| 1 | Excavation in trenches, not execeeding 1.5m wide and not exceeding 1.5m deep for foundation, laying of pipes etc., or for shafts, wells, cesspits , manholes etc., n.exc 10 sqm on plan and n.exceeding 1.5 m depth and getting out in soft/ loose soil, etc. complete all as specified and as directed. |
| 2 | Excavation in trenches, execeeding 1.5m wide and not exceeding 3.0 m deep for foundation, laying of pipes etc., or for shafts, wells, cesspits , manholes etc., n.exc 10 sqm on plan and exceeding 1.5 m and n.exceeding 3.0 m in depth and getting out in hard/ dense soil, etc. complete all as specified and as directed. |
| 3 | Returning, filling in soil, including spreading leveling, watering and well ramming in laying not exceeding 25 cm thick, etc. complete all as specified and as directed. |
| 4 | Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exe 1.5 m above the starting point, etc. complete all as specified and as directed. |
| 5 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition, etc. complete all as specified and as directed. |
| 6 | M&L Precast RCC (1:2:4) type B1 (using 20 mm graded crushed stone aggreagate) as in cover slabs set in cement mortar (1:4) including all necessary form work and finishing exposed surfaces of concrete even and smooth with out using extra cement, etc. complete all as specified and as directed. |
| 7 | M&L for Mild steel deformed TMT bars 10 mm dia and above as in reinforcement to concrete cut to length bent to shape required including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9mm dia, etc. complete all as specified and as directed. |
| 8 | Demoliton of cement concrete (unreinforced) at any position any description not otherwise specifically provided for, etc. complete all as specified and as directed. |
| 9 | M&L Plain cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in benching of manholes including necessary formwork, weathering, slightly rounded or chamfered angles, finishing of exposed surfaces of concrete to even and smooth without using extra cement, etc. complete all as specified and as directed. |
| 10 | M&L Plain cement concrete (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in coping including necessary formwork, weathering, slightly rounded or chamfered angles, finishing of exposed surfaces of concrete to even and smooth without using extra cement, etc. complete all as specified and as directed. |
| 11 | M&L for 50 mm thick cement concrete (1:3:6) type C-2 (using 40 mm graded crushed crushed stone aggregate) as in floor/ plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges, etc. complete all as specified and as directed. |
| 12 | M&L for 75mm thick PCC (1:4:8) type D-2, (using 40mm graded crushed stone aggregate) as in Sub-base, etc. complete all as specified and as directed. |
| 13 | M&L for plain cement concrete (1:4:8) mix, type D2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete, etc. complete all as specified and as directed. |
| 14 | M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed crushed stone aggregate) as in surface channels, drains including all necessary form work, etc. complete all as specified and as directed. |
| 15 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds,mitred/stopped ends etc. complete all as specified and as directed. |
| 16 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc. complete all as specified and as directed. |
| 17 | M&L for brick work with sub class 'B' old size bricks, straight or curved on plan exc. 6m mean radius built in cement mortar (1:4), etc. complete all as specified and as directed. |
| 18 | Demolition of precast concrete articles and precast concrete block walling, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and as directed. |
| 19 | M&L precast cement concrete (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) block masonry with machine pressed solid blocks, exc 10 cm in width setting in cement mortar (1:6), etc. complete all as specified and as directed. |
| 20 | Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. |
| 21 | M&L for rendering 10 mm thick in cement mortar (1:4) on fair faces of brickwork or concrete surfaces, finished even and smooth without using extra cement with and including integral water proofing compound @ 2 % by weight of cement in the mortar all as per manufacturer's instructions etc. complete all as specified and as directed. (Note :-WPC shall be measured and paid separately). |
| 22 | Supply only integral water proofing compound, etc. complete all as specified and as directed. |
| 23 | Dismantling of old PVC (SWR), AC, SWG soil waste and vent pipe up to 150mm dia including accessories set in cement mortar and removing rubbish from site, and taking out of trenches if required etc. complete all as specified and as directed. |
| 24 | S&F PVC (SWR) pipes 75 mm bore single socket in any length with rubber ring joints fixed to wall or laid in floors, etc. complete all as specified and as directed. |
| 25 | S&F PVC (SWR) pipes 110 mm bore single socket in any length with rubber ring joints fixed to wall or laid in floors, etc. complete all as specified and as directed. |
| 26 | S&F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for 75/110mm bore pipe including bolts and nuts and securing ends of stays to wall etc. complete all as specified and as directed. |
| 27 | S&F 75mm bore PVC (SWR) bends of any radius fitted with access door including jointing with solvent cement etc. complete all as specified and as directed. |
| 28 | S&F 110mm bore PVC (SWR) bends of any radius fitted with access door including jointing with solvent cement etc. complete all as specified and as directed. |
| 29 | S&F 75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal fitted with access door including jointing with solvent cement etc. complete all as specified and as directed. |
| 30 | S&F 110Mm bore PVC (SWR) branch piece, single (single Y) equal or unequal fitted with access door PVC (SWR) junction single, (Single T) equal or unequal including jointing with solvent cement etc. complete all as specified and as directed. |
| 31 | S&F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal fitted with access door including jointing with solvent cement etc. complete all as specified and as directed. |
| 32 | S&F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal fitted with access door including jointing with solvent cement etc. complete all as specified and as directed. |
| 33 | S&F 75 mm bore PVC (SWR) couplers jointing with solvent cement etc. complete all as specified and as directed. |
| 34 | S&F 110 mm bore PVC (SWR) couplers jointing with solvent cement etc. complete all as specified and as directed. |
| 35 | S&F 75x100mm bore PVC (SWR) reducer jointing with solvent cement etc. complete all as specified and as directed. |
| 36 | S&F 110mm bore PVC (SWR) vent cowl jointing with solvent cement etc. complete all as specified and as directed. |
| 37 | M&L in repairs PVC (SWR) floor trap 75/110 mm dia plain with grating including jointing with solvent cement and making good the disturbed portions of floor matching with adjoining surfaces, etc. complete all as specified and as directed. |
| 38 | S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of pattern \\"ORRISA\\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe including trap set in and including necessary lean cement concrete, etc. complete all as specified and as directed. |
| 39 | S&F in repairs Vitreous china wash down water closed pan (Pedestal pattern), white (excluding flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc with necessary lean cement concrete including plastic water closet seat cover of closed pattern with flat bottom and mild steel chromium plated or aluminium hinging device etc. complete all as specified and as directed. |
| 40 | S&F in repairs PVC low level flushing cistern of 10 Ltr capacity, valveless syphonic action type complete white with inlet, ball valve, float and handle including brackets etc, and making good the floors/walls as per existing floor finish/wall finish and jointing with water closet of any type etc. complete all as specified and as directed. |
| 41 | S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers, etc. complete all as specified and as directed. |
| 42 | Demolition of old PVC (SWR), AC, SWG soil waste and vent pipe up to 200mm dia including accessories set in cement mortar and removing rubbish from site, and taking out of trenches if required etc. complete all as specified and as directed. |
| 43 | M&L for plain cement concrete bed (1:3:6), type C2 (using 40 mm graded crushed stone aggregate) to drain pipe 100/110 mm bore including packing under and hunching against the sides of pipes after they laid and tested, etc. complete all as specified and as directed. |
| 44 | M&L for plain cement concrete bed (1:3:6), type C2 (using 40 mm graded crushed stone aggregate) to drain pipe 150/160 mm bore including packing under and hunching against the sides of pipes after they laid and tested, etc. complete all as specified and as directed. |
| 45 | S&F 110mm bore PVC (SWR) pipes of single socket in any length with rubber ring joints laid in trenches, etc. complete all as specified and as directed. |
| 46 | S&F 160mm bore PVC (SWR) pipes of single socket in any length with rubber ring joints laid in trenches, etc. complete all as specified and as directed. |
| 47 | M&L Cutting into the existing manhole for connecting new drain making good to pipes of 110 mm dia & rendering cutting out existing benching for and forming branch channel (½ round or ¾ section ) in cement concrete (1:2:4), Type B1 smooth finished and reforming benching as required, etc. complete all as specified and as directed. |
| 48 | M&L Cutting into the existing manhole for connecting new drain making good to pipes of 160 mm dia & rendering cutting out existing benching for and forming branch channel (½ round or ¾ section ) in cement concrete (1:2:4), Type B1 smooth finished and reforming benching as required, etc. complete all as specified and as directed. |
| 49 | Comprehenshive maintenance and cleaning blockage of sewage system including sewage lines, manholes, soakage wells/soak-pits, gully traps, septic tanks, attending bloakages in EWCs/IWCs/ WHBs/sinks/traps etc by deploying necessary resources/ manpower(Min 04 Members) including T&P (manually/ mechanically /vaccume/ pressure jet, rodding or pumping, etc ) for One month as directed by Engineer-in-charge at Kalimpong Mil Stn under GE 867 EWS, etc. complete all as specified and as directed. |
| 50 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15cm thickness (below or above ground level), etc. complete all as specified and as directed. |
| 51 | M&L for 75mm thick PCC (1:4:8) type D-2, (using 40mm graded crushed stone aggregate) as in Sub-base, etc. complete all as specified and as directed. |
| 52 | S&F for coloured glazed type pre-polished chequered cement concrete tiles 30 cm x 30 x 25 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors including 15mm thick screed bed in CM 1:6 etc. complete all as specified and as directed. |
| 53 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 54 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |