| 1 | Taking of existing cover of septic tanks/soak well & cleaning of septic tank/soak well of any size/capacity by mechenical sewage sucking pumping machine and transport the sludge in to a mechanical sewage carrier tank for removing the same to a distance 10 to 15 KM from defence land and placing back in position the removed cover complete all as spd and directed by Engineer-in-Chage.Note :- (i) Net quantity of sludge as removed shall be measured and paid.quoted by the contractor.(ii) The excavation and earth work of pit in any type of soil is deemed to be included in the unit rate quoted by contractor.(ii) No extra payment shall be made for dewatering and cleaning with water which shall deemed to be included in the unit rate of this item. Net quantity of sludge as removed shall be measured and paid as quoted by the contractor. |
| 2 | Cleaning of blocked sewer/sewage line of any discription(SGSW/RCC/CI pipe) of 100mm/150mm/200mm dia or any dia at any depth by rodding or by mechenical means and well flushing the complete sewer line with water from manhole to manhole to the entire satisfaction of Engineerin-charge with and including taking out and re-fixing of manhole covers where required complete all as specified and directed. |
| 3 | Taking off existing manhole cover & cleaning of manhole (any size/depth) by dewatering and taking out rubbish/sludge etc by mannual or by mechnical means and removing the same to a distance n. exc 50 mtr distance and put into newly excavated earth and placing back in position the removed cover complete all as specified |
| 4 | Cleaning of blocked / chocked Nahani Trap/ floor trap/ Chocked WC including drain/ sewer/sewage line of any discription(SGSW/RCC/CI pipe) of 100mm/150mm/200mm dia or any dia at any depth by rodding or by mechenical means and well flushing the complete sewer line with water upto first manhole to the entire satisfaction of Engineerin-charge with and including taking out and re-fixing of manhole covers where required complete all as specified and directed. |
| 5 | Excavation over areas not exc 1.5 m deep and getting out in hard / dense soil complete all as specified and directed. |
| 6 | All as per item No. 05 above here in before but depth exc 1.5 m and n. exc 3.0 m deep. |
| 7 | Excavating in trenches, n exc 1.5m wide and n exc 1.5 m depth; for foundation, etc. or for shafts, wells, cesspits, manholes,pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 8 | Returning filling in including spreading, levelling, watering and well ramming in layers n exc. 25cm in soft/loose soil complete all as specified and directed. |
| 9 | Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 10 | M&L loose filling with broken bricks of guage 80 to 150mm in soakage pits / soakage wells complete all as specified and directed. |
| 11 | Demolition of cement concrete bed in hauching and breaking up drain pipes SGSW set in cement mortar of 100mm dia complete all as specified and directed. |
| 12 | Demolition of cement concrete bed in hauching and breaking up drain pipes SGSW set in cement mortar of 150mm dia complete all as specified and directed. |
| 13 | Demolition of cement concrete bed in hauching and breaking up drain pipes SGSW set in cement mortar of 200mm dia complete all as specified and directed. |
| 14 | Demolition of cement concrete bed in hauching and breaking up drain pipes SGSW set in cement mortar of 300mm dia complete all as specified and directed. |
| 15 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in bed to drain pipe 100mm bore including packing under and hauching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 16 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in bed to drain pipe 150mm bore including packing under and hauching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 17 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in bed to drain pipe 200mm bore including packing under and hauching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 18 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in bed to drain pipe 300mm bore including packing under and hauching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 19 | M&L for 100mm bore SGSW drain pipe grade A laid in trenches and jointed in CM 1:1 complete all as specified and directed. |
| 20 | M&L for 150mm bore SGSW drain pipe grade A laid in trenches and jointed in CM 1:1 complete all as specified and directed. |
| 21 | M&L for 200mm bore SGSW drain pipe grade A laid in trenches and jointed in CM 1:1 complete all as specified and directed. |
| 22 | M&L for 300mm bore SGSW drain pipe grade A laid in trenches and jointed in CM 1:1 complete all as specified and directed. |
| 23 | Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 24 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 25 | M&L for precast RCC 1:2:4 type B1 using 20mm stone aggregate as in landings, cover slabs, for manholes etc and similar articles with plain faces set in cement mortar 1:4 complete all as specified and directed. |
| 26 | Mild steel TMT bars 8 mm t0 10 mm dia and over cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed . |
| 27 | M&L for cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed . |
| 28 | M&L Providing PCC 1:2:4 Type B-1(using 20mm greded stone aggregate) as in coping etc.including necessary form work complete all as specified and as directed. |
| 29 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed . |
| 30 | Material & labour for brick work with sub class B old size burnt bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specifie and directed |
| 31 | M&L for brick work with fly ash bricks old size , straight or curved on plan exc 6 m mean radius , built in cement mortor 1:6 complete all as specified and directed . |
| 32 | M&L for Brickwork with flyash bricks, straight or curvedon plan to any radius in half brick thick walls,built in, built in cement mortar (1:6) complete all as specified and directed. |
| 33 | Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landing horizontal or slopping similar work not. exc 200mm thick, and flat fair finished surfaces complete all as specified and directed. |
| 34 | M&L for reinforced cement concrete 1 :2 : 4 type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs, and in shelves and the like complete all as specified and directed . |
| 35 | Taking down cement or cement plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 36 | M & L for rendering 15mm thick in CM 1:4 on brick work or concrete sufaces including finished even and smooth using extra cement. |
| 37 | Dismantling PVC pipes (110/75mm) jointed in cement mortar and taking out of trenches/from walls including fittings as bends, branch pieces, traps etc complete all as specified and directed. |
| 38 | S&F PVC (SWR) 110mm bore bends any radius complete all as specified and directed. |
| 39 | S&F PVC (SWR) 75mm bore bends any radius complete all as specified and directed. |
| 40 | S&F PVC (SWR) 110m bore junction double, (Double T) equal or unequal complete all as specified and directed. |
| 41 | S&F PVC (SWR) 75m bore junction double, (Double T) equal or unequal complete all as specified and directed. |
| 42 | S&F in repairsPVC (SWR) 110 mm bore of pipes double socketed in any length with rubber ring joints fixed to walls |
| 43 | S&F in repairsPVC (SWR) 75 mm bore of pipes double socketed in any length with rubber ring joints fixed to walls |
| 44 | S&F PVC (SWR) gully trap 125/110 mm , setting and jointing with solvent cement complete all as specified and directed. |
| 45 | S&F 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking up or down existing GI tubing complete all as specifed and as directed. |
| 46 | S&F 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking up or down existing GI tubing complete all as specifed and as directed. |
| 47 | S&F in repair Vitreous China wash basin, white, flat back, size 450x300mm excluding taps, waste chain and plug and porcelain stopper but including brackets 32 mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed |
| 48 | S & F in repairs vitreous china white squatting pan \\"Orissa Pttern\\" size 580x440mm, with integrated foot rest (excluding flushing sistern, flush pipe etc) including making good to floor complete, all as specified and directed. |
| 49 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (including 6 mm dia 50 mm long fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut) with Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device including PVC valveless, syphonic action type, flushing cistern 10 LTRS CAPACITY, low level, white, with inlet, ball valve, float and handle including brackets fixed in repairs with 32 mm PTMT Flush pipes to pedestal pan, including all joints |
| 50 | S&F in repair 10 litre capacity PVC valveless syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets Make: Prayag or equivqlent complete all as specified and directed . |
| 51 | M&L for PCC 1 : 5 : 10 Type E-2 (using 40 mm graded stone aggregate), as in sunken floor fillings and mass concrete, complete all as specified and as directed. |
| 52 | M&L for Rendering 10 mm thick in CM 1:3 on fair faces of brick masonry or concrete surfaces by using water proofing liquid compound as per manufacturer instructions, finished even & smooth without using extra cement in sunken portion complete all as specified and as directed. Note: Liquid water proofing compound shall be measured and paid separately under respective items complete all as specified and as directed. |
| 53 | Providing and applying two coats of Brushbond-acrylic polymer modiifed cementtations water proof coating after cary out proper surface preparation including removing loose comncrete, foreign materials, cleaning of concrete surface, etc pre dampning of concrete surface, mixing all components of Brush bond using heavy duty slow speed drill fitted with mixing paddle followd by application of two coats using a suitable brush as per manufacturer's instructions complete all as specified and as directed. |
| 54 | Dismantling floor hearth or wall tiling including cement mortar bedding and rubbish of the premises complete all as directed. |
| 55 | M & L for providing 25 mm thick PCC 1:2:4 Type B-2 (using 20 mm graded stone aggregate) as in flooring including finishing the cement concrete surface even and smooth with using extra cement complete all as directed. |
| 56 | M&L joint free colored non skid ceramic tiles 6 to 7 mm thick (square or rectangular) area of each tile not exc 0.38 Sqm in floors etc set and jointed in neat cement slurry and pointed in site or colored cement to match over 15mm cement screed bed in cement mortar 1:6 as specified and directed |
| 57 | M&L coloured glazed ceramic tiles 300x450x6 to 7mm thick, in floors etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles including rendering 10mm thick in CM 1:4 complete all as specified and directed. |
| 58 | Disconnecting existing tanks of capacity exc 250 & not exc 500 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re- fixing in poistion including cleaning and removing all the scale and dirt, etc from tank from months of circulating pipes etc and writing the date as \\" Tank Cleaned on (cleaning date)\\" white or black thick syntetic enamel paint complete all as specified and as directed. |
| 59 | All as per Item No 58.00 above but capacity of exc 500 & not exc 1000 ltrs complete all as specified and as directed. |
| 60 | M&L for sand filling under floor or in foundation including watering and consolidation etc complete all as directed. |
| 61 | M&L for machine pressed precast conctete interlocking paver block, rubber finished any colour,shape and size confirming to IS 15658-2006 of 60 mm thickness,with grey cement and pigment M-35 Grade etc complete all as directed. |
| 62 | M & L for chequred cement concrete tiles colour glessy finished rubber pressed 30 cm x 30 cm x 25 mm thick set jointed and pointed in neat cement slurry and pointed in coloured pigment over 20mm cement screed bed in cement mortar 1:6 complete all as specified and directed. |
| 63 | S&F in repairs single lever Basin Mixer without popup waste with 450mm Long braided hoses complete all as specified and directed. |
| 64 | S&F in repairs Bowl with cistern for couple WC with PP normal close slim seat cover, Hinges, Fixing accessories and accessories Set, size 395X680X770mm, P/S Trap-180mm/ 220mm complete all as specified and directed. |
| 65 | M & L 75mm thick Plinth Protection PCC (1:3:6) type C1 using 40mm graded aggregate (0.75 m wide) work complete all as specified and as directed. |
| 66 | S&F in repairs Toilet Paper holder fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. |
| 67 | S & F PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed. |
| 68 | S&F Soap dish (polycarbide) fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. |
| 69 | S&F in repairs towel rack complete all as specidied and directed. |
| 70 | S&F in repairs towel Rail complete all as specidied and directed. |
| 71 | S&F in repairs towel ring complete all as specidied and directed. |
| 72 | S&F Hand shower (health Faucet) with 1 Meter Long Easy Flex Tube in Chrome Finish & wall Hook with NRV (back flow Preventer) all as specified and directed |
| 73 | S&F in Repairs Angular Stop Cock with wall Flange complete all as specified and directed. |
| 74 | S&F Stop valves/Gate valve 20mm cast copper alloy,screwed down,high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all a specified and directed. |
| 75 | S&F in repairs 2 way bib cock with wall fange complete all as specified and directed. |
| 76 | S&F in repairs Wall mixer with provision for Overhead Shower with 115mm Long bend pipe on Upper Side, connecting Legs & wall Flanges (including shower) complete all as specified and directed. |
| 77 | S&F in repair brass CP fancy type 15mm bore pillar tap complete all as specified and directed. |
| 78 | S & F in repair Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed 15 mm size all as specified and directed. |
| 79 | S&Fin repairs floor trap/Nahani trap 110 mm dia with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and directed |
| 80 | S&F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 81 | S&F in repair wall cabinet Mirror (500x400Appx) complete all as specified and directed. |
| 82 | Dismantling water tanks of capacity exc 250 and n exc 500 ltrs and removing to stote complete all as specified and directed. |
| 83 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 500 ltrs.20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) complete all as specified and directed. |
| 84 | Dismantling water tanks of capacity exc 500 and n exc 1000 ltrs and removing to stote complete all as specified and directed. |
| 85 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 1000 ltrs.20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) complete all as specified and directed. |
| 86 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed. |
| 87 | Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto complete all as specified and directed. |
| 88 | Dismantling wrought iron or mild steel work of any description not otherwise provided for and removing from site of work complete all as directed by the Engineer in Charge. |
| 89 | M & L for preparation of new steel surfaces of any description over 10 cm in width or grith and applying two coat of synthetic enamel paint over a coat of red oxide paint complete all as specified and as directed. |
| 90 | M&L for Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, cattle trap, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc using SHS,RHS, Angles or other similar frames complete specified and directed. |
| 91 | Cleaning of sludge /soil etc accumulated in existing drain and thrown away the spoil in low lying area exc 250m upto a distance of 500mall as specified and directed. |
| 92 | NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs. 38,061.00] Please Enable Macros to View BoQ information |