| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 2 | Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : (i) Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original surface and nothing extra shall be paid on this account. (ii)Unit rate is inclusive of cutting chases in wall /foor/PCC for sunken box and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 3 | All as per serial item 02 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed |
| 4 | All as per serial item 02 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed |
| 5 | All as per serial item 02 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 6 | Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 7 | All as per serial item 6 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed |
| 8 | All as per serial item 6 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed |
| 9 | All as per serial item 6 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 10 | Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed. |
| 11 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed. |
| 12 | Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. |
| 13 | Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
| 14 | Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. |
| 15 | Modular switch type bell push, single pole, 230 volt one module,(ISI marked) complete all as specified and directed. |
| 16 | Electric Bell, multi music type, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge. |
| 17 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge. |
| 18 | Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
| 19 | LED Bulb 09 watt self ballasted Retrofit type lamp with PBT body shell and DC diffuser CCT 6500 K complete all as specified and directed. |
| 20 | LED Lights fitting 1 x 18/20 Watt, 4 feet ,220V AC decorative type including fitting fixed on wall/ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection fixed as in repair complete all as specified and directed. |
| 21 | Slim LED lights fitting, 4 feet, 1x 20W, inverter rechargeable, inbuilt lithium ion battery with charging time 8 to 10 hrs & back upt time minimum 8 hrs, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed. |
| 22 | LED Lights fitting 1 x 9/10 Watt, 2 feet ,220V AC decorative type including fitting fixed on wall/ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection fixed as in repair complete all as specified and directed. |
| 23 | LED Industrial outdoor type Bulkhead luminaires,IP rating not less than 45, highly resistant to dust and water 1 x 9/10 Watt fitting in engineering plastic housing with clear prismatic diffuser complete with all accessories and connecting up with flexible cable white of suitable size and making necessary connection fixed as in repair complete all as specified and directed. |
| 24 | LED 12 W recess mounted indoor type back lit downlighter suited for any modern workspace of size not less than 6\\" round/square, fixed as in repair complete all as specified and directed. |
| 25 | Decorative, wall mounting, brushed nickel finish fixture with Single opal glass diffuser including 1 x 9W LED lamp B22 base, perfect ambience for living/bedroom fixed as in repair complete all as specified and directed. |
| 26 | LED Mirror Lights fitting 17 watt cool/ warm white of approx size near to 534 x 93 x 33 mm , 220V AC decorative/model ultron type including fitting fixed on wall/ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection fixed as in repair complete all as specified and directed. |
| 27 | Decorative, wall mounting fixture, in durable plastic body & designer mesh in gold finish suitable for 9 W LED lamp pettren Glaze type as per sample fixed as in repair complete all as specified and directed. |
| 28 | LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection incl mounting bracket of suitable size and connection fixed as in repair complete all as specified and directed. |
| 29 | Taking down carefully old unserviceable ceiling fan/wall fan/exhaust fan complete removing its blade and deposit to the MES store yard complete all as specified and directed. |
| 30 | Taking down carefully old unserviceable Geyser of any capacity complete removing and keeping in safe custody by Contractor and refixing the same after completion of B/R work complete all as specified and directed. |
| 31 | Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. |
| 32 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit , complete all as specified and directed. |
| 33 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit complete all as specified and directed. |
| 34 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit complete all as specified and directed. NOTE FOR SERIAL ITEM NO 32 to 34: (i) Two runs of cable, one run of earth wire shall be considered as one running metre(ii) Cutting chases & Conduit will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 35 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . |
| 36 | 20 to 25 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, complete all as specified |
| 37 | Taking down old unserviceable piano type switches , sockets, regulator etc with or without sunken box and removing materials to store and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 38 | Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), fixed as in repair complete all as specified & directed. |
| 39 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), fixed as in repair complete all as specified & directed. |
| 40 | Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), fixed as in repair complete all as specified & directed. |
| 41 | Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), fixed as in repair complete all as specified & directed. |
| 42 | Modular switch type stepped fan regulator, single pole, 230 volt two module fixed as in repair complete all as specified & directed. |
| 43 | Modular switch type bell push, single pole, 230 volt one module,(ISI marked) fixed as in repair complete all as specified & directed. |
| 44 | Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, Complete all as specified and directed . |
| 45 | MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal and maganetic release, with proper thimble complete all as specified and directed |
| 46 | Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . |
| 47 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, (2 + 10 way) 12 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 48 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, (2 + 6 way) 8 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 49 | MCB, SP , 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 50 | MCB, SPN , 240 volt, 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 51 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 52 | Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Volts for AC/Geyser point complete all as specified and as directed. |
| 53 | Casing capping with fixing accessories of size 20mm width fixed as in repair complete all as specified and directed . |
| 54 | PVC insulated and unsheathed FRLSH cable of size 1.5 sqmm, fixed as in repair compelte all as specified and directed. |
| 55 | PVC insulated and unsheathed FRLSH cable of size 2.5 sqmm, fixed as in repair compelte all as specified and directed. |
| 56 | Supply, lying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor , served with inner sheating of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, 10 Sq mm , one twin core cable flat or circualr, including taking out old service cable complete all as specified and directed. |
| 57 | Sheet metal enclosure of size of size of 915mm x 610mm x 200mm thick with locking arrangement and provn of 04 Nos glass 75mmx 150mm size in front door for measuring meter reading , flush to wall for fixing of 04 nos energy meter including taking down carefully energy meter including connection complete all as specified and directed. |
| 58 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete all as specified & directed. Please Enable Macros to View BoQ information |