| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair /Maint to high mast/semi high mast lights, poles, junction boxes with allied works at Int, MI Room, Signal Center and other locations under GE (Utilities) Udhampur Contract No: GE/U-29/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Taking down old/US gate light and garden light of any capacity from HQNC, CP colony, comd camp and making good complete all as specified and directed by Engineer-in-Charge. |
| 3 | Taking down old/US cable up to 25 Sqmm from HQNC, CP colony, comd camp and making good complete all as specified and directed by Engineer-in-Charge. |
| 4 | S&F energy efficient post top light fitting on wall/gate 360 degree indirect light with IP 65 protection high quality integrated LEDs assuring soothing warm white light all night long LED 45 W black case aluminium including all necessary wiring LED bulb , clamps, nut and bolts mounting accessories etc and providing complete all as specified and directed by Engineer-in-Charge. Make :- Havells Cat Part Number RUBYPT45WLED757PSYMTOPC or equivalent make mentioned in PS.Note :- The Contractor provide suitable GI pipe up to 30CM grouting on post top with PCC for fixing of post top lights. The Cost is deemed to be included in the quoted rate of the items. |
| 5 | S&F energy efficient post top light fitting on wall/gate 360 degree indirect light with IP 65 protection high quality integrated LEDs assuring soothing warm white light all night long LED 25 W black case aluminium including all necessary wiring LED bulb , clamps, nut and bolts mounting accessories etc and providing connection complete all as specified and directed by Engineer-in-ChargeMake :- Havells Cat number RUBYPT25WLED757SSYMTOPC or equivalent make mentioned in PS.Note :- The Contractor provide suitable GI pipe up to 30CM grouting on post top with PCC for fixing of post top lights. The Cost is deemed to be included in the quoted rate of the items. |
| 6 | S&F energy efficient post light (bollard light) 360 degree light distribution with IP-65 ,85.5 cm height and 17.4 cm width fitting on ground , wall etc including excavation and PCC 300cmx300cm and high quality integrated LEDs assure soothing warm white light all night long LED 10 W black case aluminium , synthetic model Robin including all necessary wiring LED bulb , clamps, nut and bolts mounting accessories etc all as specified and directed by Engr-in-Charge. Make Havells cat part CONENXGBLS8WLEDPSYM857TOPCM or equivalent make mentioned in PS.Note :- The Contractor provide PCC foundation for fixing of bollard lights. The Cost is deemed to be included in the quoted rate of the items. |
| 7 | Supply and fix LED spike light fitting 9/10 watts(Multi colour), IP65, Energy Saving LED light with PDC , Aluminium body & secondary Optical lens for superior light distribution , Efficacy > 55 Lm/W. 5700k ,complete all as specified and directed by Engineer-in-Charge. Make Havells Cat part No-LYCUSSPS9WLED73OPSYMBOTG or equivalent make in PS.Note :- The Contractor provide PCC foundation for fixing of bollard lights. The Cost is deemed to be included in the quoted rate of the items. |
| 8 | S&F smart bright Flood light fitting LED type, 80 Watts 240 Volts luminous efficiency not less than 100 lm/Watt , with toughened glass visor, PDC housing with IP 65 flood light sleek and robust design for better aesthetics, reliable and sturdy, mounted on wall and providing connection complete all as specified and directed by Engr-in-Charge. Make - Havells Cat Part No-JEAALBAFLOODLIGHT80W or equivalent make in PS. Note :- Colour of lights shall approved by Engr-in-Charge. |
| 9 | S&F smart bright Flood light fitting LED type,50 Watts 240 Volts luminous efficiency not less than 100 lm/Watt ,with toughened glass visor, PDC housing with IP 65 flood light sleek and robust design for better aesthetics , reliable and sturdy, mounted on wall and providing connection complete all as specified and directed by Engineer-in-Charge.Make - Havells Cat Part No-JATAQUANTOPLUSFLP50WLED757SYMLENS or equivalent make in PS. Note :- Colour of lights shall approved by Engr-in-Charge. |
| 10 | Supply and fix in replacement of LED flood light, 120 watt, 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, CT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engineer-in-Charge.Make - Havells Cat Part No-JETAIRSFL120WLED757APWBLTG or equivalent make in PS. |
| 11 | Supply and fix LED flood light, 150 watt, 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, CT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engineer-in-Charge.Make - Havells Cat Part No-JETAIRSFLS150WLED757P2AV2PWBLTG or equivalent make in PS. |
