps, stop cocks, water tank, water supply pipe line etc. by means of planer/ chiesling etc. including petty repairs material like screws/ nails, plug, cement, sand, aggregate etc. to make it functional, complete all as specified and directed.Notes :- (a) Any items required to be replaced shall be paid under respective items and in that case this items shall not be measured and paid. (b) The contractor or his authorised rep shall collect the complaint of all carpenter work from complaint cell / JE-in-Charge/ Engr-in-Charge daily and all complaint will be rectified by the contractor within the same day then the returned the complaint slip after completion of complaint and get recipt from concered JE/Engr-in-charge. If he fails to complete the work within same day then a recovery will be made @ Rs. 250.00 per day per complaint. S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. Please Enable Macros to View BoQ information |