| 1 | SUPPLY OF MATERIAL |
| 2 | MS angle 65x65x6mm (fabrication of cable stand and neutral earthing stand for power T/F) |
| 3 | MS flat 50*6mm for fabrication of cable stand and neutral earthing stand for power T/F |
| 4 | Fire fighting extinguisher (6kg) of sub station as per ISI specification including mounting on wall with the help of clamp |
| 5 | Fire bucket stand with 04 no. buckets (For switchgear/control room & switchyard) |
| 6 | Rubber matt 2*1.5mtr, 3mm thick as per IS standard |
| 7 | Stone pad 300x300x75mm |
| 8 | Armoured control cable 2x2.5 MM2 |
| 9 | Armoured control cable 4x2.5 MM2 |
| 10 | Armoured control cable 6x2.5 MM2 |
| 11 | Battery charger (Floot cum boost charger) |
| 12 | Battery set 12Nos. X 2Volts, 200Ah with stand |
| 13 | G.I pipe 6\\" dia |
| 14 | \\"E\\" Bracket |
| 15 | Junction box (for control cable wiring) for CT with all necessary accessories |
| 16 | Top channel clamp |
| 17 | Dropper channel clamp |
| 18 | Bracing angle clamp |
| 19 | Stay clamp |
| 20 | Cable holding clamp |
| 21 | PG clamp for DOG conductor |
| 22 | Danger board & clamp with nut & bolt 11 kv |
| 23 | 11 kV 3x300 sqmm XLPE cable jointing kit O/D |
| 24 | 11 kV 3x300 sqmm XLPE cable jointing kit I/D |
| 25 | 11 kV 3x185 sqmm XLPE cable jointing kit O/D |
| 26 | 11 kV 3x185 sqmm XLPE cable jointing kit I/D |
| 27 | GI Barbed wire |
| 28 | Clamp for connector for 33kV switchyard (CT, ISO, T/F) |
| 29 | Break down, shut down roistaring name board |
| 30 | ERECTION OF WORKS |
| 31 | ACSR DOG conductor |
| 32 | 33 kV Post insulator |
| 33 | 33 kV Bus isolator |
| 34 | 33 kV Line isolator |
| 35 | 33 kV VCB with Steel structure |
| 36 | 33 kV CT 200/100/1A |
| 37 | 33 kV Lightening arrestor |
| 38 | 5 MVA, 33/11 kV Power Tranformer |
| 39 | 90 lbs rail pieces for T/F plinth (44.64 Kg/M) |
| 40 | Structure for L.A. |
| 41 | 11 kV Bus coupler 350MVA |
| 42 | PCC pole 8.5mtr |
| 43 | MS Top channel (100*50*6mm-2240mm) |
| 44 | Dropper channel (100*50**6mm-2028mm) |
| 45 | MS Bracing angle 65x65x6-2700 mm |
| 46 | 11 kV Pin insulator polymeric type |
| 47 | 11 kV Disc insulator Polymeric 45KN |
| 48 | 11 kV Disc fitting 45KN |
| 49 | Stay rod 16x1800 mm |
| 50 | Stay wire 7/10 SWG |
| 51 | MS earthing rod 20x2500 mm |
| 52 | 11 kV TPMO with polymer insulator |
| 53 | GI Wire 5mm |
| 54 | 11 kV fuse set with fixing clamp |
| 55 | Fire fighting extinguisher (6kg) of sub station as per ISI specification including mounting on wall with the help of clamp |
| 56 | Fire bucket stand with 04 no. buckets (For switchgear/control room & switchyard) |
| 57 | Rubber matt 2*1.5mtr, 3mm thick as per IS standard |
| 58 | Stone pad 300x300x75mm |
| 59 | Armoured control cable 2x2.5 MM2 |
| 60 | Armoured control cable 4x2.5 MM2 |
| 61 | Armoured control cable 6x2.5 MM2 |
| 62 | Battery charger (Floot cum boost charger) |
| 63 | Battery set 12Nos. X 2Volts, 200Ah with stand |
| 64 | G.I pipe 6\\" dia |
| 65 | \\"E\\" Bracket |
| 66 | Junction box (for control cable wiring) for CT with all necessary accessories |
| 67 | Top channel clamp |
| 68 | Dropper channel clamp |
| 69 | Bracing angle clamp |
| 70 | Stay clamp |
| 71 | Cable holding clamp |
| 72 | PG clamp for DOG conductor |
| 73 | Danger board & clamp with nut & bolt 11 kv |
| 74 | GI Barbed wire |
| 75 | Clamp for connector for 33kV switchyard (CT, ISO, T/F) |
| 76 | Break down, shut down roistaring name board |
| 77 | Earthing of S/s outdoor equipments:-Laying of earth mat in the switchyard by laying of M.S. Round of 32 mm dia in 500 mm deep trenches with M.S. Round 32mm dia, 3 Mtr. Long earth electrodes as per drawing. The work includes welding of the M.S. Round , connecting all steel structures in the switchyard with the earth mat by means of G.I. strips of size 50x6mm as per item below. (All required materials will be provided by contractor) |
| 78 | Earthing of S/s for indoor equipments:-Laying of Earth mate for earthing of indoor equipments by means of M.S strip 50x6mm connecting to Pipe type earthing as per norms. Joints will be welded with high quality are welding. (All required materials will be provided by contractor) |
| 79 | Plinth & foundation for T/F:-Construction of plinth of size 3.46x4.46 Mtr for 5 MVA T/F having 0.4 Mtr above ground level. The work including excavation of foundation base concreting by (cement, fine sand & brick ballast) first class brick work in cement morter foundation CC in 1:3:6 ratio (cement, fine sand & brick blast) and RCC (1:1.5:3) working (cement, coarse sand and stone grit using MS Bars of 12mm dia (tor) in reinforcement including its cutting, bending & binding in required shape.The work also includes laying of 2 nos 3.46 mts long each rail places complete with cutting welding & proper fitting etc. The plinth will be made as per norms and shall be plastered/finished on top and sides of the plinth (All required materials like sands, bricks, cement, MS bars, stone grits etc. will be provided by contractor) |
