| 1 | M&L for Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 2 | M&L for Point wiring with 1.5 Sqmm (nominal area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC casing and capping not less than 20mm size, medium grade with all necessary fittings along with continuous earth wire 1.5 Sqmm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including MS pressed steel terminal boxes with phenolic laminated sheet /or on PVC reactangular box of suitable size for One light point or one fan point or Call Bell point controlled by one switch etc. complete all as specified and as directed. |
| 3 | All as per item No 2 above but for One light point controlled by Two Nos of 2 Way switches etc. complete all as specified and as directed. |
| 4 | All as per item No 2 above but for One 3/5 -pin switch socket outlet 5/6 amps on independent board etc. complete all as specified and as directed. |
| 5 | All as per item No 2 above but One 3 pin socket outlet 5/6 Amps on the same board with other switchs etc. complete all as specified and as directed. |
| 6 | M&L for Point wiring with 2.5 Sqmm (nominal area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC casing and capping not less than 20mm size, medium grade with all necessary fittings along with continuous earth wire 2.5 Sqmm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly,with and including MS pressed steel terminal boxes with phenolic laminated sheet /or on PVC reactangular box of suitable size complete for 15 Amps on independent board etc. complete all as specified and as directed. |
| 7 | M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (heavygrade) andconduit accessories along with continuous earth wire 1.5 Sqmm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly,with and including MS pressed steel terminal boxes with phenolic laminated sheet /or on PVC reactangular box of suitable size complete for One light point or one fan point, Call Bell point controlled by one switch etc. complete all as specified and as directed. |
| 8 | All as per item No 7 above but for one 3/5 pin switch socket outlet 5/6 Amps on independent board etc. complete all as specified and as directed. |
| 9 | M&L for Point wiring with 2.5 Sqmm (nominal area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit (heavygrade) andconduit accessories along with continuous earth wire 2.5 Sqmm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly,with and including MS pressed steel terminal boxes with phenolic laminated sheet /or on PVC reactangular box of suitable size complete for 15 Amps on independent board etc. complete all as specified and as directed. |
| 10 | S&f switch piano flush type button, single pole, 5/6 Amps, one way etc. complete all as specified and as directed. |
| 11 | S&F switch piano flush type button, single pole, 5/6 Amps, two way etc. complete all as specified and as directed. |
| 12 | S&F Bell, AC 230 Volts single pole including mounting block etc. complete all as specified and as directed. |
| 13 | S&F Bell push flush type, 5 Amps button etc. complete all as specified and as directed. |
| 14 | S&F ceiling rose surface bakelite 65 X 50 mm three terminal etc. complete all as specified and as directed. |
| 15 | S&F switch socket combination 2-in-1, 3 Pin, 5 Amps flush type etc. complete all as specified and as directed. |
| 16 | S&F switch socket combination 2-in-1, 5 Pin , 6/16 Amps flush type universal etc. complete all as specified and as directed. |
| 17 | S&F LED batten surface / wall mounted with extruded polycarbonate housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 20W, system efficiency of ≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 25,000 burning hrs (min) with operating range of 150-270 V AC, etc. complete all as specified and as directed by Engr-in-charge. |
| 18 | S&F LED batten surface / wall mounted with extruded polycarbonate housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 10W, system efficiency of ≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 25,000 burning hrs (min) with operating range of 150-270 V AC, etc. complete all as specified and as directed by Engr-in-charge. |
| 19 | S&F wall light fitting made up of polycarbonate suitable with 9W LED lamp B22 base, complete including LED lamp etc. complete all as specified and as directed by Engr-in-charge. |
| 20 | S&F LED bulkhead light of 10W with system efficiency of ≥90 lumens/W, Ingress protection IP 66, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per L7O criteria with range 150-270V AC all as per specified and directed.pressure die-cast housing along with polycarbonate diffuser and LED's IP-65 protction of watt,PF>0.95, etc. complete all as specified and as directed. |
| 21 | M&L for lamp/angle holder of insulated body with back plate for batten fitting etc. complete all as specified and as directed. |
| 22 | S&F LED retro fit lamp B-22 holder base with poly carbonate body and aluminium heat shrink of 10W etc. complete all as specified and as directed by Engr-in-charge. |
| 23 | S&F in repairs switch piano flush button, single pole, 5/6 Amps, one way etc. complete all as specified and as directed. |
| 24 | S&F in repairs switch piano flush button, single pole, 5/6 Amps, two way etc. complete all as specified and as directed. |
| 25 | S&F in repairs Bell, AC 230 Volts single pole including mounting block etc. complete all as specified and as directed. |
| 26 | S&F in repairs Bell push flush type, 5 Amps button etc. complete all as specified and as directed. |
| 27 | S&F in repairs ceiling rose surface bakelite 65 X 50 mm three terminal etc. complete all as specified and as directed. |
| 28 | S&F in repairs switch socket combination 2-in-1, 3 Pin, 5 Amps flush type etc. complete all as specified and as directed. |
| 29 | S&F in repairs switch socket combination 2-in-1, 5 Pin , 5 /16 Amps flush type universal etc. complete all as specified and as directed. |
| 30 | S&F in repairs modular switch flush button ac 230 V single pole 6 Amps one way etc. complete all as specified and as directed. |
| 31 | S&F in repairs modular switch flush button ac 230 V single pole 16 Amps one way etc. complete all as specified and as directed. |
| 32 | S&F in repairs modular socket 6 Amps 5 pin etc. complete all as specified and as directed. |
| 33 | S&F in repairs modular socket 6/16 Amps 3 pin combined etc. complete all as specified and as directed. |
| 34 | S&F in repairs LED batten surface / wall mounted with extruded polycarbonate housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 20W, system efficiency of ≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 25,000 burning hrs (min) with operating range of 150-270 V AC, etc. complete all as specified and as directed by Engr-in-charge. |
| 35 | S&F in repairs LED batten surface / wall mounted with extruded polycarbonate housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption 10W, system efficiency of ≥100 lumens/W, Ingress protection IP 20, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 25,000 burning hrs (min) with operating range of 150-270 V AC, etc. complete all as specified and as directed by Engr-in-charge. |
| 36 | S&F in repairs 6W LED 3000/6500 K Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver etc. complete all as specified and as directed by Engr-in-charge. |
| 37 | S&F in repairs 9W LED 3000/6500 K Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver etc. complete all as specified and as directed by Engr-in-charge. |
| 38 | S&F in repairs 12W LED 3000/6500 K Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver etc. complete all as specified and as directed by Engr-in-charge. |
| 39 | S&F in repairs 15W LED 3000/6500 K Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver etc. complete all as specified and as directed by Engr-in-charge. |
| 40 | S&F in repairs LED 2X2 PANEL 36W 3000/6500 K Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong /Grid ceiling etc. complete all as specified and as directed by Engr-in-charge. |
| 41 | S&F in repairs LED building security light fitting 35W, 230V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including fixing arrangement etc. complete all as specified and as directed. |
| 42 | S&F in repairs lamp/angle holder insulated body with back plate for batten fitting etc. complete all as specified and as directed. |
| 43 | S&F in repairs LED retro fit lamp B-22 holder base with poly carbonate body and aluminium heat shrink of 10W etc. complete all as specified and as directed by Engr-in-charge. |
| 44 | S&F in repairs LED bulkhead light of 10W with system efficiency of ≥90 lumens/W, Ingress protection IP 66, colour rendering index CRI>80, driver efficiency>85%, power factor > 0.90, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per L7O criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60 V DC as per IEC standard all as per specified and directed.pressure die-cast housing along with polycarbonate diffuser and LED's IP-65 protction of watt,PF>0.95 etc. complete all as specified and as directed. |
| 45 | S&F wall light fitting made up of polycarbonate suitable with 9W LED lamp B22 base, complete including LED lamp etc. complete all as specified and as directed by Engr-in-charge. |
| 46 | S&F in repairs LED bed side lamp 3W LED Black 3000K etc. complete all as specified and as directed by Engr-in-charge. |
| 47 | S&F in repairs LED Picture light, 6W etc. complete all as specified and as directed by Engr-in-charge. Make: Cat Part No 30973 of Philips or equivalent in Havells/Crompton etc. complete all as specified and as directed by Engr-in-charge. |
| 48 | S&F in repairs LED flood light, 20W, die cast aluminium housing, high quality light diffuser, robust driver, wide operating voltage 100V-240V, Colour temp- 6500K, Input power - 30 Watt, protection to IP 65, LED Beam Angle: 120° etc. complete all as specified and as directed by Engr-in-charge. |
| 49 | S&F in repairs indoor LED PL-L Base lamp 4 pin, 18W, 6500K, 240 Volts, etc. complete all as specified and as directed by Engr-in-charge. |
| 50 | S&F in repairs TPN DB with suitable for TPN MCB incomer, double door (IP-43), 4 Ways, built- in 100 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz, flushed in wall or fixed on surface etc. complete all as specified and as directed. |
| 51 | S&F in repairs Sheet metal enclouser Double door SPN DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 4 way 240 Volts AC flushed in wall or fixed on surface etc. complete all as specified and as directed. |
| 52 | S&F in repairs Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 100 Amps rated Single pole and neutral linkof 8 way 240 Volts AC flushed in wall or fixed on surface etc. complete all as specified and as directed. |
| 53 | S&F in repairs Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 100 Amps rated Single pole and neutral linkof 12 way 240 Volts AC flushed in wall or fixed on surface etc. complete all as specified and as directed. |
| 54 | S&F sheet metal enclosure for VT DB TPN, 4 way (with MCCB as INCOMER), double door with 63 Amps, 25 KA,TP MCCB as incomer (Vertical type double door, 63 Amps MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing etc. complete all as specified and as directed by Engr-in-charge. |
| 55 | S&F sheet metal enclosure for VT DB TPN, 6 way (with MCCB as INCOMER), double door with 63 Amps, 25 KA,TP MCCB as incomer (Vertical type double door, 63 Amps MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing etc. complete all as specified and as directed by Engr-in-charge. |
| 56 | S&F in repairs 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 5 To 32Amps capacity in the MCB DB complete with connection testing and commissioning etc. complete all as specified and as directed by Engr-in-charge. |
| 57 | All as per item No 56 above but DP 16-32 Amps etc. complete all as specified and as directed by Engr-in-charge. |
| 58 | S&F in repairs 415V, 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 To 63 Amps. capacity in the MCB DB complete with connection testing and commissioning etc. complete all as specified and as directed by Engr-in-charge. |
| 59 | M&L in repairs for sub main wiring along with earth wire of size two run of 2.5 Sqmm + one run of 2.5 Sqmm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC casing caping on surface of wall/roof .(Note Three run of 2.5 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length etc. complete all as specified and as directed. |
| 60 | M&L in repairs for sub main wiring along with earth wire of size two run of 6 Sqmm + one run of 6 Sqmm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC casing caping on surface of wall/roof .(Note Three run of 6 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length etc. complete all as specified and as directed. |
| 61 | M&L in repairs for sub main wiring along with earth wire of size two run of 4 sqmm + one run of 4 Sqmm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC casing caping on surface of wall/roof .(Note Three run of 4 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length etc. complete all as specified and as directed. |
| 62 | M&L in repairs for sub main wiring along with earth wire of size two run of 6 sqmm + one run of 6 Sqmm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC conduit concealed in wall/roof .(Note Three run of 6 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length etc. complete all as specified and as directed. |
| 63 | M&L in repairs for sub main wiring along with earth wire of size two run of 4 sqmm + one run of 4 Sqmm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC conduit concealed in wall/roof .(Note Three run of 4 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length etc. complete all as specified and as directed. |
| 64 | M&L in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep etc. complete all as specified and as directed. |
| 65 | All as per item No 64 above but of size 175 x 100 x 50 mm etc. complete all as specified and as directed. |
| 66 | All as per item No 64 above but of size 200 x 150 x 50 mm etc. complete all as specified and as directed. |
| 67 | M&L in repairs Hylam Sheet including suitable size of 04 Nos brass screws and cutting of hylam sheet for mounting, switches, sockets, fan regulator etc. of size 100 mm x 100 mm and 3 mm thickness etc. complete all as specified and as directed by Engr-in-charge. |
| 68 | All as per item No 67 above but of size 175 x 100 x 3 mm etc. complete all as specified and as directed by Engr-in-charge. |
| 69 | All as per item No 67 above but but of size 200 x 150 x 3 mm etc. complete all as specified and as directed by Engr-in-charge. |
| 70 | S&F in repairs unservicable broken/burnt ventilation fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete including dismantling of broken fan and deposit to MES store etc. complete all as specified and as directed. |
| 71 | S&F in repairs on surface medium grade non-metallic PVC casing caping of size 25 mm including of all tees, bends, elbows and fixing accessories such as couplers, lock nuts, saddles, pipe hooks including taking down old broken PVC Casing caping and making good surface by plastering and 2 coat of paint etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 72 | S&F in repairs on surface medium grade non-metallic PVC casing caping of size 25 mm including of all tees, bends, elbows and fixing accessories such as couplers, lock nuts, saddles, pipe hooks including taking down old broken PVC Casing caping and making good surface by plastering and 2 coat of paint etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |