| 1 | Full stator rewinding of ceiling fan (condenser type) of 1400 mm sweep with new copper winding wires including cleaning and insulating the stator slots, sleeving, soldering, wrapping of cotton tape, reassembling, varnishing and testing etc. complete. |
| 2 | Full stator rewinding of ceiling fan (condenser type) of 1200 mm sweep with new copper winding wires including cleaning and insulating the stator slots, sleeving, soldering, wrapping of cotton tape, reassembling, varnishing and testing etc. complete. |
| 3 | Providing split pin, check nuts, hanger nuts and bolts etc. including hanger if required to be replaced after removing the old. The rates includes re-erection of ceiling fan after repair and other petty material such a screws pin, bolts nuts etc. as per requirement at site. |
| 4 | Fabrication of shaft after removing the shaft from the stator body safely and then labour works for welding and turning of the same to give the original shape from workshop and other petty material required. to complete the job to the entire satisfaction of Engineer-in-charge. |
| 5 | Replacement of ball bearing of ceiling fan including greasing, re-assembling and testing etc. |
| 6 | Supply and erection of fan condenser (paper condenser) for ceiling fan of following rating: The condenser is to be installed in existing ceiling fan after dismantling the defective condenser including connection and testing etc. The fan condenser should be of Epcos make. |
| 7 | Condenser 2.5 µ fd. |
| 8 | Condenser 3.15 µ fd. |
| 9 | Condenser 4 µ fd. |
| 10 | Full stator rewinding of Exhaust fan (condenser type) of 900/ 1400 RPM with new copper winding wires including cleaning and insulating the stator slots, sleeving soldering wrapping of cotton tape, varnishing re-assembling and testing etc. complete. |
| 11 | 12\\" Sweep |
| 12 | 15\\" Sweep |
| 13 | 18\\" Sweep |
| 14 | Supply and erection of rubber reel after dismantling the defective real including connection and testing etc. |
| 15 | S/E of ceiling fan/ exhaust fan aluminum Blades set of matching colour of existing ceiling fan/exhaust fan. The job includes the cost of fixing of new blades at site after dismantling the existing blades. |
| 16 | Full stator copper rewinding of Air Circulator fan 600 mm sweep with new copper winding wires including cleaning & insulating the stator slots, sleeving, soldering, wrapping of cotton tape, varnishing, re-assembling, testing etc. The job includes the cost of all the petty material require to complete the job to the entire satisfaction of Engineer in-charge. |
| 17 | Painting of existing street light MS poles of following height/ length at site. The painting job should be done after preparation of surface with the application of sand paper etc and then the pole should be painted with aluminium paint of superior quality in two coats after applying one coat of primer. The job including for all type of labour, material, paint, ladder/ Hydraulic Crane with bucket and T&P as required at site to complete the job. The primer and paint should be of Asian Paint/ Nerolac/ Berger/ Akzo Nobel make only. |
| 18 | Street light MS pole 4.5 mtr./ 5 mtr. Long |
| 19 | Street light MS pole 7 mtr./ 7.5 mtr. / 8 mtr./ 9 mtr. Long |
| 20 | Painting of cement collar of street light poles with two coats of snowcem and MS junction box with superior quality of paint to give good look. The work should be carried out after the removal of original defective paint from the cantilever/ MS junction box with the help of sand paper etc. The RCC collar surface should be properly cleaned and a smooth surface should be repaired and then 2 coats of superior quality snowsem paint will be done. This also includes necessary repair to the broken cement collar with cement sand mixture. The snowcem/paint should be of Asian/ JK/ Birla/ Nerolac/ Berger make only. |
| 21 | Spray Painting of steel shutter/ outdoor type pedestal etc. The rusted steel shutter/ other cover of pedestal etc. shall be given anti rust/ anti grease treatment and then spray painted with one coat of primer and 2 coats of superior quality of red/grey paint as approved by EIC of work. The primer and paint should be of Asian Paint/ Nerolac/ Berger/ Akzo Nobel make only. |
| 22 | DSR item No.1.59 Dismantling of ceiling fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins, reinstalling the same as required. Please Enable Macros to View BoQ information |