| 80 | Plinth & foundation for 33 kV VCB:-(Construction of plinth of size 2.0 mtr*1.5 mtr*0.9 mtr suitable for erection of upper structure for 33 kV VCB including grouting of anchor bolts in proper alignment and level. Scope of work includes excavation of foundation base concreting in CC (cement, fine sand & brick ballast ), 1st class brick work in cement mortor CC in ratio 1:3:6 and RCC (1:1.5:3) work (cement coarse sand and stone grit as per norms |
| 81 | Digging & Making of Pakka cable trench 450mm wide and 900 mm deep by providing cement, sand, bricks & C.C. trench cover for laying of various size of control cable (All required materials like cements, sands, bricks & C.C. trench cover etc will be provided by contractor) |
| 82 | FABRICATION OF TRANSFORMER SEPARATE EARTHING T/F NEUTRAL EARTHING;-(A) Seprate earthing of power T/F by way of boring and lowering \\"B\\" class GI pipe 2'' dia, - 3no*30 mtr deep (02 no for T/F body earthing and 01 no for T/F neutral in delta connection earthing and making earthing pit for each) by providing all materials like \\"B\\" class GI pipe 2'' dia, 50*6mm GI strip, socket, sand, charcoal, bricks, cement etc.(All required materials will be provided by contractor). (B) Fabrication and grouting of M.S Channel 100*50*6mm in L- shape & in proper size and alignment to provide support for the two separate earthing strips 50*6mm size for power transformer neutral including supply and fixing of two nos. Flexible copper bonds for neutral earthing. |
| 83 | Fabrication and erection of cable support made of two pieces of M.S channel 100x50mm,3.0 Mtr. long joined to each other by means of 5 Nos.M.S Flat 50x6mm places of size 150mm long each by welding at equal intervals and grouting in a block of size300x300x700mm complete with one coat of ready mixed primer and two coats of alluminum paint. This includes provinding of four nos M.S clamp made of M.S flat holding the cable including nuts and bolts and fixing of XLPE cable. (All required materials will be provided by contractor) |
| 84 | INSTALLATION OF 11kV SWITCHGEARS & CONTROL PANEL IN CONTROLROOM:- (A) Shifting carefully & safely 11kV 01 No I/C, 02 NoO/G & 01 No bus coupler switchgear from outside of the switchgear room as per direction of Engineer in charge, placing and fixing of switchgear on foundation providing G.I. Nuts & Bolts of proper size in proper position and alignment and checking, complete work with Mounting of P.T on incoming S/G. (All required materials will be provided by contractor)- 4 No. (B) Fixing and making bus bar connections in between all switchgears after cleaning and tapping with H.T. Tape, empire tape and PVC tape properly, and plugging of all opening & holes with plastic compound complete work including cost of all material (All required materials will be provided by contractor)-1 No.& (C) Shifting carefully & installation of 33 kV single circuit transformer control panel in control room- 1 No. |
| 85 | FABRICATION, ERECTION & GROUTING OF S/s STRUCTURE:-(A) Fabrication of bus isolator& line isolater structures . Digging of two nos. pits providing stone pad at the bottom of the pit and grouting pad at the bottom of the pit and grouting of two legs of the isolator structure in CC (cement coarse sand and stone grit including supply of all civil materials complete in all respect. The work includes dragging, shifting raising and erecting the two legs with runner in proper allignment, and level and plumb. Both plinths of the isolator structure shall be properly finished with smoothening of edges- 1 No. & (B) Fabrication of Lightening Arrestor/CT structure/Post structure Digging of two Nos pits providing stone pad at the bottom of the pit and grouting of two legs of the above structures in CC (Cement, coarse sand and stone grit including supply of all civil material complete in all respect. The work includes dragging, shifting , raising and erecting the legs in proper alignment, level and plumb. Both plinths of the structures shall be properly finished with chambering of edges etc.- 3 No. |
| 86 | Grouting & concreting along with plinthing and muffing of PCC pole by providing sand, cement, grit and bricks as per norms (Sand, cement, grit and bricks will be provided by contrator) |
| 87 | Grouting of stay by providing sand, cement, grit and bricks as per norms (Sand, cement, grit and bricks will be provided by contrator) |
| 88 | Digging & Making of Pakka cable trench 650mm wide and 1250 mm deep by providing cement, sand, bricks & C.C. trench cover for laying of 11 kV 3x300 sqmm XLPE cable from both 5MVA Transformer (All required materials like cements, sands, bricks & C.C. trench cover etc will be provided by contractor) |
| 89 | Laying & dressing of 11 kV, 3*300 sqmm underground cable from 5MVA T/F to 11 kV incoming switchgear in the Pakka trench 650 mm wide, 1000 mm deep providing 150mm fine sand, cushion beneath and 150mm fine sand cushion above the cable. The cable shall be duly protected by bricks, sand & saparate stone slab. The work includes supplying of fine sand, bricks and stone slab are refilling and ramming of the left out soil, closing the trench and leveling. Spare cable shall be left and burried in the trench in the shape of rings at both ends cable laying work includes unrolling cutting mage ring and sealing both ends of the cable. (All required materials likes sand, bricks & stone slab etc. will be provided by contractor) |
| 90 | Digging & making of cable trench 650mm wide and 1250 mm deep by providing sand, bricks & saparate stone slab for each 11 kV 3x185 sqmm XLPE cable (All required materials like sands, bricks & stone slab etc will be provided by contractor) |
| 91 | Laying & dressing of 11 kV,3*185 sqmm underground cable in the trench 650 mm wide, 1000 mm deep providing 150mm fine sand, cushion beneath and 150mm fine sand cushion above the cable. The cable shall be duly protected by Ist class bricks, sand & saparate stone slab. The work includes supplying of fine sand & bricks & stone slab and refilling and ramming of the left out soil and leveling. Spare cable shall be left and buried in the trench in the shape of rings at both ends (All required materials likes sand, bricks & stone slab etc. will be provided by contractor) |
| 92 | Fixing & jointing of 11 kV,3x300 sqmm XLPE cable Outdoor jointing kit after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes, cotton tape, plumbing material and lugs etc. |
| 93 | Fixing & jointing of 11 kV,3x300 sqmm XLPE cable Indoor jointing kits on switchgears after carefully removing the insulation of the cable, duly plumbing and taping of cable providing,fixing and crimpling of proper size good quality lugs,duly plumbing and taping of cable with good Quality of cotton tape ,empire tape, HT Tape and PVC Tape, properly fixing of lugs on switchgears and boxes complete in all respect including cost of material such as insulating Tapes ,cotton Tape,Plumbing material and lugs etc |
| 94 | Fixing & jointing of 11 Kv 3x185 sqmm XLPE cable Outdoor jointing kit after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work including cost of material such as insulating tapes, cotton tape, plumbing material and lugs etc. |
| 95 | Fixing & jointing of 11 kV,3x185 sqmm XLPE cable Indoor jointing kits on switchgears after carefully removing the insulation of the cable, duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs, duly plumbing and taping of cable with good Quality of cotton tape ,empire tape, HT Tape and PVC Tape, properly fixing of lugs on switchgears and boxes complete in all respect including cost of material such as insulating Tapes ,cotton Tape, Plumbing material and lugs etc |
| 96 | Hosting of 11 kV,3*185 sqmmXLPE cable with 100 mm Dia, 3.5 mtr long GI Pipe on the outgoing feeder cable before mounting the cable on the double pole, lifting, mounting and clamping of 11 kV feeder cable boxes on the feeder double pole structure and making connection including supply of cable mounting clamps The work includes the sealing of GI Pipes lower end of the Pipe is to be buried into the earth by about one foot |
| 97 | Erection of 33/11 Kv 5MVA Power T/F including mounting of T/F on plinth in safe position, fixing of radiator, conservator tank, top up of T/F oil and commissioning of all accecassaris. |
| 98 | Painting of all structure, earthing strip, neutral strip stand & T/F cable stand, LA, ISO, CT metal parts etc. with Alluminium paint & Red Oxide Paint (All required materials like red oxide, alluminium paints will be provided by contractor) |
| 99 | Miscllaneous Work (Soil filling & Leveling, Dismental & erection of boundery wall etc.) |
| 100 | Cartage of 5MVA T/F |
| 101 | Cartage charges of all other materials Please Enable Macros to View BoQ information |