| 1 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surace/recessed conduit/submain wiring/cable as required. |
| 2 | Supplying and embedding following dia G.I. pipe(medium class) in pole collar/foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. |
| 3 | 40 mm dia |
| 4 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 5 | 2 x 16 sq mm(22 mm) |
| 6 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc complete as required. |
| 7 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 8 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K /5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (i) 50 Watt |
| 9 | Supplying and drawing 3 core x 1.5 sq. mm size FRLS PVC sheathed and insulated multi stranded copper conductor in the existing GI octogonal pole for making connection from SP MCB to LED street light fitting including testing etc as required. |
| 10 | Providing & fixing and erection of hot dip galvanized GI octogonal pole of length 5 mtr top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimensions 200 x 200 x 12 mm PCD 200 mm with 04 Nos foundation bolts of 450 mm length 16 mm dia with single arm standard bracket of 0.5 mtr length on the foundation made of cement concrete base 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 40 mm nominal size)including excavation and refilling etc as req as per direction of Engg-in-Charge. |
| 11 | Supplying & fixing SMC junction box of minimum size (HxWxD) 140x140 x95 mm in the existing street light pole including 6 Amp MCB, 2 way connector and clamp with nut and bolts etc as req. |
| 12 | Supplying and laying of one number XLPE power cable of 1.1 KV grade of 2 x 16 Sqmm size in the existing DWC HDPE/ METAL pipe/open as required. Please Enable Macros to View BoQ information |