| 12 | Supply and fix LED flood light, 250 watt, 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, CT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engineer-in-Charge.Make - Havells Cat Part No-JETAIRISMAXFL250WLED757PWBLTG or equivalent make in PS. |
| 13 | Supply and fix LED street light fitting 90 Watt, 230 V, AC outdoor type with high pressure die cast aluminium hosing and heat resistant (in repair) complete with driver, with toughened glass vison, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engineer-in-Charge.Make - Havells Cat No-ENDURASUNDOWNSL90WLED765PASYBOTG or equivalent make in PS.Note :- Contractor provide suitable MS reducer with clamp for fixing of street light fitting with existing street light bracket. The cost of the same is deemed to be included in relevant street light items. |
| 14 | Supply and fix LED street light fitting 60 Watt , 230 V, with toughened glass visor,AC outdoor type with high pressure die cast aluminium hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge. Make - Havells Cat No-ENDURASUNDOWNSL60WLED765PASYBOTG Note :- Contractor provide suitable MS reducer with clamp for fixing of street light fitting with existing street light bracket. The cost of the same is deemed to be included in relevant street light items. |
| 15 | Supply and fix inreplacement of LED Tiranga Rop light 18 Mtr,IP 65,Input Power 10W/meter,Input Voltage 220-240 VAC Input frequency 50 Hzs,Input current 0.045 Amp/Mtr,Power factor 0.95,Width of strip(+/- 0.1 mm) 8 mm length/reel-18 mtrs,No of led per mtr 120 LED,LED Beam angle 120 degree ,Rope light per Colours length 6 mtr orange, 6 mtr white ,6 mtr Green,Fixing method silicone clip ,Ingrass Protection -IP -65, Ingrass protection method silicone tube ,silicone tube dimention 11.5x5.5 mm+/- 0.5 mm,working temp range-20 degree celcius to + 45 degree celcious ,working humidity range 10-90 RH and complete all as specified and directed by Engineer-in-Charge. Make -Wipro/Philips/Oreint. |
| 16 | Supply and fix inreplacement of Terminal box made out of SMC with hinged door and locking arrangements of size 260x260x150mm (in repair) including Backlite 4 way connector,M.S. Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer ,electrical connections including MCB SP 6-32 Amps, complete all as specified and directed by Engineer-in-Charge.Make - Sintex product or equivalent in Havells/CG/Pplycab/Bajaj. |
| 17 | M&L for Sub main wiring complete with 2x1.5 sqmm, single core, multi stranded copper conductor FRLS-H PVC insulated and sheathed cable 1100 Volts grade, drawn in PVC Conduit in surface /PVC conduit on surface (as required) along Poles/ walls roofs etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly, complete all as specified and directed by Engineer-in-Charge at site. Note :-(i) All three wire/cable(phase, neutral and earth) should be run through for each individual circuit from the DBs. (ii) Two run / four runs of cable and one run / two runs of earth conductor and PVC Conduit be measured as one length. |
| 18 | Supply and fix inreplacement of MCB TPN 40-63 Amp, 230V, 50Hz, 10 KA complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply and fix inreplacement of MCB TP 40-63 Amp, 230V, 50Hz, 10 KA complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply and fix inreplacement of MCB DP 40-63 Amp, 230V, 50Hz, 10 KA, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply and fix inreplacement of MCB SP 40-63 Amp, 230V, 50Hz, 10 KA, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Supply and fix inreplacement of MCB SP 6-25 Amp, 230V, 50Hz, 10 KA, complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply and fix inreplacement of Lamp holder (in replacement) PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply and fix inreplacement of LED lamp warm white/white 9 Watt (in replacement) complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply and fix inreplacement of LED lamp warm white 18 Watt (in replacement) complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and fix in replacement of PVC insulated multi stranded aluminium conductor PVC cable sheathed 10 Sqmm twin core (in replacement) and making connections of street light fittings with overhead lines/UG Cable complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and fix in replacement of PVC insulated multi stranded aluminium conductor PVC cable sheathed 6 Sqmm twin core (in replacement) and making connections of street light fittings with overhead lines/UG Cable complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply and fix in replacement of Two single core PVC insulated and sheathed copper conductor cable (in repair) 2.5 Sqmm nominal size and one single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size for earth continuity from main lines to the street light fittings after removing u/s one complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply and laying LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor stranded of size 6 Sqmm 2 core complete all as specified and directed by Engineer-in-Charge. |
