| 1 | HSR [6.1.1]-Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 2 | HSR [6.33.1]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and costof these items shall be deemed to be included in the rates for reinforcement. 1. Mild steel and Medium Tensile steel bars |
| 3 | HSR [13.29.2] Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 4 | HSR [6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 5 | HSR [9.35]Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. |
| 6 | HSR [7.22.1]Brick work with common burnt clay nonmodular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 7 | HSR [5.15.2]Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: 2. Asbestos Cement sheet |
| 8 | LB055. Welder |
| 9 | PM074. Cranes c) 3 tonnes |
| 10 | PM026. Tractor with trolley |
| 11 | PM122. Generator 33 KVA Please Enable Macros to View BoQ information |