| 1 | Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid, bedded and pointed in any mortar and removal of rubbish outside MoD land, complete all as specified and directed. |
| 2 | Demolition of cement concrete in ground floor and paving not exc. 15cm thick (below or above ground level) and removed from site outside MoD land work etc, complete all as specified and directed. |
| 3 | Material and labour for 75mm PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection and all other similar works finishing the cement concrete surface even and smooth without using extra cement, complete all as specified and directed. |
| 4 | Material and labour for MIXED CEMENT CONCRETE DELIVERED ON BUNKER M-20, type-1, 1:11/2:3 (20 mm graded aggregate) as in flooring and all other similar works, complete all as specified and directed. |
| 5 | Material and labour for cement concrete type D-2, 1:4:8 (40 mm graded aggregate in foundations, filling and mass concrete, complete all as specified and directed. |
| 6 | Material and labour for providing precast cement concrete type B-1, 1:2:4 (20 mm graded aggregate) set in cement mortar 1:4 in road side kerb stones of any shape & size and all other similar works, complete all as specified and directed. |
| 7 | M&L for PCC 1:2:4 type B-0 (using 12.50 mm graded stone aggregate) as in coping, lintel, plinth course, bed concrete and all other similar works including necessary formwork, complete all as specified and directed. |
| 8 | Material and labour for providing cement concrete type C-2 (1:3:6) 40 mm graded aggregate as in surface channels and drains finished even and smooth, complete all as specified and directed. |
| 9 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demoletion of any description and in any position not otherwise specifically provided for incl removing debris from MoD land, complete all as specified and directed. |
| 10 | M&L for RCC Type B-1, 1:2:4 (20mm graded aggregate) as in Slabs supported on walls, and all other similar works, complete all as specified and directed. |
| 11 | M&L for Mild steel bars TMT 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to complete, complete all as specified and directed. |
| 12 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick, complete all as specified and directed. |
| 13 | M&L for cement concrete type C-2, 1:3:6, 40 mm graded aggregate) in sub base, complete all as specified and directed. |
| 14 | Material and labour for crushed sand filling under precast interlocking paver blocks and all other similar works, complete all as specified and directed. |
| 15 | M&L Rubber moulded glossy finished 60 mm thickness precast concrete interlocking paver block of any shape and size confirming to IS 15658 -2006 of M-35 Grade with grey cement and pigment laid over sand cushning including compaction of paver blocks using surface vibrator, complete all as specified and directed. Note:- Sand cushioning shall be measured and paid seperately. |
| 16 | M&L for Cement concrete tiles 25cm x 25cm, 20-22mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished,, complete all as specified and directed. |
| 17 | M&L Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in Cement mortar 1:6, complete all as specified and directed. |
| 18 | M&L for any coloured vitrified heavy duty outdoor anti skid tiles 14-15 mm thick (Square/rectangular) polished area of each tile exc 0.09 Sqm and not exc 0.36 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles and including 20 mm thick in cement plaster in CM (1:4) for fixing tiles, complete all as specified and directed. |
| 19 | M&L 18-20mm thick Granite (of any type) machine cut in, wall lining, steps, jambs, pillars, window cills, skirting/dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing and including rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM (1:4), complete all as specified and directed. |
| 20 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 21 | Supplied and fixing of Mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to FE 290 Gde -E-165, complete all as specified and directed. |
| 22 | S&F Rolled mild steel for joist, channel, angle, tee sections or MS Flats fixed independantly without connecting plates, etc Fe 410-W (Gde-E- 250) quality- A (cut to ordinary lengths i.e within 20mm of length indicated) as in frame work for Galvalume / CGI chajjas, complete all as specified and directed. |
| 23 | S & F of Mild steel 0.80mm thick, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and directed. |
| 24 | M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 25 | M&L for SS 304 grade stainless less tubing (Square/ Round/ Rectangular) of suitable gauge as in SS guard bars, railings, SS frame works including all fixing arrangments, including taking down of old SS guard railing, complete all as specified and directed. |