| 30 | Description all as per Ser item No 28.00 here-in-before, but size of 10 Sqmm 2 core |
| 31 | Description all as per Ser item No 28.00 here-in-before, but size of 10 Sqmm 4 core |
| 32 | Description all as per Ser item No 28.00 here-in-before, but size of 16 Sqmm 4 core |
| 33 | Description all as per Ser item No 28.00 here-in-before, but size of 25 Sqmm 3.5 core |
| 34 | Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 63 mm and inner dia 50 mm polyethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and directed by Engineer-in-Charge. |
| 35 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge. |
| 36 | Excavation in trenches not exc. 1.5 mtr in wide and exc. beyond1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge. |
| 37 | Returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge. |
| 38 | Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and erect in position steel tubular swaged poles complete with cast iron base plate ,finial taper plug,bolts,nuts & screws as specified type 410 SP-31(9.00 metres long) complete all as specified and directed by Engineer-in-Charge. |
| 40 | M & L plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate for foundation of poles complete all as specified and directed by Engineer-in-Charge. |
| 41 | M & L plain cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate for poles complete all as specified and directed by Engineer-in-Charge. |
| 42 | Earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 CM thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth strip 32X6 mm size up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick and PCC chamber pit with PCC 1:3:6 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 all as specified and directed.Note :- Contractor Shall provide earth pit chamber board of 3.15mm thick mild steel sheet of size 45cmX30cm fixed with12mm thick MS rod two nos up to 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters 6cm height i.e Eart pit No, Location, Earthing test Value and date complete all as specified and directed by Engineer-in-Charge. |
| 43 | S & F GI earth continuity conductor or main earthing lead of size 32X6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for earthing etc. as required complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supplying and laying in replacement of GI tubing light grade 40mm bore for protection of strip fixing to pole/wall or in such similar position complete all as specified and directed by Engineer-in-Charge. |
| 45 | M&L for providing cement concrete Type B1 1:2:4 (using 20mm graded stone aggregate ) as in hard standing after laying cable under road etc complete all as specified and directed by Engineer-in-Charge. |
| 46 | M&L for cutting of road for passing Cables under road along with GI pipes complete all as specified and directed by Engineer-in-Charge. |
| 47 | Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings MCCBs are to busbar spadles to fitted complete base frame of 50x50x6mm angle iron, powder coated, having front and rear openable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- |
| 48 | Incoming:-(i) MCB 63 Amps 4 Pole 10 KA-01 No.(ii) 3 HP, 415V, 3-phase DOL motor starter(iii) Automatic street light control switch of 18-21 KW three phase(40 Amp per phase) having protection IP-66 using Infrared sensor based Nature Switch for automatic switching of street light. Nature switch operation should be based on Natural Light Lux*level. Reqd illuminance level also have part night operation facility for min 4 hrs to max 12 hrs. The sensor along with suitable rating power contractor (s), termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection. The circuit should be also have provision for manual operation (i.e. sensor by pass option) complete all as specified and directed. Make - Navdeep with smart timer Model no -Navdeep-66-18kw3P/Lauritz Knudsen/ Legrand.Outgoing :- MCB 63 Amps 4 pole 10 KA-03 NosNote – (i) 02 Nos (one on each door panel ) with minimum four number combination lock has has to be fixed in the panel. The rate of the padlocks are included in the quoted rate of the panel. |
| 49 | S&F in replacement GI bracket for fixing street/ security light fitting made out of GI pipe medium grade 25/40 mm dia upto 1.50 Mtr long bent to required angle/ shape complete with MS flat iron clamp of size 50x5 mm complete with nut, bolt, washer of suitable size as per requirement of site as directed etc and fixed in pole/wall including two coats of aiuminium paint over a coat of red oxide primer to MS clamps , nut ,bolts etc complete all as specified and directed by Engineer-in-Charge. |
| 50 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including dismantling existing rusted sections complete all as specified and directed by Engineer-in-Charge. |
| 51 | Material and labour for Painting to RCC /steel tubular poles 9/12 metre long at surface of any description over 10 CM grith or width ,not otherwise described,prepare old or new untreated surface,old painted surfaces including priming cement based paints plaster with synthetic enambled paint coat and plastic emulsion coat over surface with two coats of aluminium paint including brackets, clamps, nuts bolts, washer etc. including making yellow and black strips alternatively (30 cm width each) on pole upto 1.5 metre from the ground level and marking of pole Nunber as with black paint having back ground yellow as per existing complete all as specified and directed by Engineer-in-Charge. |
| 52 | Supply and fix in repacement of Terminal box made out of SMC with hinged door and locking arrangements of size 140x140x95mm (in repair) including Backlite 4 way connector,M.S. Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer ,electrical connections complete all as specified and directed by Engineer-in-Charge. |
| 53 | Supply, Install, Test and Commissioning of wall mounted LT feeder pillar box indoor type fabricated out of 3.15 mm thick CRCA sheet double door, CPRI approved of size not less than 600X600X300 mm complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd. with the followingcomplete all as specified and directed by Engineer-in-Charge:-Incoming:- (a) S&F MCCB FP 125 Amps 35 KA - 01 No.Outgoing :- (a) MCB 40/63 Amps 10 KA- 05 Nos (b) S & F aluminium bus bar 600 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(c) Voltmeter 0-500V with selector switch (Digital type)-01 No(d) Ammeter 0-50 Amps with CTs (50/5Amps) and selector switch(Digital type)-01 No(e) Indicating lamps (RYB) -01 Set. (f) PCC Foundation (Civil works) for grouting of panel |
| 54 | Supply, install in replacement of 150 amp copper Bus bar with enclouser wall mounted size 300 mmX250 mm ,suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 2 mm CRCA MS sheet for cable entry and locking arrangement, complete all as specified and directed by Engineer-in-Charge. |
| 55 | Supply and fix in replacement of of double drum winch (manual/motorized) suitable for 12/15/18 mtr high mast including self-sustaining braking system complete all as specified and directed by Engineer-in-Charge.Make -Bhagirath Heavy Transmission (BHT India)/Buildtech Engineering/Powertek Equipment Company |
| 56 | Supply and fix inrepacement of Steel wire rope (galvanized), 8/6 mm dia, multi-strand two run from gear box to top chain pully complete as per the existing size of high mast lights up to 18 mtr height pole complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply and fix in replacement of heavy duty pulley blocks of MS/CI with ball bearing suitable for smooth operation as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply and fix in replacement of lantern carriage assembly GI ring suitable for mounting 4–8 flood lights complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply and fix in replacement of guide frame / head frame assembly suitable for 12/15/18 Mtr height pole as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fix in replacement of stainless steel fasteners, shackles, hooks, thimbles, clamps etc as directed at site complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply and fix in replacement of suspension system (3-point / 4-point suspension arrangement) suitable for 12/15/18 Mtr height pole complete all as specified and directed by Engineer-in-Charge. |
| 62 | Supply and fix inrepacement of limit switch/ safety locking arrangement for carriage of heighmast light pole suitable for 12/15/18 Mtr hight complete as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 63 | Material and labour for Supply, installation, testing & commissioning in replacement of gear assembly suitable for 3 HP motor for highmast light complete all as specified and directed by Engineer-in-Charge. |
| 64 | Material and labour for supply, installation, testing & commissioning in replacement of three phase 3 HP motor suitable for 12/15/18 Mtr height highmast light as per the existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 65 | Material and labour for spray Painting to 10/12/15/18 long heighh mast light pole at surface of any description over 10 CM grith or width ,not otherwise described,prepare old or new untreated surface,old painted surfaces including priming cement based paints plaster with synthetic enambled paint coat and plastic emulsion coat over surface with two coats of aluminium paint including brackets, clamps, nuts bolts, washer etc. including making yellow and black strips alternatively (30 cm width each) on pole upto 1.5 metre from the ground level and marking of pole Nunber as with black paint having back ground yellow as per existing complete all as specified and directed by Engineer-in-Charge. |
| 66 | Supply and fix LED Flaxi strip Neon AC LED warm white Colour Strip Light 50 mtr ,IP 65 input voltage 220-240 VAC input frequency 50 Hzs power factor ss protection -IP -65 working temp range -20 degree celcius to + 45 degree celcius working humidity range 10-90 RH complete all as specified and directed by Engineer-in-Charge.Make-Bajaj/Philips / Crompton/Havells:- FLAXISTRIPNEON50MIP65AC7.5W/830V1 |
| 67 | Supply and fix LED strings lights 10 mtr (Multi colour) ,21D IP 44 input voltage 220-240 VAC input frequency 50 Hzs input current 0.045 Amp/Mtr.Power factor ss protection -IP -44 working temp range -20 degree celcius to + 45 degree celcius working humidity range 10-90 RH complete all as specified and directed by Engineer-in-Charge.Make-Bajaj/Philips / Crompton/Havells:- Joy LED String 10 M 21D IP44 LHEHCIP5UB4K010 |
| 68 | Material and labour for Routine periodical maintenance/servicing of heighmast light assembly of 10/12/14 Mtr height complete including all consumables items like cotton, waste cloth, kerosene oil,oil, Grease etc complete all as specified and directed by Engineer-in-Charge and comprising of the following :-(a) Checking, cleaning and lubrication of double drum winch machine (manual/motorized) (b) Inspection of SS wire rope (3/5 mm) including greasing and checking for wear/tear.(c) Checking of pulley system, guide rollers and safety locks.(d)Tightening of foundation bolts and mast segments.(e)Checking of lantern carriage alignment and balancing. (f)Checking and tightening of all electrical connections in feeder pillar/control panel.(g)Testing of contactors, timers, MCB/MCCB, and relays.(h)Insulation resistance (IR) testing of cables.(j)Checking earthing system (earth resistance measurement). |
| 69 | (k)Replacement of damaged lugs, thimbles, glands (if required) (l)Cleaning of LED flood light fittings (external/internal).(m)Checking driver, wiring and connectors of LED fittings.(n)Replacement of faulty LED drivers / fittings (if required).(o)Focusing and alignment of flood lights. (p)Lowering of lantern carriage for maintenance.(q)Raising and proper locking after maintenance.(r)Touch-up painting of mast (damaged portion) with approved paint.(s)Anti-corrosion treatment of bolts and hardware.(t)Checking aviation obstruction light (if provided).(u)Cleaning of control panel and foundation area.(v)Documentation & submission of maintenance report. |
| 70 | Material and labour for taking out heighmast lights upto 18 Mtr height pole and Shifting of the same from one place to another place at a distance upto 2 KM as directed with mechanical hydra and install the same by providing PCC foundation as per OEM recommendation complete all as specified and directed by Engineer-in-Charge.Note :- (i)The cost of material such as PCC foundation , base plate , nuts , bolts etc for installation of pole is deemed to be included in the quoted rate of the items.(ii) Cost of the transportation is deemed to be included in the quoted rate of the items. |
| 71 | Supply in fix inreplacement of 3 HP, 415V, 3-phase DOL motor starter complete with contactor, thermal overload relay (6–10A), push buttons, indicating lamps, wiring etc suitable for Highmast light Motor complete all as specified and directed by Engineer-in-Charge. |
| 72 | Note for Item No 6.00 to 13 and 30.00, 31.00 & 32.00 :- All LED/Street/Flood lights and Cable shall be embossed from the Company/Contractor by GE (U) Udhampur and CA No Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |