| 1 | Taking out existing Grill and aluminium door, window shutter, repair by cutting, painting etc. and refining of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required,all complete as per the direction of the Engineer-in- charge. | Taking out existing Grill and aluminium door, window shutter, repair by cutting, painting etc. and refining of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required,all complete as per the direction of the Engineer-in- charge. |
| 2 | Brick work with bricks of minimum crushing strength 60 kg/cm2 in superstructure above plinth level upto floor 'V' level in cement mortar 1:6 (1 Cement : 6 coarse sand). | Brick work with bricks of minimum crushing strength 60 kg/cm2 in superstructure above plinth level upto floor 'V' level in cement mortar 1:6 (1 Cement : 6 coarse sand). |
| 3 | 12mm cement plaster of mix1:4 (1 cement : 4 sand) for fair faces including cost and conveyance of all materials, labour, scaffolding etc. complete asdirected by Engineer-in-Charge at all levels | 12mm cement plaster of mix1:4 (1 cement : 4 sand) for fair faces including cost and conveyance of all materials, labour, scaffolding etc. complete asdirected by Engineer-in-Charge at all levels |
| 4 | Removing white or colour wash by scrapping andsand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | Removing white or colour wash by scrapping andsand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 5 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gm / sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x 15x 0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gm / sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x 15x 0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 6 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 7 | Providing and fixing powder coated aluminium work for windows & ventilators with extruded built up standard tubular sections/appropriate Z sections & other sections of approved make confirming to IS:733 & IS:1285 fixed withdash fasteners of required dia and size, including necessary filling up of gaps at junctions, at top, bottom & sides with required EPDM Rubber/neoprene gasket etc. Aluminium sections shall be smooth,rust free, straight, mitred & jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/panelling,CP brass/stainless steel screws all complete as per architectural drawings & directions of Engg.- in- charge(glazing, panelling & dash fasteners to be paid separately).Minimum thickness of powder coating for powder coated Aluminium shall be 50 micron : For fixed portion | Providing and fixing powder coated aluminium work for windows & ventilators with extruded built up standard tubular sections/appropriate Z sections & other sections of approved make confirming to IS:733 & IS:1285 fixed withdash fasteners of required dia and size, including necessary filling up of gaps at junctions, at top, bottom & sides with required EPDM Rubber/neoprene gasket etc. Aluminium sections shall be smooth,rust free, straight, mitred & jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/panelling,CP brass/stainless steel screws all complete as per architectural drawings & directions of Engg.- in- charge(glazing, panelling & dash fasteners to be paid separately).Minimum thickness of powder coating for powder coated Aluminium shall be 50 micron : For fixed portion |
| 8 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 9 | For shutter of doors , windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required(fittings shall be paid for separately) | For shutter of doors , windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required(fittings shall be paid for separately) |
| 10 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 11 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm |
| 12 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel/pvc conduit as required.(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel/pvc conduit as required.(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 13 | Supply and Fixing of 4 Modular Switch Boards consist 8 No's of ON/OFF Switch and 1 No's of 5/15 AMP Socket | Supply and Fixing of 4 Modular Switch Boards consist 8 No's of ON/OFF Switch and 1 No's of 5/15 AMP Socket |
| 14 | Providing and Fixing of WPC Wall Paneling with all aceesories. (Design to be selected in consultation with EIC) | Providing and Fixing of WPC Wall Paneling with all aceesories. (Design to be selected in consultation with EIC) |
| 15 | Providing and fixing of roller binds for 20 nos of window each of size (4ft wide x 6ft long)= 2.23 sqm per unit | Providing and fixing of roller binds for 20 nos of window each of size (4ft wide x 6ft long)= 2.23 sqm per unit |
| 16 | Providing and fixing of branded LED Profile light on the false ceiling. | Providing and fixing of branded LED Profile light on the false ceiling. |
| 17 | Supply and fixing of 15watt circular LD Light | Supply and fixing of 15watt circular LD Light |
| 18 | Shifting og Godrej,Table with computer instrument after complition of renovation same will be installetion in room by instruction of EIC | Shifting og Godrej,Table with computer instrument after complition of renovation same will be installetion in room by instruction of EIC |