| 1 | Demolition of brick work /stone masonry/PCC block masonry built in cement mortar of any description all as specified and directed. |
| 2 | Taking down cement plaster of any description hacking for key or raking out joint on old brick work/ stone /concrete surface etc complete all as specified and as directed |
| 3 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not specifically provided for complete all as specified and as directed |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and as directed |
| 5 | Dismantling of Fencing posts or struts (wood, steel RCC) any section, posts embeded in natural ground etc, including taking out embeded portion and making good distrubed ground complete all as specified and as directed |
| 6 | Dismantling of fencing wire mesh, any type etc complete all as specified and as directed |
| 7 | Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed. |
| 8 | Demolition of Stone slab and tiles incl backing coat of any description or thickness in floors, aprons etc (Laid dry or laid dry and pointed) etc complete all as specified and as directed |
| 9 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise etc complete all as specified and as directed |
| 10 | Demolition and breaking up drain pipes up to 110 mm dia bore (PVC Pipes) set in cement mortar etc complete all as specified and as directed |
| 11 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Soft / Loose etc complete all as specified and as directed |
| 12 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. etc complete all as specified and as directed |
| 13 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed et complete all as specified and as directed |
| 14 | Excavating in post holes(or similar holes) each n exc .5 cum getting out in Hard / Dense soil soil,returning, filling in and ramming earth in layers n exc 25 cm etc complete all as specified and as directed |
| 15 | Material and labour for Hardcore of gauge n exc. 63 mm of broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc all as specified and as directed |
| 16 | Material and labour for Sand filling under floors or in foundations including watering and consolidation under bedding for interlocking tiles etc complete all as specified and as directed |
| 17 | Material and labour for plain cement concrete Type D-2 1:4:8 (with using 40 mm graded stone aggregates) as in foundations and mass concrete etc complete all as specified and as directed |
| 18 | Material and labour providing cement concrete type B 0 1:2:4 (using 12.50mm graded stone aggregate) in copings, leveling concrete, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed |
| 19 | Material and labour for plain cement concrete 1:2:4 type B-1, (with using 20 mm grades stone aggregates) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and base) incl form work etc complete all as specified and as directed |
| 20 | Material and labour for Providing 25mm thick precast cement concrete louvres Type B-0 , 1:2:4 (with using 12.5 mm graded stone aggregaes) set in CM 1:6 as and jallies, 25mm thick (measured solid), including all mouldings but excluding frame (Pre -cast frame shall be measured separately and paid for under item) etc complete all as specified and as directed |
| 21 | Material and labour for Reinforced cement concrete (nominal mix) type B-1 (1:2:4) with using 20 mm graded stone aggregates as Columns, pillars, piers, posts, ftg, etc struts etc complete all as specified and as directed |
| 22 | Material and labour Brickwork (Old size Brick) with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 etc complete all as specified and as directed |
| 23 | All as per item No 22 above, but except brick. |
| 24 | Material and labour Brickwork (Old size Brick)with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 etc complete all as specified and as directed |
| 25 | All as per item No 24 above, but except brick |
| 26 | Material and labour for 18 to 20mm thick granite Granite stone slab (of any type) work (table rubbed and polished) Granite (of any type) work for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab including grinding the edges half round etc complete all as specified and as directed |
| 27 | Material and labour for formwork with square / rectangular pillars, posts, struts, piers, columns and, ftg etc, stanchions with rough finished surface of concrete etc complete all as specified and as directed |
| 28 | Material and labour TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete. |
| 29 | All as per item No 28 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and as directed |
| 30 | Supply and fix framed work such as grills, gratings, guard bars etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 incl dismantling of existing Mild steel work work etc complete all as specified and directed. |
| 31 | Supply and fix posts and struts as in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 etc complete all as specified and as directed |
| 32 | Supply and fix mild steel screw bolts (machine made) with hexagonal or spuare heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square not n.exc 5 cm long and diameter of shank 5 to 10 mm complete all as directed |
| 33 | Supply only galvanised chain link fencing of mesh size (75mmX75mmX3.15mm) etc complete all as specified and as dicected |
| 34 | Fixing only galvanised chain link fencing of mesh size (75mmX75mmX3.15mm)) size and any type of standards, rails, straining bolts, etc. including provission of binding wire etc complete all as specified and as directed |
| 35 | Supply and fix PVC coated chain link fencing, size of mesh 75 mmx 75 mm made out of 3.15mm dia GI wire (conforming to relevant IS) excluding thickness of PVC coated , colour as approved, fixed to any type of fencing pots, standard rails, straining bolts etc complete all as specified and directed . |
| 36 | Supply only Mild Steel TMT round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and as directed |
| 37 | Supply and fix in repair galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and orovising of galvanised mild steel wire, staples or steel pins, etc. complete all as directed. (each line wire measured) |
| 38 | Supply and fix in repairs barbed razor type concertina coil of 610 mm dia (when unstretched) fixed between the existing ‘V’ angle post and barbed wire over security wall /PCC /ground as per requirment with coil of coverage 6.00 running metre per coil, weight of each coil 9.50 to 10.00 Kg hot dip galvanized and binding with and including MS annealed wire of 0.90 mm , complete all as specified and directed . |
| 39 | Restraining and resecuring existing barbed wire of any description including making good stapples etc complete all as specified and directed |
| 40 | Material and labour for rubber Moulded Factory made Pre-cast Kerb stones of cement concrete Type B-1 1:2:4 (with using 20mm graded stone aggregates) fixed in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required et complete all as specifed and as directed. |
| 41 | Material and labour for 75 mm thick cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base of flooing etc complete all as specified and as directed |
| 42 | Material and labour for machine presssd Pre-Cast concrete interlocking coloured paving Block of glass fibre reinfoced glossy finished vibro compacted any shape and size confirming to IS-15658-2006 of 60 mm thick, M-35 grade to match with grey cement and pigment etc complete all as specified and as directed |
| 43 | Material and labour for machine presssd Pre-Cast concrete interlocking coloured paving Block of glass fibre reinfoced glossy finished vibro compacted any shape and size confirming to IS-15658-2006 of 80 mm thick, M-35 grade to match with grey cement and pigment etc complete all as specified and as directed |
| 44 | Supply and fix for exterior grade, coloured glossy finish rubber pressed, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles over etc complete all as specified and directed. |
| 45 | Material and labour for Heavy duty parking tiles (Coloured) 8 to 9 mm thick area of each tiles exceeding 0.18 sqm but not exceeding 0.36 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and as directed |
| 46 | Material and labour for Screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes etc complete all as specified and as directed |
| 47 | Material and labour for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed |
| 48 | Material and labour for Preparation of new plastered surface of wall and applying two coat of cement base paint etc complete all as specified and as directed |
| 49 | Material and labour for comple removal of existing treatment of Old plastered surface of wall and applying two coat of cement base paint etc complete all as specified and as directed |
| 50 | Material and labour for preparing new concrete surface (Kerb Stone) and applying two coat of synthetic enamel paint over a coat of primer etc complete all as specified and as directed |
| 51 | Material and labour for preparing Old concrete surface (Kerb Stone) and applying one coat of synthetic enamel paint etc complete all as specified and as directed |
| 52 | Material and labour for Preparation New of previously un treated steel and iron surface of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed |
| 53 | Material and labour for 110 mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified and as directed Please Enable Macros to View BoQ information |