| 1 | Supply and erecting in true vertical position steel tubular poles 9 meter long complete with M S base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-31 with and including painting of poles with black bituminous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed. |
| 2 | M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of steel tubular pole incl form work complete all as specified and directed. |
| 3 | M & L for PCC (1: 4:8 ) type D-2 using 40mm graded stone aggregate as in bottom of pit for bed concrete of steel tubular pole incl form work complete all as specified and directed. |
| 4 | M & L for PCC ( 1:2:4) type B-1 using 20mm graded stone aggregate as in coping including all form work complete all as specified and directed. |
| 5 | M&L for MS cross arms bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. |
| 6 | M & L for Aluminium conductor, steel reinforced, overhead conductor (ACSR) including stringing, stretching and strengthening existing LT steel tubular pole including binding and jointing the conductor complete all as specified and directed.Type and Size of ACSR Conductor - (Weasel) 6/1 x 2.5mm aluminium and 1x2/59 steel |
| 7 | S&F shackle type insulator, porcelain, vitreous, white, brown or green insulator of size 75mm height and 90mm dia for working pressure 1100 volts, LT complete with insulator bolts, washers and nuts complete all as specified and directed. |
| 8 | S & F stay assembly comprising GI stay bow 400 X 14 mm, GI steel stay rod 1800 mm long X 16 mm dia with nut-bolts, washers, GI steel plate 230 X 230 X 6 mm, two Nos. thimble, loop insulator of size 65 X 90 mm clearance of hole 16 mm, stay wire of GI stay strand of size 7 X 3.15 mm fixed to stay assembly and stay clamps including necessary excavation and earth work in hard / dense soil, PCC 1:3:6 type C-2 block complete all as specified and directed. |
| 9 | M&L for stringing, stretching and strengthening of GI wire 4mm dia on LT electric lines including binding, jointing etc all as specified. |
| 10 | M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 11 | M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 40mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 12 | Supply, laying, jointing and commissioning LT XLPE 1100 volts grade as per IS 7098 heavy duty cable PVC insulated, stranded aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, floor through pipes,induct, on pole and roads etc of following sizes :- |
| 13 | (a) 120 Sqmm 3.5 core |
| 14 | (b) 95 Sqmm 3.5 core |
| 15 | (c) 70 Sqmm 3.5 core |
| 16 | (d) 50 Sqmm 3.5 core |
| 17 | (e) 25 Sqmm 4 core |
| 18 | (f) 16 Sqmm 4 core |
| 19 | (g) 16 Sqmm 2 core |
| 20 | (h) 10 Sqmm 2 Core |
| 21 | Taking out unserviceable LT cable of any type and size from pole/wall/trenches by disconnecting electric connections for repair / replacement of cable complete all as specified and directed. |
| 22 | Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exc 1.5mtr depth for laying pipe line/laying cable and getting out including trimming sides and forming bottom surface to the required level/slope etc. complete all as specified and directed |
| 23 | Removing excavated surplus soil l to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified and directed. |
| 24 | Returning, filling in, tranches including spreading, levelling, watering and well ramming in hard/dense soil in layers not exceeding 25 cm in hard/dense soil complete all as specified and directed. |
| 25 | M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.Note : Punned thickness shall be measured and paid. |
| 26 | M&L for brick protection covers laid over cables of sub class'B' bricks old size (230X115X75)mm all as specified and directed. |
| 27 | S&F plastic (moulded poly propeline) line phase separators for separating 5 Nos of over head line conductors length 1200mm with 25mm with fly nuts and clamps suitable for 1100 volts grade LT electric lines of any size fixed with over head electric lines all as specified and directed. |
| 28 | Tightening / re-stringing of existing loose / broken ACSR conductor / copper conductor or any other type of conductor of any sizes and strengthening as required at site complete all as specified and directed. |
| 29 | M&L for GI pipe light grade with all fittings fixed to pole and laid to floor/ground for mechanical protection of cable of the following sizes :- |
| 30 | (a) 80mm bore |
| 31 | (b) 50mm bore |
| 32 | (c) 40mm bore |
| 33 | (d) 25mm bore |
| 34 | Dismantling of existing LT pole any size/type from foundation in necessary earth work including dismantling of concrete MS clamps nuts, bolts, earth wire, overhead lines conductor, insulators, gaurding cradles and other accessories complete all as specified and directed. |
| 35 | Dismantling of existing stay assembly any type/size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed. |
| 36 | Dismantling/taking out old ACSR/copper conductor/GI wire any size from existing over head lines incl disconnection all as specified and directed. |
| 37 | Dismantling/taking out insulator of any size/type from existing electric LT lines all as specified and directed. |
| 38 | Dismantling/ taking out street light fitting any type/capacity complete with bracket all as specified and directed. |
| 39 | M & L for one coat of aluminium shade paint of approved quality including preparation of existing old painted surface of steel tubular poles LT complete including flat iron clamps, bracing , cross arms etc and numbering of poles with white synthetic enamel paint over a circular painted base and strip marking paint up to a height of 5 feet with black & yellow five bands with synthetic paint (strip of 1 feet height each) complete all as specified and directed. |
| 40 | Supply & Fixing LED street light fitting 30 W pressure die cast aluminium IP66 roadway luminaire with high power LED as light source and electronic driver including GI bracket light grade 25/32mm and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 2 x 2.5 core complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings. |
| 41 | Supply & Fixing LED street light fitting 45 W pressure die cast aluminium IP66 roadway luminaire with operating range from 80V AC to 440 V AC with high power LED as light source and electronic driver including GI bracket light grade 25/32/40 mm and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 2 x 2.5 core complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings. |
| 42 | Supply & Fixing LED Flood light fitting 100 W 230 V AC outdoor type pressure die cast aluminium IP66 luminaire with high power LED as light source and electronic driver with impact and corrosion resistant including clamp and GI bracket light grade and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 2 x 4sqmm core complete all as specified and directed. NOTE: The contractor must submit 5 years warranty for LED fittings. |
| 43 | Taking down old U/S junction box and Supply and fixing Junction Box made up of High quality thermoplastic polycarbonate enclosure with IP 65 degree of protection, weather proof, corrosion proof, dust proof, insulted and shock proof, fire retardant non toxic material with internally embedded gasket with 10 Amp MCB and 4 nos terminal of size 200x160x98 mm complete all as specified and directed by Engineer-in-Charge. |
| 44 | Taking out old U/S service connection cable for replacement including S&F service connection cable, 1100 volts grade heavy duty PVC insulated aluminium conductor, 16 Sqmm 2 core size, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. |
| 45 | S & F MCCB 415 Volts, 4 pole, adjustable type, 100 Ampere with breaking capacity 36 KA complete all as specified and directed |
| 46 | S & F MCCB 415 Volts, 4 pole, adjustable type, 200 Ampere with breaking capacity 36 KA complete all as specified and directed |
| 47 | S & F MCCB 415 Volts, 4 pole, adjustable type, 250 Ampere with breaking capacity 36 KA complete all as specified and directed |
| 48 | S & F on pole / wall Nature switch 02 EC with enclosure factory made suitable for 8 KW street light load single phase 240 volts and power contactor rating 40 Ampere with MCB 63 Ampere contactor and terminal block confirming to IEC – 60947 – 4 – 1 / IS – 13947 – 4 – 1 (Sensor alongwith pre-dawn switching off timer, 4 – 8 hours) infrared sensor based switch for intelligent outdoor street light control model No. SWADEEP – 02EC8kW1P, Make – KAKATIYA ENERGY SYSTEMS LTD. Or its equivalent approved make complete with and including mounting bracket, cable glands, openable doors with lock complete all as specified and directed. |
| 49 | M&L for trimming of tree branches around LT/HT over head line complete removed upto 1.0 mtr distance from over head line complete all as directed by Engr-in-Charge. |
| 50 | S & F guard cradles, make to shape, hexagonal / rectangular or any other shape as required and directed, fabricated out of 4 mm dia GI wire including 14 SWG binding wire complete all as specified and directed. |
| 51 | Supply and Fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed. |
| 52 | Material and Labour for dismantling of old feeder pillar outdoor type and Supply, install, test and commission feeder pillar box out door type complete with weather protected top canopy front and rear operated twin leaf doors and cable allay ,with locking arrangement made out of 3 mm thick sheet steel duly treated with powder coated finish, Copper bus bars in enclosed chamber complete with MC100 pedestal for grouting, PCC pedestal, rubber linings for doors with including foundation and dismantling old feeder pillar box complete with the following :- (i) Copper bus bars of capacity 200 Amps for three phases and 150 Amps for neutral . (ii) MCCB 4 P 200 A with Thermal Magnetic range. Braking capacity 36 KA (for incoming) - 1 No. (iii) MCCB 4Pole 100A 25KA - 02 Nos(Outgoing) (iv) MCB 4pole 63A C Curve - 01 Nos(Outgoing) (v) MCB SPN 63A C Curve - 02 Nos(Outgoing) (vi) Voltmeter Digital 0-500 Volts -01 No with selector switch(vii) Ammeter Digital 01 No with CTs and selector switch(viii) Timer Switch MicroRex QT11 (daily time switch)(ix) Phase indication lamp(RYB) - 01 set |
| 53 | Supply, install, test and commission feeder pillar box out door type complete with weather protected top canopy front and rear operated twin leaf doors and cable allay ,with locking arrangement made out of 3 mm thick sheet steel duly treated with powder coated finish, Copper bus bars in enclosed chamber complete with MC100 pedestal for grouting, PCC pedestal, rubber linings for doors with including foundation and dismantling old feeder pillar boxcomplete with the following :- (i) Copper bus bars of capacity 150 Amps for three phases and 100 Amps for neutral . (ii) MCCB 4 P 125 A with suitable release range. Braking capacity 36 KA (for incoming) - 1 No(iii) MCCB 4Pole 100 A 25KA - 02 Nos(Outgoing) . (iii) MCB 4Pole 63 A C Curve - 02 Nos(Outgoing) (v) Voltmeter Digital 0-500 Volts -01 No with selector switch(vi) Ammeter Digital 01 No with CTs and selector switch(vii) Timer Switch MicroRex QT11 (daily time switch)(viii) Phase indication lamp(RYB) - 01 set |
| 54 | S&F synthetic insulating mat near electric installations of size 2m x 1mX 3mm as specified and directed. |
| 55 | All as per item no 54 above but of size 2m x 1m x 2.5 mm. |
| 56 | Supply & Fix in replacement for ELECTRIC SHOCK CHART (Electric shock & its management chart) of standard size 70x50 cm drawn on wooden/ cardboard frame of approved size complete all as specified and directed. |
| 57 | Supply, fabricating and fixing of sheet metal enclosure made of 16 gauge MS sheet outdoor type of suitable size including fixing of MCCB of cap 200 Amp, 415 Volt,50Hz, 4 pole, 36 KA, AC supply with 300 Amp rated busbar on porcelain insulators for neutral link double door type with locking arrangement complete with MS angle iron frame of size 25 x 25 x 5mm with nut/bolts and PCC platform work including painting with two coat of synthetic enamelled paint over one coat of red oxide/ primer complete all as specified and directed at site. |
| 58 | All as per item No 57 here in before but Cap of MCCB 100 Amp, 4 pole, 415 volt, 50 Hz, 25 KA, AC supply, |
| 59 | M&L for testing of existing earthing sets and writing the resistance value (in ohm) clearly above the earthing pits after complete cleaning of earthing chamber, removal of near by vegetation and applying one coat of distemper/whitewash over the pit covers complete all as specified and directed |
| 60 | Surface dressing n.exc 15 cm deep incl as in any type soil including taking out all sapling shrubs, brushwood, undergrowth, roots, and trees n. exc 30 cm girth all removing to a distance n.exc 100 m from starting point complete all as specified and directed by Engr-in-charge (The area is to be carried out in and around,structches viz transformes, substations around power house and other E/M installation complete all as specified and directed |
| 61 | Supply & Fix aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 62 | Supply and fix air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. |
| 63 | Supply and fix of Earth Enhancement Compound ( 6kg of Bucket) for recharging existing earthing sets and complete testing of earthing after repair and obtaining the desire earth resistance complete all as specified and directed. Please Enable Macros to View BoQ information |