| 26 | Material and labour for preperation of old / new concrete kerb stone surfaces and applying two coats of retro-reflective enamel paint of any colours and pattern, complete all as specified and directed. |
| 27 | Demolition of brick work including all quoins, arches,pillars etc. but excluding ashlar facings built in cement mortar and removal of rubbish outside MoD land, complete all as specified and directed. |
| 28 | M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6, complete all as specified and directed. |
| 29 | All as per item No. 28 mentioned here in above but except bricks.(Serviceable bricks obtained from Item No. 27 above to be reused.) |
| 30 | M&L for Precast cement concrete block masonary with solid blocks with 390x190x190 mm size exc 10 cmm in width and settting in mortar 1:4 type C-1 (1:3:6), complete all as specified and directed. |
| 31 | Cleaning of open drains completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains n.exc 30cm, complete all as specified and directed. |
| 32 | Cleaning of open drains completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains exc 30 cm but n.exc 60 cm, complete all as specified and directed. |
| 33 | Cleaning of open drainscompletely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains exc 60 cm but n.exc 75 cm, complete all as specified and directed. |
| 34 | Cleaning of drains/culverts including removing & re-covering of RCC/CI/Steel covers by completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains n.exc 30cm, complete all as specified and directed. |
| 35 | Cleaning of drains/culverts including removing & re-covering of RCC/CI/Steel covers by completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains exc 30 cm but n.exc 60 cm, complete all as specified and directed. |
| 36 | Cleaning of drains/culverts including removing & re-covering of RCC/CI/Steel covers by completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for width of drains exc 60 cm but n.exc 75 cm, complete all as specified and directed. |
| 37 | S & F in repair 900mm x 600mm FRP manhole cover of 20 ton loading capacity with frame over manhole coping concrete, complete all as specified and directed. |
| 38 | Extra for forming fair finished drain or channel over 30 cm inner girth in cement concrete, using extra cement, including forming moulds, mitered/stopped ends etc, complete all as specified and directed. |
| 39 | Taking down cement plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water and removal of rubbish outside MoD land, complete all as specified and directed. |
| 40 | M & L for Ready mix plaster for internal/external wall rendering 12-15mm thick in two coats of base coat and finishing coat on brick wall or concrete surfaces and making groove of appropriate size and finishing sand faced finished using sponge, including use of scaffolding, complete all as specified and as directed.Make: M/s Ultratech Cement / M/s Sound buildcare / or other approved equivalent make. |
| 41 | M&L for Preparing New surfaces of walls/ceilings by and applying two coats of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer and scaffolding where required at any height for external painting, complete all as specifed and directed. |
| 42 | M&L for Preparing old surfaces of walls/ceilings by and applying two coats of weather proof acrylic exterior paint (100% Acrylic) incl scaffolding where required at any height for external painting, complete all as specifed and directed. |
| 43 | M & L for filling cracks by cutting 'V' groove cracks of internal or external plaster of walls, ceilings/Chajjas all along the crack upto 10 mm and remove the loose plaster/concrete by suitable tools, filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat and for external application must be coated with paint including necessary scafolding of any hieght, complete all as specifed and direcetd.Make : Use of Dr Fixit Crack 'X' shrinkfree paste compound/ Smartcare Texture Crack Filler / Build Core Compound / Fosroc Compound, as approved by GE |
| 44 | M&L for applying two coats of Acrylic Elastomeric Waterproof Coating of weather proof paint (Rain coat select of Dr. fixit or equvalent), over a coat of Dr. Fixit primeseal or equivalent wall primer on new surface, complete all as specified and as per manufacturer's instruction. |
| 45 | M & L for preparation of old painted steel surfaces of any description not otherwise described over 10cm in width or girth and applying one coat of synthetic enamel paint at any height including use of scaffolding where required for external painting of steel surfaces, complete all as specified and directed. |
