| 1 | Taking down carefully existing surface / concealed unserviceable aluminum/ copper point wiring (light, fan, socket, power or sunken box) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets, bracket holder, boards light fittings etc. and making good to disturbed surfaces of walls, floors, ceilings etc. where required and finished the existing surfaces after complete of new point wiring, complete all as specified and directed. |
| 2 | M&L for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multistranded copper conductor cable 1100 volts grade single core including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in & including PVC concealed 25mm dia medium grade with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drawn in to and including surface PVC rigid non metalic conduit controlled by one switch including PVC sheet metal flush boxes of anyway (as per site requirement) for mounting switches, sockets, regulators etc for fixing one light / fan / bell / fan / exhaust fan point and making good disturbed surfaces to match with the existing surface, complete all as specified and directed. |
| 3 | All as per serial item No. 2.00 here-in-above but one light point, controlled by two way switch. |
| 4 | All as per serial item No. 2.00 here-in-above but one 5 Pin, 6 Amp socket outlet on same board. |
| 5 | All as per serial item No. 2.00 here-in-above but one 5 Pin, 6 Amp socket outlet on independent board. |
| 6 | All as per serial item No. 2.00 here-in-above but for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 2.5 Sqmm, drawn through in and including PVC conduit size of not less than 25mm concecled in wall / surface. |
| 7 | S&F switch one way 5/6 Amp, complete all as specified and directed. |
| 8 | S&F switch piano flush type for bell push 5 Amp, complete all as specified and directed. |
| 9 | S&F socket, 6 Amps, 2 in 1, 3/5 pin, complete all as specified and directed. |
| 10 | S&F switch socket combined piano, 2 in 1 type, 6 Amp, flush type, complete all as specified and directed. |
| 11 | S&F switch socket combined with box piano 2 in 1 type 6 Amp flush type, complete all as specified and directed. |
| 12 | S&F switch socket combined piano type 6 pin 15/16 Amps flush type, complete all as specified and directed. |
| 13 | S&F switch socket combined with box piano type 6 pin 15/16 Amps flush type, complete all as specified and directed. |
| 14 | S&F angle lamp holder, insulated body with back plate for batten fitting, complete all as specified and directed. |
| 15 | S&F ceiling rose PVC / polycarbonate isolated body, three terminal, AC 230 volts, complete all as specified and directed. |
| 16 | S&F electic bell (ding dong) AC, 230/250 Volts grade, single pole, complete all as specified and directed. |
| 17 | S&F stepped type electronic fan regulator, flush type on the existing phenolic laminated sheets etc as per site requirement, complete all as specified and directed. |
| 18 | S&F fan capacitor of any capacity, complete all as specified and directed. |
| 19 | S&Fpolycarbonate plug top 3 pin 5 Amps, complete all as specified and directed. |
| 20 | S&F polycarbonate plug top, 3 pin 15/16 Amps, complete all as specified and directed. |
| 21 | S&F modular switch single pole one way, 6 Amps 240 volts with polycarbonate body, complete all as specified and directed. |
| 22 | S&F modular socket 6 Amps 5 pin flush type, 240 volts with polycarbonate body, complete all as specified and directed. |
| 23 | S&F modular socket outlet 5 pin 6/15 Amps multipurpose 2 in 1 flush type, 240 volts with polycarbonate body, complete all as specified and directed. |
| 24 | S&F modular switch single one way 16 Amps 240 volts with polycarbonate body, complete all as specified and directed. |
| 25 | S&F modular switch single pole, two ways, 6 Amps 240 volts with polycarbonate body, complete all as specified and directed. |
| 26 | S&F modular electronic fan regulator, step type, two module, 240 volts AC and making all necessary connection, complete all as specified and directed. |
| 27 | S&F modular white cover plate with frame, 2 module, complete all as specified and directed. |
| 28 | S&F modular white cover plate with frame, 3 module, complete all as specified and directed. |
| 29 | S&F modular white cover plate with frame, 6 module, complete all as specified and directed. |
| 30 | S&F modular white cover plate with frame, 8 module, complete all as specified and directed. |
| 31 | S&F modular white cover plate with frame, 12 module, complete all as specified and directed. |
| 32 | S&F in replacement of modular metal flush box with 1.2mm thick, 2 module, flushing mounting in the wall for fitting cover plate with frame on switchs / sockets, complete all as specified and directed. |
| 33 | S&F in replacement of modular metal flush box with 1.2mm thick, 3 module, flushing mounting in the wall for fitting cover plate with frame on switchs / sockets, complete all as specified and directed. |
| 34 | S&F in replacement of modular metal flush box with 1.2mm thick, 6 module, flushing mounting in the wall for fitting cover plate with frame on switchs / sockets, complete all as specified and directed. |
| 35 | S&F in replacement of modular metal flush box with 1.2mm thick, 8 module, flushing mounting in the wall for fitting cover plate with frame on switchs / sockets, complete all as specified and directed. |
| 36 | S&F in replacement of modular metal flush box with 1.2mm thick, 12 module, flushing mounting in the wall for fitting cover plate with frame on switchs / sockets, complete all as specified and directed. |
| 37 | S&F 3mm thick plastic laminated hylem sheet cover of size 200mm x 150mm including cutting / finishing or making hole for mounting of switches, sockets, regulators etc, complete all as specified and directed. |
| 38 | S&F 3mm thick plastic laminated hylem sheet cover of size 250mm x 200mm including cutting / finishing or making hole for mounting of switches, sockets, regulators etc, complete all as specified and directed. |
| 39 | S&F 3mm thick plastic laminated hylem sheet cover of size 125mm x 250mm including cutting / finishing or making hole for mounting of switches, sockets, regulators etc, complete all as specified and directed. |
| 40 | S&F 3mm thick plastic laminated hylem sheet cover of size 125mm x 175mm including cutting / finishing or making hole for mounting of switches, sockets, regulators etc, complete all as specified and directed. |
| 41 | M&L for sub main wiring with two single core 4.0 Sqmm FRLS copper conductor PVC insulated and unsheathed cable induding PVC conduit medium grade (appropriate size), concealed in wall for sub main connection including single core 4.0 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete including taking down old sub main wiring, complete all as specified and directed. Note :- Two runs of 4.0 Sqmm FRLS copper conductor for Phase & Neutral and one run of 4.0 Sqmm FRLS copper conductor for earthing shall be measured as one unit length. |
| 42 | M&L for sub main wiring with two single core 6.0 Sqmm FRLS copper conductor PVC insulated and unsheathed cable induding PVC conduit medium grade (appropriate size), concealed in wall for sub main connection including single core 6.0 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete including taking down old sub main wiring, complete all as specified and directed. Note :- Two runs of 6.0 Sqmm FRLS copper conductor for Phase & Neutral and one run of 6.0 Sqmm FRLS copper conductor for earthing shall be measured as one unit length. |
| 43 | M&L for sub main wiring with two single core 10.0 Sqmm FRLS copper conductor PVC insulated and unsheathed cable induding PVC conduit medium grade (appropriate size), concealed in wall for sub main connection including single core 6.0 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete including taking down old sub main wiring, complete all as specified and directed. Note :- Two runs of 10.0 Sqmm FRLS copper conductor for Phase & Neutral and one run of 6.0 Sqmm FRLS copper conductor for earthing shall be measured as one unit length. |
| 44 | S&F VTPN DB 4 way, suitable for Mounting MCB as incomer of rating 160 Amps with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with MCCB & MCB as required and taking down of old unservicable DB, complete all as specified and directed. |
| 45 | S&F in replacement of MCB distribution board SPN, 240 Volts, 12 Way with 100 Amp rated bus bar having IP-43 protection and double metal door, concealed in wall including connection with MCBs, complete all as specified and directed. |
| 46 | S&F in replacement of MCB distribution board SPN, 240 Volts, 8 Way with 200 Amp rated bus bar having IP-43 protection and double metal door, concealed in wall including connection with MCBs, complete all as specified and directed. |
| 47 | S&F in replacement of MCB distribution board SPN, 240 Volts, 4 Way with 100 Amp rated bus bar having IP-43 protection and double metal door, concealed in wall including connection with MCBs, complete all as specified and directed. |
| 48 | S&F in replacement of metal clad plug & socket DB with MCBs single pole enclosere with a three pin earth plug and socket suitable for 20 Amp complete with one single pole MCB 20 Amp, complete all as specified and directed. |
| 49 | S&F in replacement of MCCB 100 Amps, 16 KA, 4 Pole including electrical connection, complete all as specified and directed. |
| 50 | S&F in replacement of MCCB 125 Amps, 16 KA, 4 Pole including electrical connection, complete all as specified and directed. |
| 51 | S&F in replacement of MCB SPN 40 to 63 Amps, 240 Volts, 'C' curve, 10 KA, complete all as specified and directed. |
| 52 | S&F in replacement of MCB SPN 32 Amps, 240 Volts, 'C' curve, 10 KA, complete all as specified and directed. |
| 53 | S&F in replacement of MCB SP 10 to 32 Amps, 240 Volts, C' curve, complete all as specified and directed. |
| 54 | S&F in replacement of INVERTER LED batten light fitting 4 feet, 20 Watt, 220 Volts, AC, long-lesting Li-ion battery including connecting up with two core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 55 | S&F in replacement of LED light fitting 4 feet, 20 Watt, 220 Volts, AC, batten type with driver holder including connecting up with two core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 56 | S&F in replacement of LED light fitting mirror type with high output diffuser, 2 feet, 10 Watt 220 Volts, AC, batten type with driver holder including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. |
| 57 | S&F in replacement of LED light fitting mirror type with high output diffuser, 1 feet, 5 Watt, 220 Volts AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 58 | S&F in replacement of LED street light fitting 35 Watt, 230 Volts AC, outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant complete with IP-65 protection complete for building secuity purpose including 20/25mm bore Gl light grade pipes not less than 1.0 mtr long, bend to shape including MS clamps of suitable size, nuts, bolt & washers, complete all as specified and directed. |
| 59 | S&F in replacement of 30/35 Watt LED flood light, 230 Volts AC, outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamps, complete all as specified and directed. |
| 60 | S&F in replacement of LED bulk head fitting of 9/10 Watt, surface mounting type, exturded polycarbonate body with diffuser complete with testing, complete all as specified and directed. |
