| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground |
| 2 | Demolition of Brickwork or stone masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and directed |
| 3 | Demolition of concrete (Unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) |
| 4 | Excavating in post holes (or similar holes) in soft/disintegrated each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc.50m and making good surface. |
| 5 | M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete all as directed by Engr-in-charge |
| 6 | M&L Providing precast cement of Type B0 1:2:4 (12.5mm graded aggregate) set in cement .mortar 1:4 concrete louvres and jallies,35mm thick (measured solid), including all .mouldings |
| 7 | M&L PCC (1:4:8) type D2 using 40 mm graded stone agg as in foundation filling & mass concrete. |
| 8 | M&L for Pre-cast cement concrete block(Type B1 1:2:4 20 mm graded aggregate ) masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified and directed. |
| 9 | Taking down cement plaster on brick or stone walls or ceiling surfaces etc including raking out joints hacking for key scrubbing down with water and include for all necessary lowering, etc., removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plasteringcomplete all as specified and directed. |
| 10 | M&L for rendering 15mm thick plastering in patches of area not exceeding 3 sqm in cm 1:4 on brick masonary surfaces and finished the even and fair without using extra cement including Taking down cement plaster on brick or stone walls or ceiling surfaces etc including raking out joints hacking for key scrubbing down with water and include for all necessary lowering, etc., removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plasteringcomplete all as specified and directed. |
| 11 | M&L for rendering 15mm thick in cm 1:4 on brick masonary surfaces and finished the even and fair without using extra cement |
| 12 | Supply only integral water proofing compound complete all as specified and directed. |
| 13 | M & L for providing PCC 1:2:4, type B0 using 12.5 mm graded stone aggregate in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, parapets and railing upto 60 cm in height, copings, kerbs, water troughs including weathering, slightly rounded or chamfered angles and throating includes formwork for sides,edges complete all as specified and as directed by Engr-in-Charge. |
| 14 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer ,as per manufacturer's specification. |
| 15 | M&L for preparation of new plastered surfaces of walls and applying two or more coats with 100% premium acrylic emulsion paint having VOC content less than 50 gms/litre and UV resistance as per IS 15489:2004, alkalie and fungal resistance, dirt resistance, exterior paint of required shade with silicon additives @ 1.43L/10sqm over and including priming coat of exterior primer applied at 0.9L/10sqm complete all as specified and directed by Engr-in-Charge |
| 16 | M&L for preparation of old decorated plastered or unplastered surfaces, including washing, rubbing down and stopping of distempered and painted surfaces with complete removal of existing treatment over external walls. Note : 1. Washing and Removal of existing treatment shall be carried out by mechanized means and by jet washing (90-150 bar) as required and directed by Engr-in-Charge |
| 17 | M&L for applying of two coats of cement base paint over a coat of primer to the walls complete all as specified and as directed by Engineer-in-Charge. |
| 18 | M&L for applying two or more coats on old surfaces with 100% premium acrylic emulsion paint having VOC content less than 50 gms/litre and UV resistance as per IS 15489:2004, alkalie and fungal resistance, dirt resistance, exterior paint of required shade with silicon additives @ 1.43L/10sqm over and including priming coat of exterior primer applied at 0.9L/10sqm complete all as specified and directed by Engr-in-Charge. |
| 19 | S & F rolled mild steel in Joist, channel, angle,flat iron or tee sections Fe 410-W (Gde-E- 250 quality 'A') , fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) |
| 20 | S&F mild steel nuts and bolts not exc.12 mm dia of bolt and not exc. 75mm in length with two washers,one bolt all as specified. |
| 21 | M & L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide on surfacess of any discription, over 10cm in width or girth. |
| 22 | M & L for preparation of old steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide on surfaces of any discription, over 10cm in width or girth. |
| 23 | S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured). |
| 24 | S&F in repair 4mm dia galvanised steel wire,(Chain Link PVC Coated) n.exc 50x50mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed. |
| 25 | Supply and fix mild steel round bars 10mm dia and over, cut to length, bent to shape including cranking, bending, hooping for chain link fencing etc and binding with MS wire not less than 0.9mm dua (annealed) etc complete all as secified and as directed by Engineer-in-charge. |
| 26 | Cutting of bushes/Site clearence up to 1m both sides from the fencing |
| 27 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 28 | M&L for Granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20mm thick screed bed in CM 1:4 |
| 29 | Material and labour for Granite of 20mm thick(of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including backing coat with cement mortar 1:4, 10mm thick on fair faces of brick work or concrete surfaces to receive wall tiles/ granite all as specified and directed. . |
| 30 | M&L for cement concrete type C2 1:3:6 using 40mm graded stone aggregate 75 mm thick as in base of tiles etc. |
| 31 | M&L for chequered cement concrete tiles 20cmx20cmx25mm rubber finished thick set,jointed and pointed in neat cement slurry in floors with grey cement and pigments including 20 mm thick screed bed in CM 1:6. |
| 32 | M&L for Endura Industrial tiles 10mm thick (square/rectangular) area of each tiles exceeding 0.09 sqm but not exceeding 0.18 sqm in floors etc.set and jointed in neat cement slurry and pointed in white or coloured to match incl 20mm thick screed bed in CM 1:6. |
| 33 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mmthick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. |
| 34 | M&L for brick work with fly ash bricks straight or curved on plan n exc 6m mean radius built in old size brick in CM 1:6 complete all as aspecified and directed |
| 35 | M&L for plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling, mass concrete and sub base of floor complete all as specified and directed. |
| 36 | Material and labour for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/slopped ends etc complete all as specified and directed. |
| 37 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.to be fixed in road side kerbs of size 30x45 cms of minimum thickness 10 cms complete all as specified and directed. |
| 38 | M & L PCC 1:3:6 type C-1(20mm graded aggregate), 75mm thick as in plinth protection, Surface finished fair and smooth without using extra cement. |
| 39 | Dismantling wrought iron or mild steel work for barbed wire with old chain link fencing and rolling shutters obtained from with of any description etc. |
| 40 | Material and labour for fixing of acrylic sheet of 3mm thickness design sheet for gates,doors or any other openings with screws all as specified and directed. |
| 41 | Material and labour for Framed work confirming to Fe 410 W Gde E as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 42 | M & L for reinforced cement concrete of Type B1 1:2:4 (20 mm graded aggregate) as in Foundations, including rafts, footings, foundation beams;plinth beams; bases for columns,columns,beams etc.; basement slabs,under-reamed piles and mass concrete all as specified and directed by Engg in charge. |
| 43 | Demolition of concrete (reinforced) of any description and in any position not otherwisespecifically provided for (reinforcement cut as required to facilitate demolition) |
| 44 | M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;columns and similar work; vertical or to batter all as specified and directed. |
| 45 | S&F MS TMT Bars of 10 mm dia and over,cut to length,bent to shape required including cranking, binding spirally for hooping for columns hooking ends and biniding with and including MS wire (annealed) not less than 0.9 mm dia or securining with clip complete all as aspecified and directed |
| 46 | S&F MS TMT Bars of 6 mm to 8 mm dia and over,cut to length,bent to shape required including cranking, binding spirally for hooping for columns hooking ends and biniding with and including MS wire (annealed) not less than 0.9 mm dia or securining with clip complete all as aspecified and directed by engr in charge. |
| 47 | Supplying and laying of 110mm PVC pipe single socketed in any length with rubber ring joints laid fittings on walls/ceiling or laying in floors complete all as specified. Please Enable Macros to View BoQ information |