| 1 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : .2.10 |
| 2 | All kinds of soil .2.10.1 |
| 3 | Pipes, cables etc, not exceeding 80 mm dia .2.10.1.1 |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : .4.1 |
| 5 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) .4.1.10 |
| 6 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (Size 300mm x 600mm) .8.31 |
| 7 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required .10.25 |
| 8 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works .10.25.2 |
| 9 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : .11.26 |
| 10 | 25 mm thick .11.26.1 |
| 11 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or ranslucent, clear or pigmented, textured or smooth as specified. .12.47 |
| 12 | 2 mm thick flat .12.47.2 |
| 13 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. .17.28 |
| 14 | Flexible pipe .17.28.2 |
| 15 | 32 mm dia .17.28.2.1 |
| 16 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Internal work - Exposed on wall .18.10 |
| 17 | 15 mm dia nominal bore .18.10.1 |
| 18 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality screwed end) : .18.17 |
| 19 | 20 mm nominal bore .18.17.1A |
| 20 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : .18.46 |
| 21 | 20 mm diameter bore .18.46.2 |
| 22 | Making hole up to 20x20 cm and embedding pipes up to 150 mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) including disposal of malba. .18.79 |
| 23 | Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). .E&M DSR 202532.2 |
| 24 | Inverter Type – Cooling only . |
| 25 | 1.5 TR with 5 Star BEE Rating .32.2.3 |
| 26 | Make: Carrier /Hitachi /Mitshubishi /Daikin /Voltas /Bluestar or any other make as per approved make list. . |
| 27 | Providing and fixing of voltage stabilizer suitable for 1.5 TR air conditioner capacity 15 Amp. Working range 150 VAC - 285 VAC with low and high voltage cut off protection built in thermal overload protection, digital /analog display for input/output voltage with wall mounting metal cabinet, complete of make V-Guard model VND 500 or equivalent model of Deol, Luminious, Microtech. .NSR |
| 28 | Providing & Fixing of Powder coated ready made heavy duty out door stand for Split out door as per site requirement to the entire satisfaction of Engineer- in Charge. .NSR |
| 29 | Providing and Fixing of PVC Rigid drain Pipe complete in all respects from indoor unit to Disposal Points as directed by the E.I.C. Size ¾” including specials Diplast Or Equalivent. .NSR |
| 30 | Providing and Fixing of 22 gauge soft copper piping of size 3/8\\" / 5/8\\" or as per original manufacturer technical specification for A/C size, for Liquid & Suction sides, between indoor & outdoor units with 6 mm thick nitrile rubber insulation & protective covering for exposed whether/chasing including cost of chasing brick wall/RCC wall & repairing to original condition. The rate per meter includes cost of 1 meter No's of both 3/8” & 5/8” with insulation. Make Rajco tubes, Mandev, Maxflow, Totaline. .NSR |
| 31 | Providing & fixing of 3 core 2.5 sqmm flexible copper wire as per specifications Makes Havell, Polycabs or Finolex complete as per site .NSR |
| 32 | Providing and fixing of PVC Trunking Channel to cover the exposed copper pipe cable and drain pipe. .NSR |
| 33 | PVC Trunking 50x100mm (White Color) . |
| 34 | Providing and fixing of drinking water cooler model 380 to 400 ltrs cap/cooling cap 150 to 170 ltrs/Hr. full body stainless steel SS 304, with non CFC hermetically sealed reciprocating/ rotary compressor complete in all respect.Make: Sidwal / Blue Star / Climatrol .NSR |
| 35 | Providing and Fixing of Hi flow water filter with cum-purifier including installation charges 3 Ltrs./Minute. Make:- Aqua Guard/ Kent .NSR |
| 36 | Providing and Fixing of 3\\" Dia. PVC pipe of 6 Kg/cm2 pressure complete as per specifications. .NSR |
| 37 | Providing and Fixing of 3\\" Dia. PVC FT of 6 Kg/cm2 pressure complete as per specifications. .NSR |
| 38 | Providing and Fixing of PVC Connection embedded (1.0 meter) for water cooler at various sites in Chandigarh complete as per specifications. .NSR |
| 39 | Providing and Fixing of C.P. Steel Grating Heavy (with hole without hole) size .NSR |
| 40 | Providing & fixing IRC encloser jali of mesh size 40 mm x 40 mm of 10 gauge with frame work of MS angle 40x40x5 mm and MS flat 32x5 mm including painting with two coats of synthetic enamel paint over a coat of steel arrangeent all as specified. (Size of angle grid should not be more than 12 sft) with two coats of black paint as per site requirement as desired by EIC .NSR Please Enable Macros to View BoQ information |