| 61 | S&F in replacement of LED fitting luminaire 600mm x 600mm size, 35/36 Watt, 230/240 Volts AC with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp, suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed. |
| 62 | S&F in replacement of LED light fitting of 8/12 Watt, Sqaure/ Round alpha panel cool day white, suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete, complete all as specified and directed. |
| 63 | S&F LED rope light for indoor and outdoor for bright and uniform glow. This LED rope light features an AC strip light that provides superior light output and rope light is easy to install and customize as it can be cut to size and bent into any shape or pattern to suit for need, complete all as specified and direcetd. |
| 64 | S&F 10 watt LED garden light fitting, pressure die cast powder coated housing with PC diffuser. Efficient high output LED with IP-65 protection, decorative bollard type with opal diffuser and aluminium reflector complete with all including taking down old/UNSV garden light fitting of any type & wattage, complete all as specified and directed. |
| 65 | S&F decorative Post Top for indirect light with IP-65 protection. Resistant to impact and corrosion. Glare free and better uniformity. LED gate light fitting of 20 Watts, 240 Volts, driver duly brewired up to terminal on firms, suitable for pole of dia 40-75mm in built electronic driver complete including taking down old/UNSV gate light fitting, complete all as specified and directed. |
| 66 | S&F exhaust fan, steel body, AC single phase 230 Volts of size 380mm sweep with blades, frame and lovers, complete all as specified and directed. |
| 67 | S&F exhaust fan, steel body, AC single phase 230 Volts of size 300mm sweep with blades, frame and lovers, complete all as specified and directed. |
| 68 | S&F in replacement of plastic body white exhaust fan of size 150mm sweep and connecting, complete all as specified and directed. |
| 69 | S&F in replacement of plastic body white exhaust fan of size 200/250mm sweep and connecting, complete all as specified and directed. |
| 70 | Supply & Laying cable 1.5 Sqmm 3 Core round aluminium wires, ISI Marked wire, good quality PVC coating and good grade aluminium conductor, material is used which makes it suitable for indoor/outdoor requirement, complete all as specified and directed. |
| 71 | Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip, electric power cables (heavy duty) with aluminium conductor of size 10 Sqmm 2 Core, 1100 Volts grade including cable glands, lugs, saddling on wall (if required), nuts, bolts and washers of suitable size including taking out old unserviceable cable, complete all as specified and directed. |
| 72 | Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip, electric power cables (heavy duty) with aluminium conductor of size 16 Sqmm 2 Core, 1100 Volts grade including cable glands, lugs, saddling on wall (if required), nuts, bolts and washers of suitable size including taking out old unserviceable cable, complete all as specified and directed. |
| 73 | Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip, electric power cables (heavy duty) with aluminium conductor of size 25 Sqmm 3.5 Core, 1100 Volts grade including cable glands, lugs, saddling on wall (if required), nuts, bolts and washers of suitable size including taking out old unserviceable cable, complete all as specified and directed. |
| 74 | S&F 25mm bore GI tubing light grade with all fittings, laid across road in trenches or across PCC drain, alongwith electric pole or floor/wall for cable protection with suitable size of MS clamps, nuts and bolts/washer including taking up/down existing pipe, complete all as specified and directed. |
| 75 | S&F 50mm bore GI tubing light grade with all fittings, laid across road in trenches or across PCC drain, alongwith electric pole or floor/wall for cable protection with suitable size of MS clamps, nuts and bolts/washer including taking up/down existing pipe, complete all as specified and directed. |
| 76 | M&L for dry river sand as in cushioning to underground cables, provided with a layer of sand 8cm thick before laying the cable and 15cm thick after laying the cable and stretching the cable, complete all as specified and directed.Note :- Only punned and consolidated volume to be measured. |
| 77 | M&L for un-reinforced precast concrete cable cover class LV, type-1, flat of size 250mm x 150mm x 40mm for cable protection, complete all as specified and directed. |
| 78 | Excavation in trenches, exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation, electric pole, laying of UG cables/ pipes etc. and getting out in any type of soil, complete all as specified and directed. |
| 79 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed. |
| 80 | Removing excavated material to a distance exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point, complete all as specified and directed. |
| 81 | M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick, burried directly into the ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to Gl earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3, connected to earthing test point all as specified or indicated including excavation and connected earth work, PCC chamber and cover, watering pipe, funnel wire mesh but with earth lead protection pipe and test on completion after dismantling unserviceable erthing (above GL only) including dismantling of existing earthing, complete all as specified and directed. Note :- On testing after completion if desired earth resistence is not obtained, the earthing will be redone at no extra cost. S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. Please Enable Macros to View BoQ information |