| 1 | Taking up or down the following size steel galvanized water tubing with all necessary fittings complete from walls / floor or trenches all as directed. |
| 2 | All as per items no 1 here in before but size of water pipe 40/50mm dia. |
| 3 | All as per items no 1 here in before but size of water pipe 25mm dia. |
| 4 | All as per items no 1 here in before but size of water pipe 20 mm dia. |
| 5 | All as per items no 1 here in before but size of water pipe 15 mm dia. |
| 6 | All as per items no 1 here in before but size of water pipe 80 mm dia. |
| 7 | All as per items no 1 here in before but size of water pipe 100 mm dia. |
| 8 | Cleaning,washing,descalling the following sizes serviceable GI pipe 40/50 mm dia.Refixing/re-laying in same including necessary fitting/ fixture in same tranches or new location all as directed |
| 9 | All as per items no 02 here in before but size of water pipe 25mm dia. |
| 10 | All as per items no 02 here in before but size of water pipe 20 mm dia. |
| 11 | All as per items no 02 here in before but size of water pipe 15 mm dia. |
| 12 | All as per items no 02 here in before but size of water pipe 80 mm dia. |
| 13 | All as per items no 02 here in before but size of water pipe 100 mm dia. |
| 14 | Supply & fixing of GI steel tubings 15 mm dia. of medium grade with all fittings and fixed complete to walls/ ceiling or laid in floors all as directed. |
| 15 | All as per items no-3 here in before but size of water pipe 20mm dia. |
| 16 | All as per items no-3 here in before but size of water pipe 25 mm dia. |
| 17 | All as per items no-3 here in before but size of water pipe 40 mm dia. |
| 18 | All as per items no-3 here in before but size of water pipe 50 mm dia. |
| 19 | All as per items no-3 here in before but size of water pipe 80 mm dia. |
| 20 | M&L for cutting existing steel tubing for alterations or additions of pipes size 20mm bore all as directed |
| 21 | M&L for cutting existing steel tubing for alterations or additions of pipes size 25 mm bore all as directed |
| 22 | M&L for cutting existing steel tubing for alterations or additions of pipes size 40/50 mm bore all as directed |
| 23 | M&L for cutting existing steel tubing for alterations or additions of pipes size 80/100 mm bore all as directed |
| 24 | M&L for Screwing existing steel tubing for alterations or additions of pipes size 20mm bore all as directed |
| 25 | M&L for Screwing existing steel tubing for alterations or additions of pipes size 25 mm bore all as directed |
| 26 | M&L for Screwing existing steel tubing for alterations or additions of pipes size 40/50 mm bore all as directed |
| 27 | Supply and fixing in repair the Gate valve 15mm dia made with. Gun-metal,, with iron wheel head, screwed both ends on G.I pipes with GI union, all as per directed.. |
| 28 | All as per items no-11 here in before but size of water pipe 20mm dia all as directed. |
| 29 | All as per items no-11 here in before but size of water pipe 25 mm dia all as directed.. |
| 30 | All as per items no-11 here in before but size of water pipe 40 mm dia all as directed.. |
| 31 | All as per items no-11 here in before but size of water pipe 50 mm dia all as directed.. |
| 32 | Taking up of Existing cast iron water mains pipe 80 mm dia (including all fittings)/DI Pipe,with spigot and socket end sand lead joints including burning out joints and recovering lead..Note: Earthwork will be measured and paid separately |
| 33 | All as per items no-12 here in before but size of water pipe 100 mm dia all as directed.. |
| 34 | All as per items no-12 here in before but size of water pipe 150 mm dia all as directed.. |
| 35 | All as per items no-12 here in before but size of water pipe 200 mm dia all as directed.. |
| 36 | Cleaning,washing,descalling & Refixing of Cast iron pipe 80 mm dia with spigot and socket ends s centrifugally cast. Class LA,in any length,laid in trenches.Note:- cost of jointing and jointing material will be paid separately. |
| 37 | All as per items no-13 here in before but size of water pipe 100 mm dia all as directed.. |
| 38 | All as per items no-13 here in before but size of water pipe 150 mm dia all as directed.. |
| 39 | All as per items no-13 here in before but size of water pipe 200 mm dia all as directed.. |
| 40 | All as per items no-13 here in before but size of water pipe 250 mm dia all as directed.. |
| 41 | All as per items no-13 here in before but size of water pipe 300 mm dia all as directed.. |
| 42 | Supply laying connect and testing water pipe 100 mm dia DI-K7class in repair with push to lock rubber tighten lock centrifugally in any lengths conforming to IS including DI fittings & lead joints laid in trenches/ on wall/ on floor at locations all as specified & directed. Make : Electrosteel/ TISCO/ KESORAM Make: Jindal / Electro steel casting Ltd / Kalinga. Note: Old retrive pipe to be deposited to MES store yard. |
| 43 | All as per items no-14 here in before but size of water pipe 150 mm dia all as directed.. |
| 44 | All as per items no-14 here in before but size of water pipe 200 mm dia all as directed.. |
| 45 | Taking up unserviceable CI/DI fittings up to 150 mm dia pipe and supply and fixing any type radius and angle taper any type (Straight) bend increasing decreasing or double socket etc Tee pieces, single branch ‘Y’ junction double branch, coller, capacity and plugs up to 150mm dia pipe bore CI pipe conforming to IS-1538- 1993 complete and all as specified. |
| 46 | All as per item no-15 here in before but up to 200 mm to 300 mm dia pipe all asdirected |
| 47 | Material and labour for run lead joint for 300 mm dia pipe to complete and all as specified all asdirected. |
| 48 | All as per item no-16 here in before but up to 250 mm dia pipe all asdirected |
| 49 | All as per item no-16 here in before but up to 200 mm dia pipe all asdirected |
| 50 | All as per item no-16 here in before but up to 150 mm dia pipe all asdirected |
| 51 | All as per item no-16 here in before but up to 100 mm dia pipe all asdirected |
| 52 | All as per item no-16 here in before but up to 80 mm dia pipe all asdirected |
| 53 | Supply and fixing (in repair ) mechanical joint 40 mm dia pipe made out of MS sheet fabricated as per existing site requirement including long MS nuts bolts rubber gasket cutting of pipe of any size GI/CI/MS/AC pipe all as directed . (Note:- Excavation and returning filling included in quoted rate ) |
| 54 | All as per item no-17 here in before but up to 50 mm dia pipe all asdirected |
| 55 | All as per item no-17 here in before but up to 80 mm dia pipe all asdirected |
| 56 | All as per item no-17 here in before but up to 100 mm dia pipe all asdirected |
| 57 | All as per item no-17 here in before but up to 150 mm dia pipe all asdirected |
| 58 | All as per item no-17 here in before but up to 200 mm dia pipe all asdirected |
| 59 | All as per item no-17 here in before but up to 250 mm dia pipe all asdirected |
| 60 | All as per item no-17 here in before but up to 300 mm dia pipe all asdirected |
| 61 | Taking out unserviceable sluice valves of size 100 mm dia ,refacing regrinding replacement unserviceable parts and refixing in original position all as directed.(Spare sprts for repair sluice valve will be mearsed and paid seperately in respective items) |
| 62 | Taking out unserviceable sluice valves of size 150 mm dia ,refacing regrinding replacement unserviceable parts and refixing in original position all as directed.(Spare sprts for repair sluice valve will be mearsed and paid seperately in respective items) |
| 63 | All as item no-18 here in before but size of sluice valve 200 mm dia all as directed. |
| 64 | All as item no-18 here in before but size of sluice valve 250 mm dia all as directed. |
| 65 | All as item no-18 here in before but size of sluice valve 300 mm dia all as directed. |
| 66 | Supply and fixing Steel spindle suitable for 100 mm dia suitable to match the existing sluice valve all as directed. |
| 67 | Supply and fixing Steel spindle suitable for 150 mm dia suitable to match the existing sluice valve all as directed. |
| 68 | Supply and fixing Steel spindle suitable for 200 mm dia suitable to match the existing sluice valve all as directed. |
| 69 | Supply and fixing Steel spindle suitable for 250 mm dia suitable to match the existing sluice valve all as directed. |
| 70 | Supply and fixing Steel spindle suitable for 300 mm dia suitable to match the existing sluice valve all as directed. |
| 71 | Supply and fixing gun metal / bronze seat ring suitable for 100 mm sluice valve including machining and fixing completeto match the existing sluice valve all as directed |
| 72 | Supply and fixing gun metal / bronze seat ring suitable for 150 mm sluice valve including machining and fixing completeto match the existing sluice valve all as directed |
| 73 | Supply and fixing gun metal / bronze seat ring suitable for 200 mm sluice valve including machining and fixing completeto match the existing sluice valve all as directed |
| 74 | Supply and fixing gun metal / bronze seat ring suitable for 250 mm sluice valve including machining and fixing completeto match the existing sluice valve all as directed |
| 75 | Supply and fixing gun metal / bronze seat ring suitable for 300 mm sluice valve including machining and fixing completeto match the existing sluice valve all as directed |
| 76 | Supply and fixing gun metal stem nut suitable for 100 mm sluice valve including machining and fixing completeto match the existing sluice valve all as directed |
| 77 | Supply and fixing gun metal stem nut suitable for 150 mm sluice valve including machining and fixing completeto match the existing sluice valve all as directed |
| 78 | Supply and fixing gun metal stem nut suitable for 200 mm sluice valve including machining and fixing completeto match the existing sluice valve all as directed |
| 79 | Supply and fixing gun metal stem nut suitable for 250 mm sluice valve including machining and fixing completeto match the existing sluice valve all as directed |
| 80 | Supply and fixing gun metal stem nut suitable for 300 mm sluice valve including machining and fixing completeto match the existing sluice valve all as directed |
| 81 | Supply & fix of rubber packing sheet 6 mm Thick all as specified and directed. |
| 82 | Supply & fix MS nut and bolt including washer suitable for fixing sluice valve all as specified and directed. |
| 83 | Taking up unserviceable CI sluice valve and Supply and fixing and replacement of sluice valve 200 mm dia type PN-1.6 double Flanged cast iron type with brass spindle and iron wheel iron nuts, bolts & washers and rubber insertion sheet conforming to IS specification complete and all as specified. as following sizes . Make: ISI make PN 1.6 Cair/ BIR/ UPADHYA/Balaji |
| 84 | All as item srl no-36 here in before but size of sluice valve 150 mm dia |
| 85 | All as item srl no-36 here in before but size of sluice valve 100 mm dia |
| 86 | All as item srl no-36 here in before but size of sluice valve 80 mm dia |
| 87 | Supplying and fixing DI butterfly valve of 100 mm PN -16 rating confirming to IS 13095 with epoxy coated body , stainless steel disc and shaft, EPDM seat, gear operated , suitable for water supply pipie line including nuts, bolts, rubber gasket and complete all as directed |
| 88 | Supplying and fixing DI butterfly valve of 150 mm PN -16 rating confirming to IS 13095 with epoxy coated body , stainless steel disc and shaft, EPDM seat, gear operated , suitable for water supply pipie line including nuts, bolts, rubber gasket and complete all as directed |
| 89 | Supplying and fixing DI butterfly valve of 200 mm PN -16 rating confirming to IS 13095 with epoxy coated body , stainless steel disc and shaft, EPDM seat, gear operated , suitable for water supply pipie line including nuts, bolts, rubber gasket and complete all as directed |
| 90 | Taking up unserviceable non return valve of 150 mm dia size from existing pipe line, supply and fixing the same size and connection complete all as directed. |
| 91 | All as item srl no-43 here in before but size of sluice valve 100 mm dia |
| 92 | All as item srl no-43 here in before but size of sluice valve 80 mm dia |
| 93 | Repair of brick mansory valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 100mm size, with , brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and removing the debris from the site or as specified and all as directed. |
| 94 | Repair of brick massonry valve pit chamber of inner dimension 120x120x120 cms suitable for sluice valves upto 100mm size, with , brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and removing the debris from the site or as specified and all as directed. |
| 95 | Repair of brick massonry valve pit chamber of inner dimension 150x50x150 cms suitable for sluice valves upto 100mm size, with , brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 2 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and removing the debris from the site or as specified and all as directed. |
| 96 | Supply & fix Cross arms,bracings,supports,clamps and back plates,fabricated from structural steel sections including nuts,bolts,washers,welding,bending,cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as directed.MS nut and bolt including washer suitable for fixing sluice valve all as specified and directed. |
| 97 | Taking down unserviceable Air Release Valves , supply and fixing connecting Air release valve 50 mm dia with single air Outlets, conforming to IS 14845 and fixing up in Cast Iron Water supply mains of any size mm dia Complete all as specified.Make :- Normax/ BIR/ Kirloskar |
| 98 | Excavation in trenches for soft and loose soil taking out/laying of pipes line not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide in soft/loose and hard dense soil Complete and all as specified the following. |
| 99 | Returning filling including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each layer of soft/loose soil complete and all as specified. |
| 100 | Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point. Complete and all as specified. |
| 101 | M&L PCC 1:4:8 type D2 with 40 mm stone graded aggregate as in foundations and mass concrete |
| 102 | Demolition of Concrete of any description and in any position not otherwisespecifically provided for Cement concrete (unreinforced) |
| 103 | Demolition Brickwork or stone/boulder masonry, including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar or cement lime mortar |
| 104 | M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 |
| 105 | M&L Rendering cement plaster 10 mm thick on brick /concrete surface in CM (1:4) finished fair and even without using extra cement |
| 106 | Taking out unserviceable CI Foot valve any type, supply and fixing CI Foot valve 200mm with one end flanged and neuprone ball with jointing material such as insertion of rubber sheet 3mm thick with MS nut and bolt 12mm dia X 40mm long complete of following sizes |
| 107 | All as item no-59 here in before but 150 mm dia |
| 108 | All as item no-59 here in before but 100 mm dia |
| 109 | All as item no-59 here in before but 80 mm dia |
| 110 | Supply potassium aluminum sulfate non ferric Alum cakefrom 17% Purity as per IS-260..Make :Arihant |
| 111 | Collecting, Transporting and testing of water sample from Raw water and Treated water at three pump houses for all physical and chemical parameters through NABL accredited and ISO certified laboratory on quarterly basis including submission of complete test reports as per relevant ISO standards and as per directed. |
| 112 | Repair of Defects such as leakage and blockage in GI pipe of size 15 mm to 80 mm including T&P and neccesary excavation work upto 6 RM and depth up to 60 cm manually or by JCB (Extractor) and refixing again after cutting,threading and jointing as per site requirement using new GI fittings as required following sizes:- Note :- (a) fittings reqd will be paid Separately. (b) Defects shoud be rectified within 24 Hrs of intimation otherwise recovery @ of rupees 300 per day will be carried out (c) Contractor shall be responsible to repair defects at any place or area under GE dehu Road. |
| 113 | Suply for repair GI Elbow 15mm. Make: Jindal,TATA |
| 114 | Suply for repair GI Elbow 20 mm. Make: Jindal,TATA |
| 115 | Suply for repair GI Elbow 25mm. Make: Jindal,TATA |
| 116 | Suply for repair GI Elbow 40 mm. Make: Jindal,TATA |
| 117 | Suply for repair Tee 15mm.Make: Jindal,TATA |
| 118 | Suply for repair Tee 20 mm.Make: Jindal,TATA |
| 119 | Suply for repair Tee 25 mm.Make: Jindal,TATA |
| 120 | Suply for repair Tee 40 mm.Make: Jindal,TATA |
| 121 | Suply for repair Union 15mm.Make: Jindal,TATA |
| 122 | Suply for repair Union 20 mm.Make: Jindal,TATA |
| 123 | Suply for repair Union 25mm.Make: Jindal,TATA |
| 124 | Suply for repair Union 40 mm.Make: Jindal,TATA |
| 125 | Supply for repair Coupling(GI Socket 15mm) Make: Jindal,TATA |
| 126 | Supply for repair Coupling(GI Socket 20 mm) Make: Jindal,TATA |
| 127 | Supply for repair Coupling(GI Socket 25mm) Make: Jindal,TATA |
| 128 | Supply for repair Coupling(GI Socket 40 mm) Make: Jindal,TATA |
| 129 | Supply for repair Nipple 15mm Make: Jindal,TATA |
| 130 | Supply for repair Nipple 20mm Make: Jindal,TATA |
| 131 | Supply for repair Nipple 25mm Make: Jindal,TATA |
| 132 | Supply for repair Nipple 40 mm Make: Jindal,TATA |
| 133 | Supply for repair Stop plug 15mm Make: Jindal,TATA |
| 134 | Supply for repair Stop plug 20 mm Make: Jindal,TATA |
| 135 | Supply for repair Stop plug 25mm Make: Jindal,TATA |
| 136 | Supply for repair Stop plug 40 mm Make: Jindal,TATA |
| 137 | Supply for repair Barrel nipple 80mm' long 15mm dia Make: Jindal,TATA |
| 138 | Supply for repair Barrel nipple 80mm' long 20 mm dia Make: Jindal,TATA |
| 139 | Supply for repair Barrel nipple 80mm' long 25mm dia Make: Jindal,TATA |
| 140 | Supply for repair GI Reducer Coupling 20/15mm Make: Jindal,TATA |
| 141 | Supply for repair GI Reducer Coupling 25/20mm Make: Jindal,TATA |
| 142 | Supply for repair GI Reducer Coupling 25/15mm Make: Jindal,TATA |
| 143 | Supply for repair GI Reducer Coupling 50/25mm Make: Jindal,TATA |
| 144 | Supply for repair GI Reducer Elbow 20/15mm Make: Jindal,TATA |
| 145 | Supply for repair GI Reducer Elbow 25/20mm Make: Jindal,TATA |
| 146 | Supply for repair GI Reducer Elbow 25/15mm Make: Jindal,TATA |
| 147 | Supply for repair GI Reducer Elbow 50/25mm Make: Jindal,TATA |
| 148 | Repair of Defects such as leakage and blockage in CI/DI pipe of size 80 mm to 100 mm including neccesary excavation work upto 6 RM and depth up to 60 cm manually or by JCB (Extractor) and refixing again after cutting and jointing as per site requirement using new CI/DI fittings as required following sizes :- Note :- (a) fittings reqd will be paid in respective items (b) Diffects shoud be rectified within 24 Hrs of intimation oterwised recovery @ of rupees 300 per day will be carried out. |
| 149 | Repair of Defects such as leakage and blockage in CI/DI pipe of size 150 mm to 200 mm including neccesary excavation work upto 6 RM and depth up to 60 cm manually or by JCB (Extractor) and refixing again after cutting and jointing as per site requirement using new CI/DI fittings as required following sizes :- Note :- (a) fittings reqd will be paid in respective items (b) Diffects shoud be rectified within 24 Hrs of intimation oterwised recovery @ of rupees 300 per day will be carried out. |
| 150 | Repair of Defects such as leakage and blockage in CI/DI pipe of size 250 mm to 300 mm including neccesary excavation work upto 6 RM and depth up to 60 cm manually or by JCB (Extractor) and refixing again after cutting and jointing as per site requirement using new CI/DI fittings as required following sizes :- Note :- (a) fittings reqd will be paid in respective items (b) Diffects shoud be rectified within 24 Hrs of intimation oterwised recovery @ of rupees 300 per day will be carried out. |
| 151 | material and labour for job work for testing of electric flow meter by rep of OEM of manufacturer as per site requirement & replacing of defective parts all as specified and directed.Note :- Spares will be paid separately. |
| 152 | Converter transmitter |
| 153 | FIT Batch indicator Panel type 96x96x85 |
| 154 | Display 7 Segment |
| 155 | Supply High Strength Calcium based granular chlorination chemical /disinfectant containing appropriate quantities of dispersants (with anti corrosion and desclent ritified by the HQ E-in-C)scaling in distribution system in 45 Kg Container ,(having Available Chlorine 50- 60 % by mass min ,stability loss of chloride on basis of available chloride Max 1/15 ,particle size (passing through 1.7 mm ) IS sieve by mass Min 99.5 % waterinsoluble matter Max 6% Calcium Hydroxide MAx 4% sodium chloride Max 15%)acceptability and being manufactured/ processed in open market |
| 156 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil |
| 157 | M&L for hard core of gauge n.exc 63mm thick of broken boulder spread levelling,watering, ramming to true surface complet all as directed. |
| 158 | M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as directed. |
| 159 | M&L rendering 10mm thick on fair faces of brick work or concrete surfaces inished even and smooth in cement mortar 1:6 complete alas directed. |
| 160 | M&L 10040 Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters ,post etc to Fe-410 gde E-250 quality-A complete all as directe. |
| 161 | M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet /vally gatter complete 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as directed. |
| 162 | M&L for painting with two coat of synthatic enamel paint over a coat of reoxide in new steel surface complete all as directed. |
| 163 | M&L for cement concrete 1: 4:8 type D-2 using 40 mm graded aggregate as in foundation for pole including necessary form work all as specified and directed |
| 164 | M&L for cement concrete 1 : 2 : 4 type B-1 using 20 mm graded aggregate as coaping , filling and mass concrete necessary form work all as specified and directed. |
| 165 | Supply , erect, test and commissioning tube settler module of size 5.6 RM × 5.6 RM consisting of Square PVC tubes made from primary, UV-stabilized, non-reprocessed PVC material conforming to IS 10121 (Part 1 & 2), each 0.5 m long with a minimum wall thickness of 1.05 mm, assembled to cover a plan area of 31.36 m² and installed at an inclination of 55° to 60° for optimum settling efficiency, flow range of 85–158 m³/hr including providing all necessary support framing, along with supplying, fabricating, and installing an MS corbel beam of size not less than 5.6 RM × 6 RM × 0.150 RM fabricated from standard MS sections, including all cutting, welding, and erection works. All MS components shall be coated with one coat of primer and two coats of epoxy paint with proper surface preparation. The job also comprises full installation, leveling, anchoring, and alignment of the tube settler modules, proper fixing of the PVC tubes to the MS supports all as specified and directed. |
| 166 | S&F in replacement Cast Iron body Cold water flow meter flanged end Class B size 150mm ISO standard 4064/1 including any necessary reducers, specials, or fittings to integrate the meter with the pipeline including testing all as specified and directed. |
| 167 | S&F Mild steel, plain, black sheet in wall steel gate and similar work, cut to size,hole punched including round headed screws,clout nails or rivets and fixed to wood or steel framing, in hearths; covering to door shutters; covering to water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets 1.00 mm thickness as required all as specified and directed. |
| 168 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised earth Strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr-in-charge.Note :- (a) Earth work is included in this rate.(b) GI Pipe and GI strip upto 7.5 RM also included in this rate. Please Enable Macros to View BoQ information |