| 1 | Maintenance /servicing of VRF/ VRV system Type Air conditioners with connected AHU/ indoor units by deploying Original Equipment Manufacturer (OEM) trained & experienced Engineer/Technical staff for the following equipment located at various buildings of IWS BUILDING Area including electrical connections to inspect the operation of VRF/VRV type Air conditioners with connected AHU/ indoor units and carring out preventive maintenance as per standard practice or as per OEM recommendations, carrying out repair to defective components/ equipment, detection of leaks & rectifying the same, charging/topping up of refrigerant gas complete all as specified and directed.NOTE: Compressors, PCBs, Sensors, Rewinding of Motors, Refrigerant gas etc., will be measured & paid separately under relevant items of this BOQ. |
| 2 | Maintenance/ servicing of VRF/ VRV system Type Air conditioners with connected AHU/ indoor units by deploying Original Equipment Manufacturer (OEM) trained & experienced Engineer/Technical staff for the following equipment located at various buildings of DOCMP BUILDING Area including electrical connections to inspect the operation of VRF/VRV type Air conditioners with connected AHU/ indoor units and carring out preventive maintenance as per standard practice or as per OEM recommendations, carrying out repair to defective components/ equipment, detection of leaks & rectifying the same, charging/topping up of refrigerant gas complete all as specified and directed.NOTE: Compressors, PCBs, Sensors, Rewinding of Motors, Refrigerant gas etc., will be measured & paid separately under relevant items of this BOQ. |
| 3 | Comprehensive maintenance of VRF/ VRV system Type Air conditioners with connected AHU/ indoor units by deploying Original Equipment Manufacturer (OEM) trained & experienced Engineer/Technical staff for the following equipment located at various buildings of SSQAG BUILDING Area including electrical connections to inspect the operation of VRF/VRV type Air conditioners with connected AHU/ indoor units and carring out preventive maintenance as per standard practice or as per OEM recommendations, carrying out repair to defective components/ equipment, detection of leaks & rectifying the same, charging/topping up of refrigerant gas complete all as specified and directed.NOTE: Compressors, PCBs, Sensors, Rewinding of Motors, Refrigerant gas etc., will be measured & paid separately under relevant items of this BOQ. |
| 4 | Maintenance/Servicing of VRF/ VRV system Type Air conditioners with connected AHU/ indoor units by deploying Original Equipment Manufacturer (OEM) trained & experienced Engineer/Technical staff for the following equipment located at various buildings of LARC BUILDING Area including electrical connections to inspect the operation of VRF/VRV type Air conditioners with connected AHU/ indoor units and carring out preventive maintenance as per standard practice or as per OEM recommendations, carrying out repair to defective components/ equipment, detection of leaks & rectifying the same, charging/topping up of refrigerant gas complete all as specified and directed.NOTE: Compressors, PCBs, Sensors, Rewinding of Motors, Refrigerant gas etc., will be measured & paid separately under relevant items of this BOQ. |
| 5 | SUPPLY ONLY Compressor for 11.5 TR capacity specification should be as per existing units.Make: EMERSON/ DANFOSS or equivalent |
| 6 | SUPPLY ONLY Digital Compressor for 5 TR capacity specification should be as per existing units.Make: EMERSON/ DANFOSS or equivalent |
| 7 | SUPPLY ONLY Digital Compressor for 7.5 TR specification should be as per existing capacity units.Make: EMERSON/ DANFOSS or equivalent |
| 8 | M&L for taking down unserviceable hermetically sealed compressor after disconnecting the suction/delivery lines and Supply & fixing hermetically sealed compressor of following capacities as per existing make, model & specification, including pressure testing, vacuumising and charging of refrigerant, testing and commissioning all as directed Make : Copeland/Danfoss/kirloskar/Blue star/Voltas (As per site requirement) |
| 9 | All as per item no 08 but Capacity 2 TR |
| 10 | All as per item no 08 but Capacity 3TR |
| 11 | All as per item no 08 but Capacity 1.5TRNote: Refrigerant will be measured and paid separately |
| 12 | SUPPLY ONLY Refrigeration Gas 410-A |
| 13 | SUPPLY ONLY PC Board for out door unit 22 TR for VRF for unit. |
| 14 | SUPPLY ONLY PC board for unit 11.5TR for VRF Unit. |
| 15 | SUPPLY ONLY Temparature sensor for unit 22 TR for VRFunit. |
| 16 | SUPPLY ONLY FAN motor for unit 12.5 HP for VRF for unit. |
| 17 | SUPPLY ONLY solonoid valve for outdoor unit |
| 18 | SUPPLY ONLY VRF AHU of 25000 cfm unit ahu exapnsion KIT |
| 19 | SUPPLY ONLY VRF indoor unit Temparature sensor suitable for AHU |
| 20 | SUPPLY ONLY 4 pole contactor, 63 AmpsMAKE: L&T/SCHNEIDER/LEGRAND/C&S |
| 21 | SUPPLY ONLY 4 pole contactor, 32 AmpsMAKE: L&T/SCHNEIDER/LEGRAND/C&S |
| 22 | M&L for servicing of both indoor and out door units with coil cleaning chemical for cassatte ACs including checking of all elelctrical connectionsall as directed for the following capacity. |
| 23 | 1 x 2 TR Capacity Cassete Hi-wall split AC out door unit Make as per site. |
| 24 | 1 x 3 TR Capacity Cassete Hi-wall split AC indoor unit Make as per site. |
| 25 | 2 x 4 TR Capacity Cassete Hi-wall split AC Indoor unit Make as per site. |
| 26 | 4 x 5.5 TR Capacity Package type AC plant |
| 27 | 5 x 8.5 TR Capacity Ductable type AC |
| 28 | M&L for leak testing of the total refrigerant system of Package VRF type AC plants by pumping down the refrigerant to cylinder, flushing out the entire system arrest all leakages by replacing the damaged flare nuts, taflon washers, brazing, gaskets, o rings etc and leak test by supply and charging with Nitrogen gas ( N-2) under constant pressure of 250 - 300 PSI , watching the pressure for 24 Hrs for confirmation, flushing out the system vacuumising and charge the required qty of refrigerant and lubricant testing and commissioning the system all as directed for the following capacity of plants (Note: Refrigerant & compressor oil shall be measured and paid separately under respective items) |
| 29 | 1 x 2 TR Capacity Cassete Hi-wall split AC out door unit Make as per site. |
| 30 | 1 x 3 TR Capacity Cassete Hi-wall split AC out door unit Make as per site. |
| 31 | 2 x 4 TR Capacity Cassete Hi-wall split AC out door unit Make as per site |
| 32 | 4 x 5.5 TR Capacity Package type AC plant |
| 33 | 5 x 8.5 TR Capacity Ductable type AC |
| 34 | Taking down unserviceable liquid line filter drier and S&F liquid line filter drier as per existing make & specification and suitable size to fixing with existing refrigerant line for 10 HP to 20 HP capacity compressor of AC Plant, all as specified and directed by the Engr-in-charge |
| 35 | Removing the worn-out unserviceable blower motor following capcity of AC Plant from the position after disconnecting the electrical connections and transporting to the work shop and opening the end covers, removing the unserviceable winding, clean the slots with CTC, rewind the motor by super enameled copper winding wire of suitable gauge and size with insulating paper, insulating varnish and drying for obtaining requisite insulation values complete with necessary PVC sleeves, lead wire, new terminal block complete and bring back and install in position including testing and commissioning all as directed |
| 36 | As per Srl item no.32 of 10 HP capacity |
| 37 | Ditto as per item no 34 of 20 HP capacity |
| 38 | S&F in replacement microprocessor based control panel alongwith single phase controllers, contractors and LED display as per existing same model & specification, controlling for condensing unit, compressor unit & blower of following units , all as specified and directed by the Engr-in-charge. Make:- Voltas/Bluestar/LG/Daikin |
| 39 | Ditto as per item no 34 , 1 x 2 TR Capacity Cassete Hi-wall split AC out door unit. |
| 40 | Ditto as per item no 34 , 1 x 3 TR Capacity Cassete Hi-wall split AC out door unit. |
| 41 | Ditto as per item no 34 , 2 x 4 TR Capacity Cassete Hi-wall split AC out door unit. |
| 42 | Ditto as per item no 34 , 4 x 5.5 TR Capacity Package type AC plant |
| 43 | Ditto as per item no 34 , 5 x 8.5 TR Capacity Ductable type AC |
| 44 | Removing the chocked unserviceable copper refrigerant tubing and S&F copper refrigerant tubing for the following sizes (outer dia) including suitable joints / branch connectors and distributers with flare nuts/brazing for indoor & outdoor units as required at site complete all as specified and as directed. |
| 45 | 6.4 mm to12.7 mm |
| 46 | 15.9 mm to 22.2 mm |
| 47 | M&L for rigid PVC conduit (medium grade) size 20 to 32 mm dia for water drain out line for Package type AC plant, laid on walls, ceiling, in floors with clamping/fixing mtrls complete all as specified and directed. |
| 48 | All as per item 41 above but size 40 mm dia. |
| 49 | Supply and top up Compressorsynthetic oil of suitable grade in the refrigeration compressor to the requisite level complete all as directedMake: Freezol/servo freeze |
| 50 | Supply and filling/topping up/ charging of Refrigerent gas R-22 complete all as directed. |
| 51 | Supply and filling/topping up/ charging of Refrigerent gas R-407 complete all as directed. |
| 52 | Supply and filling/topping up/ charging of Refrigerent gas R-32 complete all as directed. |
| 53 | Supply Contactor rated current AC 3Ph, 9 Amps, coil voltage 230 V AC, 50Hz, capacity as per existing specification |
| 54 | Supply Contactor rated current AC 3Ph, 25 Amps, coil voltage 415 volts AC, 50Hz, capacity as per existing specification |
| 55 | Supply Contactor rated current AC 3Ph, 40 Amps, coil voltage 415 volts AC, 50Hz, capacity as per existing specification |
| 56 | Supply Contactor rated current AC 3Ph, 63 Amps, coil voltage 415 volts AC, 50Hz, capacity as per existing specification |
| 57 | Supply Relay switch of range 4 to 6.5 Amps |
| 58 | Supply Relay switch of range 6 to 14 Amps |
| 59 | Supply Relay switch of range 14 to 21 Amps |
| 60 | Supply Relay switch of range 40 to 63 Amps |
| 61 | Supply LED Indicator lamps of colors R / Y / B |
| 62 | Supply HRC fuse 2.5 to 10 Amps |
| 63 | Supply HRC fuse 16 to 32 Amps |
| 64 | Supply MCCB 100 Amps 25 KA Make Havells/Standard Model No SKB-7 |
| 65 | S&F in replacement Outdoor Sensors suitable for Hi-Wall split Type AC for 2 TR to 4 TR same as per at site |
| 66 | Repair / maintenance of split/Window type AC, water cooler and desert cooler in its position, testing all the components / parts, wiring etc, identifying the defective parts & reporting the JE E/M or supervisor for immediate replacement including refixing the appliances after necessary repairs , job includes replacing of any minor spares like wires, bolts, nuts pads and checking all the like air flow, temperature, smooth functioning of appliances & sealing the pipes hole, checking the drain pipe complete all as directed by Engr-in-charge.Note: (i) The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (iii) The contractor supervisor will report to concerned JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report on following day before 0900hrs to the JE E/M. |
| 67 | (iv) The contractor has to rectify the defects and make the AC of any type /water cooler/ desert cooler functional within 24 hours from the time the list of defective spares of AC of any type /water cooler/ desert cooler is handed over to him / his rep by the concerned JE E/M. In case the AC of any type /water cooler/ desert cooler is not made functional for whatsoever reason within the specified time limit, an amount of Rs 500/- per such complete pending complaint per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall engage separate team of technicians / repairer for IWS,Quality centre,ASL, DOCMP.(v) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every AC of any type /water cooler/ desert cooler and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of AC of any type /water cooler/ desert cooler with the concerned JE E/M against Sch 'A' items.(vii) The contractor should submit the copy of qualification,Experience as AC mech of any type of summer appliances and police verification certificates while sigining the site orders.(viii) The contractor is fully responsible for providing the safety standards to be maintained by the electricians while attending the AC of any type /water cooler/ desert cooler/electrical defects.(ix) The AC Mech and helpers should be properly dressed and should wear shoes, gloves and face mask while on duty, necessary hand sanitizer should be provided. Please Enable Macros to View BoQ information |
| 68 | (iv) The contractor has to rectify the defects and make the AC of any type /water cooler/ desert cooler functional within 24 hours from the time the list of defective spares of AC of any type /water cooler/ desert cooler is handed over to him / his rep by the concerned JE E/M. In case the AC of any type /water cooler/ desert cooler is not made functional for whatsoever reason within the specified time limit, an amount of Rs 500/- per such complete pending complaint per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall engage separate team of technicians / repairer for IWS,Quality centre,ASL, DOCMP.(v) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every AC of any type /water cooler/ desert cooler and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of AC of any type /water cooler/ desert cooler with the concerned JE E/M against Sch 'A' items.(vii) The contractor should submit the copy of qualification,Experience as AC mech of any type of summer appliances and police verification certificates while sigining the site orders.(viii) The contractor is fully responsible for providing the safety standards to be maintained by the electricians while attending the AC of any type /water cooler/ desert cooler/electrical defects.(ix) The AC Mech and helpers should be properly dressed and should wear shoes, gloves and face mask while on duty, necessary hand sanitizer should be provided. Please Enable Macros to View BoQ information |