| 1 | =B2& \\" BoQ\\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE(I) R&D RCI HYDERABAD Name of Work: REPAIRS/ CLEANING TO MANHOLES, REMOVING ALL BLOCKAGES OF SANITARY FITTINGS, SEWAGE LINES, SEPTIC TANKS AND MISC WORKS AT ZONE-I OF TECH AREA AT RCI HYDERABAD UNDER GE (I) R&D RCI HYDERABAD Contract No: GE(I) RCI/HYD/ OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SlNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic Rate In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount With Taxes Total Amount In Words |
| 2 | Dismantling of reinforced concrete drain pipes 200mm bore internal dia jointed in cement mortar and taking out of trenches complete all as specified and as directed by the Engineer-in-Charge |
| 3 | Supply and laying 200 mm bore reinforced concrete pipe of Class NP-2, with collars, laid and jointed complete all as specified and as directed by the Engineer-in-Charge. |
| 4 | M&L for plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) bed to drain pipes including packing under and haunching aganist the sides of pipes of 200mm bore after they are laid and tested complete all as specified and as directed. |
| 5 | Dismantling of reinforced concrete drain pipes 300mm bore internal dia jointed in cement mortar and taking out of trenches complete all as specified and as directed by the Engineer-in-Charge |
| 6 | Supply and laying 300 mm bore reinforced concrete pipe of Class NP-2, with collars, laid and jointed complete all as specified and as directed by the Engineer-in-Charge. |
| 7 | M&L for plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) bed to drain pipes including packing under and haunching aganist the sides of pipes of 300mm bore after they are laid and tested complete all as specified and as directed. |
| 8 | Dismantling of reinforced concrete drain pipes 600mm bore internal dia jointed in cement mortar and taking out of trenches complete all as specified and as directed by the Engineer-in-Charge |
| 9 | Supply and laying 600 mm bore reinforced concrete pipe of Class NP-2, with collars, laid and jointed complete all as specified and as directed by the Engineer-in-Charge. |
| 10 | Taking down cement plaster of any description on brick or stone walls from any height including racking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed. |
| 11 | Material and labour for 15 mm thick rendering in cement mortar (1:6), finished even and smooth without using extra cement to fair face of brick wall / concrete wall surface, |
| 12 | Excavating over areas for each additional 1.5 m or part thereof in depth beyond the first 1.5 metre deep and getting out in any type of soil complete all as specified. |
| 13 | Excavation in trenches not exc 1.50m wide and n exc 1.5m in depth for foundation for cesspits, manholes, sewage line etc and getting out in hard/dense soil as directed. |
| 14 | Excavation in trenches not exc 1.50m wide and n exc 3.0m in depth for foundation for cesspits, manholes, sewage line etc and getting out in hard/dense soil as directed. |
| 15 | Returning filling in soil including spreading leveling watering and well ramming in layers n.exc 25 cm all as specified . |
| 16 | Removing excavated soil to a distance n. exc 50m and depositing were directed at level n. exc 1.5m above the starting point all as specified. |
| 17 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick (below or above ground level) and removing demolishe concrete at lowlaying area and leveling all as directed and as specified by the Engineer-in-Charge. |
| 18 | Plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete |
| 19 | M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in surface channel of drain complete allas specified and directed |
| 20 | M&L for cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping etc, incl necessary formwork complete all as specified |
| 21 | M&L for PCC 1:4:8, Type D2, using 40mm graded stone aggregate, concrete surface furnished fair and rough as in subbase complete all as specified. |
| 22 | Dismantling of Stone slabs, concrete tiles , laid dry , bedded and pointing in any mortar and tiles of any description or thickness in floors, aprons etc complete all as directed. |
| 23 | M&L for Chequered cement concrete tiles 30cm x30cm x 25mm thick, set, jointed and pointed in near cement slurry in floors With grey cement and pigments and including 15mm screed bed in CM 1:4. |
| 24 | M&L for machine pressed precast concrete inter locking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade, glossy finished of approved colour laid over fine sand cushion to a line and slope etc and joined complete including spreading screened river sand over surface for filling the joints etc complete all as specified .(Note- Sand coushening shall be paied seperaty) |
| 25 | M&L for Machine pressed precast coloured concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M30 , glossy finish of approved colour laid over sand coushening to a line and slope including spreading sand over surface to filling the joints etc complete all as specified and directed..(Note- Sand coushening shall be paied seperaty) |
| 26 | M&L for Sand filling under floors or in foundations including watering and consolidation all as specified and directed. |
| 27 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided fo and removind debris at low layind area as directed complete , all as specified and as directed by the Engineer-in-Charge. |
| 28 | M&L for RCC nominal mix, Type B1 1:1.5:3 (20 mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs slab, landings, blaconies, canopies, deck slabs andd in shelves and complete all as specified and as directed. NOTE : Reinforcement will be measured and paid for separately under relevant Item(s). |
| 29 | M&L for Pre-cast RCC 1:1.5:3 type B1 (using 20mm graded stone aggregate) as in cover slab of manholes, septic tanks, sockage well etc. and set in cement mortar 1:4 including dismantling of damaged RCC covers slab complete all as specified and as directed. NOTE : Reinforcement will be measured and paid for separately under relevant Items. |
| 30 | M&L Formwork to soffits of suspended slabs as fair finished surface concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work vertical or to batter with rough finished surfaces of concrete. |
| 31 | M&L for TMT Bars,10 mm dia and above , cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. |
| 32 | M&L for TMT Bars,8 mm dia, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. |
| 33 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 34 | M&L for brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius built in CM 1:6 all as specified and directed . |
| 35 | All as per item Nos 33 above here in before but except bricks. |
| 36 | M&L for walling of random rubble, uncoursed, well bonded, and solidly hearted, built in cement mortar 1:4, complete all as specified and directed |
| 37 | All as per srl item 35 here-in-before but except stones |
| 38 | M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4,and finished surfaces even and Smooth without using extra cement with using water proofing compound all as specified and as directed.(Note :- Supply only WPC shall paid separately) |
| 39 | Supply only Water Proofing Compound. |
| 40 | S&F in repairs PVC (SWR) floor trap, 75 mm dia plain with grating including jointing with solvent cement. Complete all as specified and directed. |
| 41 | S&F in repairs Cast iron Nahani trap suitable for outlet of dia of 75mm with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all specified and directed. |
| 42 | S&F PVC (SWR) Soil, Waste and Ventilating Pipe 110mm bore (dia), single socketed, in any length with Rubber Ring Joints fixed to Walls, as in repair complete all as specified and as directed. |
| 43 | S&F PVC (SWR) Bend 110mm bore (dia), any type, equal or unequal with Access Door, etc. and Jointing with Solvent Cement, complete all as specified and as directed. |
| 44 | S&F PVC (SWR) 75mm bore, pipes single socketed in any length with rubber ring joints fixed to walls. |
| 45 | S&F PVC (SWR) 75 mm bore, bends any type, any radius with access door and jointing with solvent cement, complete all as specified and as directed. |
| 46 | S&F PVC (SWR) branch piece, single (single Y) equal or unequal access door for 75 mm bore pipe all as specified and as directed. |
| 47 | Supply and fixing in repair cast iron (grade FG 150) manhole cover / grating / gully trap etc including frame (weighing exceeding 5 Kg each) of different sizes, fixed in concrete cover with PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as directed by the Engr-in-Charge. |
| 48 | Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate), finished smooth and reforming benching for 150mm bore pipe as required and as directed by the Engineer-in-Charge. |
| 49 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises all as specified and directed. |
| 50 | M&L for virified tiles ( double charged ) light shade 9mm mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. Note: Shade and design/pattern of tiles shall be as directed by GE. |
| 51 | M&L for coloured vitrified tiles ( double charged )of same shade and design as abobe iten No as in skirting 9 mmthick (square/ rectangular) polished, set and jointed in neat cement slurry and pointed in coloured cement to match shade of tile over and including 10mm thick backing coat in CM 1:3 complete all as specified and as directed. |
| 52 | M&L for nonskid joint free ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.18 Sqm but n. exc 0.38 Sqm, of approved colour any print/design in floor etc set and jointed in neat cement slurry and pointed in white/coloured cement to match the surfaces, over and including screed bed 15mm thick in cement mortar 1:6. |
| 53 | M&L for glazed ceramic joint free tiles in vertical surfaces 450x300x7mm thick of approved colour any print/ design set and jointed in neat cement slurry and pointed in white/coloured cement to match the surfaces, all as specified and directed. |
| 54 | M&L for 10 mm thick screed bed in cement mortar 1:4 on vertical suraces of wall as base to glazed tiles complete all as specified and directed. |
| 55 | M&L for preparation of old cement concrete chequered/ interlocking path tiles and applying two coats of indigo floor paint any dark shade to the entire satisfaction of Engr -in- Charge complete all as specified and directed. |
| 56 | Cleaning of manhole of any depth and size by opening cover and taking out accumulated brick bats, garbage, silts or any other Items, removing and carrying same to a distance exc. 50m but not exc. 100 M and buried under ground (minimum 300mm below ground level) including excavation of pits and returning, filling in and removing of surplus soil, dressing ground to slope if required, re-fixing the cover after cleaning of manhole, complete all as specified and as directed. |
| 57 | Cleaning gully trap any depth by opening cover and taking out accumulated night soil, sludges, brick bats or any other Items, removing and carrying same to a distance exc. 50m and not exc. 100m and buried under ground (minimum 300mm below ground level), re-fixing the cover after cleaning of gully traps including excavation of pits and returning, filling in and dressing of surplus soil, ground to slope if required, complete all as specified and as directed. |
| 58 | Cleaning of blocked water closet (of any type / pattern) including connected CI pipe line (of any bore) upto 1st manhole as directed by the Engineer-in-Charge. |
| 59 | Cleaning nahani trap any depth by opening cover and taking out accumulated night soil, sludges, brick bats or any other Items, removing and carrying same to a distance exc. 50m and not exc. 100m and buried under ground re-fixing the cover after cleaning of nahani traps complete all as specified and as directed. |
| 60 | Mechanically pumping out sewage water from Septic Tanks / Soak Wells / Sumps etc., of any size / dia by means of mechanical operated equipment / trolley mounted Browsers with taking all precautionary measures and removing water to outside MD land (working on foul condition) complete all as directed.(Note:-Minimum 01 No of safaiwala to be provided to attened day to day complaint on all working day for sl item no - 48 to 52). |
| 61 | Maintaining of cleaning of spout on roof slabs,chajjas , rainwater pipes , shrubs , green plantation etc. from any position of the buildings and including make good to damaged portion in any description with out any extra cost, complete all as specified and directed by Engr -in- charge . ( Note :- Plan area of the roof and portico shall be measured for payment, cleaning of chhajja shall be included in the rate of roof area) |
| 62 | Cleaning of sewage line of any dia either manually (by pushing a piece of bamboo split, tied with gunny bags at one end from one manhole to another manhole) or by mechanically operated pump including dewatering, desilting and well flushing the line with water and testing on completion complete as directed by the Engineer-in-Charge. |
| 63 | Cleaning of blocked waste line (of any bore) from sink / urinal / wash- hand basin to floor trap manually (by pushing a piece of bamboo split, tied with gunny bags at one end to other) including dewatering and well flushing the line with water and testing on completion complete as directed by the Engineer-in-Charge. |
| 64 | S&F in repairs vitreous china squatting pan ‘ORISSA’ pattern of size 580X440mm white with P or S Trap, integral foot rest indian rubber cones (Nozzle of WC Pan) joints between flush pipe and socket of WC pan (excluding flushing cistern and flush pipe), fixing with and including provision of 150 mm thick lime concrete bedding including taking down unserviceable WC pan and connected items of any description, complete all as specified and as directed. |
| 65 | S&F in repairs first quality vitreous China wash down water closet pan (pedestal pattern), white, of size not less than 400mm x 400mm x 340mm (excluding fixing bolts, flushing cistern and flush pipe) but including provision of plastic water closet seat, white , closed pattern with flat bottom, and cover and mild steel chromium plated hinging device complete all as specified and directed. |
| 66 | S&F in repairs Flushing cistern,PVC valveless, syphonic action type 10 litre capacity,low level, white, with inlet,ball valve, float and handle and brackets and 32mm dia PVC flush pipe complete all as specified. |
| 67 | M&L for PVC Bio Septic tank 2000 Ltr capacity having appr size 2050 mmx1200mm x1220mm , having intigrated PVC lid height laid in excavated pit and provide inlet and outlet connection to drain. Complete all as specified and directed.Make :- Sintex / plasto |
| 68 | S&F in repairs vitreous china wash basin , white flat back size 550x440mm excluding chain and plug and porcelain stopper but including brackets all as specified & directed including 32mm bore CP based fittings and PVC waste pipe suitable for 32mm bore complete |