| 46 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr depth for cesspits, manholes etc. and getting out soft/loose soil even in foul position, complete aii as specified and as direcetd. |
| 47 | Returning, filling including spreading leveling watering and well ramming in layers n. exc 25 cm in soft/loose soil, complete all as specified and directed. |
| 48 | Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and directed. |
| 49 | Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar 200mm dia, complete all as specified and directed. |
| 50 | Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar 300mm dia, complete all as specified and directed. |
| 51 | S&F 200 mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars, complete all as specified and directed. |
| 52 | S&F 300 mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars, complete all as specified and directed. |
| 53 | S&F in repair 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls, complete all as specified and directed. (Note : upto any height and including necessary scafolding). |
| 54 | S&F in repair 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls, complete all as specified and directed. Note : upto any height and including necessary scafolding). |
| 55 | M&L for PCC 1:3:6, type C-2 using 40mm graded stone aggregate as in bed to drain pipes of 200 mm bore dia including packing uner and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 56 | All as per Item No. 55 bove but 300 mm bore. |
| 57 | S&F in repair 75mm dia PVC (SWR) bends with access doors any radius, complete all as specified and directed. |
| 58 | S&F in repair 110 mm dia PVC (SWR) bends with access doors any radius, complete all as specified and directed. |
| 59 | S&F in repair 75 mm dia PVC (SWR) junction single, (single T) equal or uequal provided with access door, complete all as specified and directed. |
| 60 | S&F in repair 110 mm dia PVC (SWR) junction single, (single T) equal or uequal provided with access door, complete all as specified and directed. |
| 61 | S & F in repair 75mm PVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and directed. |
| 62 | S & F in repair 110 mm PVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and directed. |
| 63 | S & F in repair 75 mm PVC (SWR) branch piece, (double Y) equal or unequal, complete all as specified and directed. |
| 64 | S & F in repair 110mm PVC (SWR) branch piece, (double Y) equal or unequal, complete all as specified and directed. |
| 65 | S&F in repair 75 mm dia PVC (SWR) vent cowl, complete all as specified and directed. |
| 66 | S&F in repair 110mm dia PVC (SWR) vent cowl, complete all as specified and directed. |
| 67 | M&L for refixing of chequred tiles of any type and size including prepration of sub base and also including 20 mm thick screed bed in CM 1:4, including takind out distrubed, loose or broken tiles, complete all as specified and directed. |
| 68 | M&L for refixing of interlocking tiles including prepration of sub base and also including including 25mm thick sand cushion incl watter and ramming (Compacted) and joints filled with sand, complete all as specified and directed. |
| 69 | S&F in repair of heavy duty cast iron manhole cover including frame of suitable size, complete all as specified and directed. |
| 70 | Material and labour for providing fibre-reinforced cement concrete type B-2, 1:2:4 (40 mm graded aggregate) mixed with Dr Fixit hardner in foundation filling and mass concrete, complete all as specified and directed. |
| 71 | Removal of debris outside of the MoD land, complete all as specified and directed by Engr-In-Charge. |
| 72 | Dismantling AC sheet sheeting, any gauge, thickness, roof coverings including scafoldings of any hieght, complete all as specified and directed. |
| 73 | Supply & fix Pre-painted galvalume aluminium zinc coating GI based trapezoidal/mangalore tile profile roofing sheets, chajjas, 0.50 mm thick of any colour/length having tensile strength of 550 MPA as in roof coverings having effective & overall width 1015 mm &1072 mm respectively, profile hieght 28.50 mm and centre to centre distance between ribs 203 mm fixed with self tapping screws as directed by manufacturer on wooden/steel members including scafoldings of any height of the bldg, complete all as specified and directed. |
| 74 | Supply & fix Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPA as in roof coverings /claddings to wall, fixed with self tapping screws including scafoldings of any hieght, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 75 | Supply & fix Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPA as in roof coverings /claddings to wall, fixed with self tapping screws including scafoldings of any hieght, complete all as specified and directed. Please Enable Macros to View BoQ information |