| 1 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, taking out/alying UG cableetc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out in soft/ loose soil complete all as specified & directed. |
| 2 | Excavating in trenches. n exc 1.5 m wide and depth exc 1.5m and not exc 3m, for foundation, etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed. |
| 3 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil, complete all as specified and directed. |
| 4 | Removing excavated surplus materials (Soils) to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 5 | Supply and laying dry river sand cushioning for cable protection with a layer of 8cm deep before laying and 15cm after laying gently punned down to 10 cm on top of the cable as per SSR Part-I complete all as specified and as directed. (Note : Punned thickness shall be measured). |
| 6 | Material and Labour for bricks common burnt clay, building brick, sub class B designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed. |
| 7 | Supply, laying, jointing including testing in replacement, connecting, testing and commissioning of LT under ground cable sectional area 240Sqmm x 3.5 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed :Note : Manufacturer's test certificate shall be submitted alongwith RAR/FB to Engr-in-Charge. |
| 8 | Supply, laying, jointing including testing in replacement, connecting, testing and commissioning of LT under ground cable sectional area 120Sqmm x 3.5 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed :Note : Manufacturer's test certificate shall be submitted alongwith RAR/FB to Engr-in-Charge. |
| 9 | Supply, laying, jointing including testing in replacement, connecting, testing and commissioning of LT under ground cable sectional area 95Sqmm x 3.5 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed :Note : Manufacturer's test certificate shall be submitted alongwith RAR/FB to Engr-in-Charge. |
| 10 | Supply, laying, jointing including testing in replacement, connecting, testing and commissioning of LT under ground cable sectional area 70Sqmm x 3.5 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed :Note : Manufacturer's test certificate shall be submitted alongwith RAR/FB to Engr-in-Charge. |
| 11 | Supply, laying, jointing including testing in replacement, connecting, testing and commissioning of LT under ground cable sectional area 25Sqmm x 3.5 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed. |
| 12 | Supply, laying, jointing including testing in replacement, connecting, testing and commissioning of LT under ground cable sectional area 16Sqmm x 4.0 Core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed. |
| 13 | Material & labour for making hole by suitable means for insertion of GI pipe 80 mm bore for passing cable across the road without cutting the road complete all as specified & directed. |
| 14 | Supply fixing as in repair steel tubular swaged pole 9.00m long Type -410 SP-31 conforming to IS-2713 part I to III 1980 with and including cast iron base plate, finial taper plug,nuts, bolts and washers etc. and fixed into plain cement concrete foundation duely painted with two coats of aluminium paint over one coat of red oxide primer including preparetion of surfaces and making strip 150mm wide upto 1.50m( above PCC coping) by black, yellow paint in alternate layers and pole nos. including dismantling of old poles of any description including demolition of concrete foundation complete all as specified and directed. NOTE: Earth work, cement concrete will be measured and paid seperately. |
| 15 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete etc complete all as specified and as directed. |
| 16 | M&L for PCC 1:2:4 type B-1 using 205 mm graded aggregate as in coping of pole etc including formwork complete all as specified and as directed. |
| 17 | Material and labour for 80mm bore galvanized mild steel/ tubes, 'light grade, complete with all fittings; fixed to poles for protection of cable from junction box to street light with mild steel clamps, bolts, nuts and washers as required for pipe for fixation of pipe alongwith pole complete all as specified and as directed. |
| 18 | Material and labour for timer switch, 250 volt, single phase, 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed. |
| 19 | Supply and fixing in repair PVC insulated and PVC round sheathed, copper conductor industrial cable 2.5Sqmm, three core of copper conductor for connection of street light/ flood light/ posttop lantern/ garden light etc fittings on pole/wall/ pillar from over head conductor/ junction box/ DB including termination clip etc complete in all respect including through GI pipe of size 15/20mm dia complete all as specified and as directed. |
| 20 | Supply and fixing as in repair LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 21 | Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 22 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including connecting up with three core flexible copper conductor cable of 2.5Sqmm complete all as specified and as directed. |
| 23 | Supply and fixing House service bracket complete with 1.5m long G.I. pipe 40mm dia light. grade, two nos 90/45 degree bends, M.S.hook and stay or guy and fixed with 25mm x 4mm MS flat with necessary nuts, bolts, washers etc, as required and painting with two coats of synthetic enamel paint over a coat of primer and fixed to pole complete all as specified & as directed. |
| 24 | Supply and fixing in replacement Cable Junction Boxes IP 66 “halogen free and weather proof” for outdoor installation (with metric knockouts for cable entry - Black Colour) size 205 x 255 x 112 mm suitable for 16/25 sq.mm fixed to pole /wall with suitable FI clamp 20X3 mm nuts , bolts and washers including provision of 01 No miniature circuit breaker (MCBs) single pole, 240 volts 10 KA 6 Amps and including suitable capacity aluminium bus bar (minimum 100Amps-04Nos) mounted on insulator complete all as specified and as directed. |
| 25 | Supply, installation, testing and commissioning of LT Panel board, TPN 415 Volts, 50 Hz, out door cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley aluminium bus bar suitable for carrying of current 400 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.50 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- |
| 26 | (a) MCCB 250 Amps 4 Pole 50 Hz 415 V with thermal magnectic& adjustable Magnetic type capacity 36 KA - 1Nos (Incoming). (b) MCCB 160 Amps 4 pole, 50 Hz, 415 Volt with adjustable thermal & Fixed magnetic type, 36 KA - 01 Nos (Outgoing).(c) MCB DP, 32 Amp, 2 pole, 50 Hz, 240 Volt, 36 KA - 03 Nos (Outgoing).(d) MCB, 63Amp, 4 pole, 50Hz, 240 Volt- 02 Nos (Outgoing)(e) 3Ph digital multi function meter model A, class 1, 5A with relay Vega Series - 1Nos(f) Indicating lamp 240 volts LED type - set of three. |
| 27 | Supply, installation, testing and commissioning of LT Panel board, TPN 415 Volts, 50 Hz, out door cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley aluminium bus bar suitable for carrying of current 400 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.50 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- |
| 28 | (a) MCCB 400 Amps 4 Pole 50 Hz 415 V with thermal magnectic& adjustable Magnetic type capacity 36 KA - 1Nos (Incoming). (b) MCB 250 Amps 4 pole, 50 Hz, 415 Volt ith adjustable thermal & Fixed magnetic type, 36 KA - 01 Nos (Outgoing).(c) MCB 160 Amps 4 pole, 50 Hz, 415 Volt ith adjustable thermal & Fixed magnetic type, 36 KA - 02 Nos (Outgoing).(d) 3Ph digital multi function meter model A, class 1, 5A with relay Vega Series - 1Nos(e) Indicating lamp 240 volts LED type - set of three. |
| 29 | Supply, installation, testing and commissioning of LT Panel board, TPN 415 Volts, 50 Hz, out door cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley aluminium bus bar suitable for carrying of current 400 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.50 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following :- |
| 30 | (a) MCCB 200 Amps 4 Pole 50 Hz 415 V with thermal magnectic& adjustable Magnetic type capacity 36 KA - 1Nos (Incoming). (b) MCB 125 Amps 4 pole, 50 Hz, 415 Volt ith adjustable thermal & Fixed magnetic type, 36 KA - 03 Nos (Outgoing).(c) MCB SPN, C curve, 63Amp - 04 Nos (Outgoing).(d) 3Ph digital multi function meter model A, class 1, 5A with relay Vega Series - 1Nos(e) Indicating lamp 240 volts LED type - set of three. |
| 31 | Material and labour for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SI Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work, PCC pit with RCC cover, char coal, salt, funnel etc including taking down old earthing complete all as specified and as directed. Note:- Rate quoted by tenderers shall be deemed to include for following provisions-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 m. [ii].PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore medium grade & copper lugs, charcoal & salt as reqd .[v]. GI protection pipe of size 15 mm bore light grade 7.5m. |
| 32 | Supplying, installing, commissioning and tasting in repair factory made outdoor type LT Kiosk box with canopy of size 1000mmx600mmx450mm made out of 3.15mm thick CRCA sheet duly powder coated with 4 nos 300 Amps copper busbar and 4 nos Mild steel legs of size 40mmx40mmx5mm of length 1000 mm and locking arrangement with one Nos of MCCB of 160 Amp 4 pole 36 KA as incomming including grouting in PCC 1:3:6 type C-1 complete all as specified and directed. |
| 33 | Material and labour for 110mm outer dia 3-layer PP-R Polypropylene random co polymer pipes SDR 7.4 & PN16 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches/ floor on walls/ under the road or hardstanding and proper saddle on wall at places where directed including taking out old pipes of any description complete all as specified and as directed. |
| 34 | Material and labour for 63mm outer dia 3-layer PP-R Polypropylene random co polymer pipes SDR 7.4 & PN16 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches/ floor on walls/ under the road or hardstanding and proper saddle on wall at places where directed including taking out old pipes of any description complete all as specified and as directed. |
| 35 | Material and labour for 32mm outer dia 3-layer PP-R Polypropylene random co polymer pipes SDR 7.4 & PN16 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches/ floor on walls/ under the road or hardstanding and proper saddle on wall at places where directed including taking out old pipes of any description complete all as specified and as directed. |
| 36 | Material & labour for Steel water tubing 20mm bore, galvanised iron, medium grade, ISI Marked, laid in trench and the like with all fittings such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps plugs and unions etc., including taking down old pipe in any position, complete all as specified. |
| 37 | S&F in repair 20mm Gun-metal, globe or gate valves, cast copper alloy screwd down high pressure with clutch handle screwed both ends for iron pipe including all fittings and fixed complete all as specified and as directed. |
| 38 | S&F in repair 25mm Ball brass valves. high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 39 | S&F in repair 20mm Ball brass valves. high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 40 | Supply and fixing in repair 100 mm bore cast iron flanged type sluice valve, (ISI marked), conforming to IS 14846-2000; Class PN-1.6 with stainless steel spindle and brass check nut (non raising spindle type) including all jointing materials and mild steel nuts, bolts, washers, rubber / fibre board gaskets (neouprene) etc and testing complete all as specified and directed.. |
| 41 | M&L for construction of brick masonry valve pit of size 120x120x120cm (internal dimension) one brick thick wall built in CM (1:4) on 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4) both externally and internally, external plaster shall be up to 25cm below GL, providing valve pit cover made of 1.60mm thick MS sheet/plate, including provision of hinges, handle and locking arrangement including 40X40X3mm angle iron frame fixed on top of valve pit by means of MS hold fast 40x5mm and 150mm long, embedded in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) and wall of sub class 'B' bricks, including two coats of anti-corrosive paint over a coat of red oxide zinc Chrome primer and necessary earth work in soft/loose soil complete all as specified & directed. Please Enable Macros to View BoQ information |