| 69 | S&F in repairs, 32mm dia PVC flexible waste pipe with fittings of suitable length as per site requirement for WHB/Sink or Urinal complete all as specified and directed. |
| 70 | S&F in repairs, PVC connection 15mm dia and 60 cm long with 2 Nos PTMT nuts complete all as specified and directed. |
| 71 | S&F in repair fancy type CP bib taps cast copper alloy chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete. |
| 72 | S&F in repair Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore, fixed in repairs complete. |
| 73 | S&F in repairs, 15mm bore Stop valve, cast copper alloy, chromium plated fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron/GI pipe or for union complete all as specified and directed. |
| 74 | S&F in repairs, stainless steel grating round of size 125mm complete all as specified and directed. |
| 75 | S&F in repairs ABS Health Faucet Set with SS Hose & ABS Wall Bracket in Chrome Finish incl chrome flexible pipe of 1.00m length and fixing brackets and fixed as per manufacturers instruction. Complete all as specified and directed.Cat No BEA-81 of Prayag or equvalent |
| 76 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion of concrete, brick masonary and making good disturbed ground all as specified and directed. |
| 77 | Excavating in post holes (or similar holes)in hard/dense soil, each n exc 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 78 | Dismantling of fencing wire mesh of any type complete all as specified and as directed. |
| 79 | Supply only PVC coated tuflon chain link fencing (2.5mm wire+1.5mm PVC coating) of approved mesh of size 75mm size and nominal dia GI wire with tolerance as per IS to any type of standards , rails straining bolts etc., including provision of line wires , binding wire etc.,complete all as directed. |
| 80 | Supply only Chain link MS galvanised fencing, any size or type complete all as directed. |
| 81 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire all as specified and directed |
| 82 | S&F mild steel work as in posts and struts in fencing including cutting top to shape as direct, drilling holes, notching for wire etc,. flat iron fillets (for securing wire mesh etc.) incl all necessary drilling, bolting or reveting,etc and similar work conforming to Fe-290 (Gde E165) all as specified and directed. |
| 83 | S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 (Gde E165) all as specified and directed. |
| 84 | Mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5 Cm long but not exceeding 10 cm long , 5 to 10mm dia of neck as specified and directed. |
| 85 | S&F in repairs Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specifed and directed. (each line wire to be measured) |
| 86 | M & L welding in repairs exceeding 2.5 cm but not exceeding 5 cm in length with thickness of metal not exceeding 6mm complete all as specified and as directed.Note: (1) Works shall be carried out in multi storey Building upto 2nd floor. |
| 87 | Dismantling plain or corrugated steel sheeting, any gauge or thickness incl Nainital or similar pattern roof coverings all as specified and directed. |
| 88 | S&F in repairs, floor mounted bowl (water closet) with cistern for coupled WC with UF soft close slim seat cover, hinges, dual flush cistern fitting and fixing accessories size 380 x 655 x 765mm S trap 250m, white including connecting to trap etc., complete fixing all as specified and directed.Make: Jaquar Cat No LYS-WHT-38751S250UFSMZ |
| 89 | S&F in repairs, vitreous china Urinal, half stall type with sensor, white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing grating and union for discharge pipe etc., complete all as specified and directed. Make : Jaquar CAT No CAN-1151N or techno commercially equavalent in Hindware or Parryware |
| 90 | S&F in repair brass chromium plated auto closing push cock for urinal 15mm bore , screwed for iron pipe and fixed complete all as specified and directed.Make : Jaquar CAT No PSR 073 or techno commercially equavalent in Hindware or Parryware |
| 91 | S&F in repairs, vitreous china Urinal, half stall type white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing grating and union for discharge pipe etc., complete all as specified and directed.Make : Jaquar CAT No CAN-1151N or techno commercially equavalent in Hindware or Parryware |
| 92 | Dismnantling of wrought iron or mild steel works of any description not otherwise provided for complete all as directed. |
| 93 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, fixed with self tapping screws as specified. |
| 94 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, valley gutter, ridge and fixed with crumple joint etc fixed with self tapping screws all as specified and directed. |
| 95 | S&F mild steel work grade Fe-290 grade E-165 as in posts ,roof trusses (framed/ unframed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, hollow pipes or flat sections) including distance pieces, cleats etccomplete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |