| 1 | Supply, Installation, Commissioning of high quality long through100 Watt mono colour wash light, Protection Rating: IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive & Protective Equipment EN 60598-1:2015\\" and \\"Electromagnetic Compatibility Directive EN Adjustable arrangements for fixing the lights having the rotation degrees embossed in the die cast. consumption: 100W.,(As per Complete Item No. 1 of the DNIT) |
| 2 | Supply, Installation, Testing and Commissioning of 6W Mono colour Spot light, Protection Rating: IP66, complying to BIS standard \\"IS 10322 (Part 5/Sec 1): 2012\\" and having CE certification against standard \\"Low Voltage Directive Protective Equipment - EN 60598-1:2015\\" and Electromagnetic Compatibility Directive – EN 61547: 2009\\", (As per Complete Item No. 2 of the DNIT) |
| 3 | Supply, Installation, Testing and Commissioning of High quality Decorative Double Arm 2\\"50W Post Top Light, Power Input: 3000K, Pole Size: 3000mm, Pole Dia: 114 & 76mm, Material: GI Iron, Impact resistant polycarbonate/metal housing, GU24/E26 base, Protection Rating: P65, Input power: AC 110 - 230V, 50Hz.,(As per Complete Item No. 3 of the DNIT) |
| 4 | DSR Item No.5.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. |
| 5 | DSR item No.5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 6 | S/E of Thermo Plastic cable Jn. Box IP55/65 of size 210x155x92 deep (approximate) with 4 nos. thermal block suitable for 1 no. incoming and 3 nos. outgoing cables. The terminal block shall be of Hansel/ Wago/ Elmax/ Siemens make only and cable junction box shall be of Hansel make KF-1616-G or its equivalent Clipsal/ Legrand/ Rittal make only. The job includes all labour and petty material to required complete the job to the entire satisfaction of the Engineer in Charge of work. |
| 7 | Supply & laying of PVC copper wire 1.5 mm sq. 3 core round sheathed wire on existing surface with suitable clamps/ hanger etc. including making connection and petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The copper wire should be of Polycab/ L&T/ Havells/ Finolex/ R.R. Kables make only. |
| 8 | Providing and fixing of MS wire mesh for protection of LED fittings of following size 16 gauge frame with MS angle 40mmx40mmx6mm, MS flat 20mmx3mm size including cutting, welding etc. complete in all respect and to the entire satisfaction of the Engineer in Charge. The MS wire Mess should be fabricated as per size of LED fitting. |
| 9 | Size 10”X10”X10” (approx.) |
| 10 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator). |
| 11 | 4 way (4 + 12) Double door |
| 12 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 13 | Single pole |
| 14 | Triple pole and neutral |
| 15 | DSR item No.15.16 SupplyingandlayingoffollowingsizeDWCHDPEpipeISI markedalongwithallaccessorieslikesocket,bend,couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioningandprotectivecoveringetc.,completeasrequired. |
| 16 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 17 | Supply and erection of cement concrete foundation of size 12\\"x12\\"x20\\" deep after digging the ground with manual. The MS jalie shall be erected on the foundation for erection of the fitting. The cement concrete foundation shall be plastered with cement sand. The job includes cost of labour and other petty material required to complete the job to the entire satisfaction of engineer in charge of the work. |
| 18 | Supply and laying of XLPE insulated PVC sheathed Aluminum conductor cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing RCC/Hume/DWC/ Metal pipe. The job include the cost of making connections with suitable size of Aluminium Lugs/ thimbles, testing, commissioning etc. (As per Complete Item No. 13 of the DNIT) |
| 19 | Size 10 Sq.mm 4 Core XLPE Al. Arm. Cond. Cable |
| 20 | Supply and erection of sheet metal cubical pedestal of suitable dimensions made from 50 mm X 50 mm X 6 mm thick M.S angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides and front side hinged complete with locking arrangement with 4 Nos. switchgear supporting members each of M.S.(As per Complete Item No. 14 of the DNIT) |
| 21 | Cubical size 900 mm X 600 mm X 350 mm Please Enable Macros to View BoQ information |