| 1 | CONSTRUCTION OF 25 KVA 11 / 0.43 KV DOUBLE POLE MOUNTED SUB-STATION (Part A) |
| 2 | 25KVA 11/0.43 KV(AL)TransformerBISenergy Level-II |
| 3 | 9 Mtr long 300 Kg PSC Pole (For Raisin |
| 4 | G.I Base plate for PSC Pole |
| 5 | GI Channel 100 x 50 x 5 mm, 9.56 Kg / mtr |
| 6 | GI Channel 75 x 40 x 4.5 mm, 7.14 Kg / mtr |
| 7 | GI Angle 50 x 50 x 6 mm, 4.5 Kg / mtr |
| 8 | Fish Plate 50x8 mm. Each 0.280 mtr. Leng |
| 9 | Back Clamp for LTDB of length 0.801 mtr |
| 10 | Danger plate |
| 11 | Back clamp for danger plate ( 25x3 mm Flat) |
| 12 | GI Barbed wire (Anti climbing device @ 3kg/support) |
| 13 | Back clamp for Barbed wire anticlim |
| 14 | 11KV Lightening Arrestor (9 KV 10KA)DH class |
| 15 | 11KV Line AB Switch (200 Amp) 3 poles 50HZ |
| 16 | HG fuse 11KV-200A 3pole 50Hz with porceletain insulatoe(P1) |
| 17 | LT Distribution box with MCCB Aluminium Busbar of single Bay with kit-kat fuse for 25KVA S/S |
| 18 | 11 KV, 5KN pin insulator Polymer |
| 19 | Earthing device/ Support coil type (GI) |
| 20 | No-8 GI Wire (Dia 4.6mm) 0.131 KG/Mtr.2 mtr for connecting pole with coil earthing |
| 21 | HT Stay Clamp (1.9 kg/Pair) |
| 22 | HT 11KV stay set (complete) |
| 23 | HT Stay Insulator |
| 24 | 7/10 SWG G.I. Stay wire, Grade-2 |
| 25 | 1.1KV AI 1CX50 Sq.mm Un-armoured Cable |
| 26 | Gland for 1.1kv AI 1CX50 sq mm |
| 27 | Socket Crimping AL 50 Sqmm Cable |
| 28 | 11 KV H/W Fitting (T&C) 45KN |
| 29 | 11 KV Disc insulator (B&S) 45KN (Polymer) |
| 30 | Clamp PG Conductor rabbit ACSR 55 sq mm |
| 31 | Conductor 55 sq mm ACSR rabbit PVC insul |
| 32 | G.I Nuts, Bolt & washer of different size |
| 33 | 40mm nominal bore GI pipe (medium gauge) |
| 34 | 25x6mm GI Flat for earthing, 2.36kg/mtr. |
| 35 | Black Paint |
| 36 | Yellow Colour Paint for Background |
| 37 | Sundries (Paints, Danger Board, Al Binding tape & wire, Insulating cape, anti climbing device, Clamp Connector, Jumpering materials, Socket & other accessories etc.) |
| 38 | Stay concreting in ratio 1:2:4 & 0.2 CUM |
| 39 | Concreting of poles in ratio 1:1.5:3 (500mmx500mmx15) |
| 40 | Couping of poles in ratio 1:1.5:3 (500x500x450)=0.1 |
| 41 | Earth chamber, pipe install & Bentonite |
| 42 | Survey and digitization of New DSS and I |
| 43 | Fencing & Sand Filling & Metal Spreading :-1) RCC Pillar of 6 feet long 2) Cooping of Pillar with C.C Fencing size 10 nos. RCC Pillar and 3ply, G.I Barbed wire and grill (1:3:6) using 400mm HBG metal size 3) G.I Barbed wire @ 6.044 meter/kg 6 nos run= 40 ft X6= 240 ft=73.152 meter=12.10 KG 4) MS Grill gate 1.5 mtr (h) x 1.5 mtr(W) made of 35 x 35 x 6 mm angle and 25x 6 flat ( Angle for out side border with Horozontal & Vertical crossing for i) 35 X 35 mm MS Angle 1.5 meter @ 1.2 kg/ mtr = 28.8 kg iii) Painting of Gate with 2 Coat 5) filling Sand @ 1.359 Cum g) 40 mm size HBG Metal @ 0.679 cum) =I |
| 44 | 11KV CUT POINT 180° ANGLE |
| 45 | 10 Mtr long 300 Kg PSC Pole |
| 46 | Base plate for PSC pole |
| 47 | Straight Cross Arm Channel 100x50x5 |
| 48 | Fish plate 50 x 8 mm 0.97 kg/mtr , each 0.280 mtr. Length |
| 49 | Danger plate |
| 50 | Back clamp for danger plate ( 25x3 mm Flat) |
| 51 | GI Barbed wire (Anti climbing device @ 3kg/support) |
| 52 | Back clamp for Barbed wire anticlimbing |
| 53 | 11 KV, 5KN Pin Insulator (Ploymer) |
| 54 | H W fitting (B &S) 45KN,3 Bolt |
| 55 | 11 KV Disc insulator (B&S)(Ploymer) 45 KN |
| 56 | Earthing device/ Support coil type (GI) |
| 57 | No-8 GI Wire (Dia 4.6mm) 0.131 KG/Mtr.2 mtr for connecting pole with coil earthing |
| 58 | PG Clamp for 55 Sqmm AAAC |
| 59 | G.I Nuts, Bolt & washer of different size |
| 60 | HT Stay clamp |
| 61 | HT 11KV Stay Set (Complete) |
| 62 | HT Stay Insulator |
| 63 | 7 / 10 SWG Stay Wire Grade 2 forstay support for XLPE Cable |
| 64 | Black Paint |
| 65 | Yellow Colour Paint for Background |
| 66 | Stay concreting in ratio 1:2:4 & 0.2 CUM |
| 67 | Concreting of poles in ratio 1:1.5:3 (500mmx500mmx16) |
| 68 | Couping of poles in ratio 1:1.5:3 (500x500x450)=0.1 |
| 69 | 11KV CUT POINT 90° ANGLE |
| 70 | 10 Mtr long 330 Kg PSC Pole |
| 71 | Base plate for PSC pole |
| 72 | Straight Cross Arm Channel 100x50x5 |
| 73 | Fish plate 50 x 8 mm 0.97 kg/mtr , each 0.280 mtr. Length |
| 74 | Danger plate |
| 75 | Back clamp for danger plate ( 25x3 mm Flat) |
| 76 | GI Barbed wire (Anti climbing device @ 3kg/support) |
| 77 | Back clamp for Barbed wire anticlimbing |
| 78 | 11 KV Pin Insulator (Ploymer) |
| 79 | H W fitting (B &S) 45KN,3 Bolt |
| 80 | 11 KV Disc insulator (B&S)(Ploymer) 45 KN |
| 81 | Earthing device/ Support coil type (GI) |
| 82 | No-8 GI Wire (Dia 4.6mm) 0.131 KG/Mtr.2 mtr for connecting pole with coil earthing |
| 83 | PG Clamp for 55 Sqmm AAAC |
| 84 | G.I Nuts, Bolt & washer of different size |
| 85 | HT Stay clamp |
| 86 | HT 11KV Stay Set (Complete) |
| 87 | HT Stay Insulator |
| 88 | 7 / 10 SWG Stay Wire Grade 2 forstay support for XLPE Cable |
| 89 | Black Paint |
| 90 | Yellow Colour Paint for Background |
| 91 | Stay concreting in ratio 1:2:4 & 0.2 CUM |
| 92 | Concreting of poles in ratio 1:1.5:3 (500mmx500mmx16) |
| 93 | Couping of poles in ratio 1:1.5:3 (500x500x450)=0.1 |
| 94 | CONSTRUCTION OF 25 KVA 11 / 0.43 KV DOUBLE POLE MOUNTED SUB-STATION (Part D) |
| 95 | 9 Mtr long 300 Kg PSC Pole (For Raisin |
| 96 | Base plate for PSC pole |
| 97 | 11 KV 'V'cross Arm (GI) |
| 98 | GI Back clamp for 11 KV \\"V\\" cross Arm |
| 99 | 11 KV F- Clamp |
| 100 | Danger plate |
| 101 | Back clamp for danger plate ( 25x3 mm Flat) |
| 102 | GI Barbed wire (Anti climbing device @ 3kg/support) |
| 103 | Back clamp for Barbed wire anticlimbing |
| 104 | 11 KV, 5KN pin insulator Polymer |
| 105 | Earthing device/ Support coil type (GI) |
| 106 | No-8 GI Wire (Dia 4.6mm) 0.131 KG/Mtr.2 mtr for connecting pole with coil earthing |
| 107 | G.I Nuts, Bolt & washer of different size |
| 108 | Conductor 55 sq mm AAA |
| 109 | Black Paint |
| 110 | Yellow Colour Paint for Background |
| 111 | Sundrics (Paint, Danger Board, Aluminium binding tape & wire, insulating tape, anti climbing device, Clamp connector, Jumpering Materials, Socket & other accessories etc.) |
| 112 | Survey of incremental/delta network and |
| 113 | Concreting of poles in ratio 1:1.5:3 (500mmx500mmx15) |
| 114 | Concreting of poles in ratio 1:1.5:3 (500x500x450)=0.1 |
| 115 | C.Supply of service connection materials |
| 116 | LT 3 1/2 Core 35 mm2 PVC cable |
| 117 | Insulated piercing connector, Type-B- main 16 to 95 sq.mm & Tap-2.5 to 10 s.q mm. |
| 118 | Netural connector type B suitable for main 35 to 70sq mm AAAC & Tap-2.5 to 10.sq mm service cable cover by black weather resisant insulation cover. |
| 119 | NO-8 SWG GI Wire |
| 120 | 200 A Kit kat fuse |
| 121 | 40mm dia GI S/C brackets |
| 122 | Sundries Please Enable Macros to View BoQ information |