| 1 | Surface Excavation : Surface excavation in soft/loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out |
| 2 | Removal : Removing excavated material(soils) exc. 250m but n.exc 500m and depositing where directed. |
| 3 | Demolition : Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 4 | PCC 1:4:8 : (M&L) - Plain Cement concrete (1:4:8), type D2 with 40 mm graded aggregate, in foundation, filling and mass concrete complete all as specified. |
| 5 | Excavating In Post Holes: Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, |
| 6 | Hardcore: (M&L) Hardcore (broken stone or boulders) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 7 | Moorum : Supply and filling of Moorum/Red Bajri, filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 8 | Glass : (M&L) Sheet glass 4 mm thk., ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane |
| 9 | PCC 1:2:4 : (M&L) Cement Concrete 1:2:4 type B2 with 40 mm graded aggregate in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts |
| 10 | Precast Concrete : Providing precast cement concrete Type B1, 1:2:4 with 20 mm graded aggregate set in Cm 1:6 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces |
| 11 | Structural Steel : (M&L) Rolled mild steel (Fe 410 Gd E 250 Qlty A) in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) |
| 12 | Fixing of Chain Link fencing : Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire |
| 13 | Supply of Chain Link Fencing : Supply only of Chain link MS galvanisd fencing, any size or type |
| 14 | Steel Windows : (M&L) Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded |
| 15 | MS Door : (M&L) Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded |
| 16 | Cement Paint Of Walls : M&L : Cement painting on fair faced walls - previously treated surfaces incl. preparation of surfaces - TWO coats complete all as directed. Brand: Snocem/ Indocem |
| 17 | Whitewash Of Walls : M&L : White washing on fair faced walls - previously treated surfaces incl. preparation of surfaces - TWO coats complete all as directed. |
| 18 | Enamel Paint to Steel : (M&L) Synthetic Enamel Painting on previously treated Steel surfaces over 10 cm width or girth including preparation of surfaces, ONE coats complete all as specified and directed, Brand: Asian Paints Asian Paints Apcolite/ Berger Luxol Gloss/ Nerolac Impressions. |
| 19 | Brickwork : (M&L) Brickwork with subclass B bricks straight or curved in plan exc 6m mean radius built in cement mortar 1:6 |
| 20 | Precast Block Masonry : (M&L) Pre-cast cement concrete block masonry with solid blocks Type C1, 1:3:6, 20 mm graded aggregate, set in CM 1:6, exc. 10 cm in width and setting in mortar, complete |
| 21 | Flush Pointing : (M&L) Flush pointing to block in course or ashlar masonry or concrete block walling with 1:4 cm |
| 22 | Plastering : Rendering 10 mm thick cement plaster 1:6 on fair faces of brickwork or concrete surfaces. |
| 23 | Taking Down carefully copper/Aluminium point wiring (Light, Fan, Socket, Power point) complete (fittings such as switches, ceiling roses, pendents, regulators, sockets, etc to be measured seperately) removing material to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc. Complete all as specified and directed. |
| 24 | Taking Down carefully by unscrewing from board /outlets boxes fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tubelight fittings and regulators etc for reuse at site or carrying to the store (to be measured only when found serviceable in all respect complete for reuse). Complete all as specified and directed. |
| 25 | Point wiring: Supply and fixing / Drawing of cables in PVC conduit of 1\\"or 3/4\\" Dia ,one Light point or one fan point controlled by one switch with cables 1.5 sq.mm size of FR PVC single core, copper conductor, Each point should have seperate phase, neutral and earth wire. Make: Finolex/ Havells/ polycab/L&T in PVC conduit,includes all accessories like bends, tees,screws,clips ,plugs, clamps,junction boxes, cutting holes in or through walls,fixing of boards and grouted into the wall,earth wire etc and testing as specified. All connections to be given by copper Pin/eye type lugs including for earth connections. Complete all as specified and directed. |
| 26 | Point wiring: Supply and fixing /Drawing of cables in PVC conduit of 1\\"or 3/4 \\" Dia ,one 3 pin socket outlet 15 amps independent, with 4.0 sq.mm size of copper conductor cables FR PVC.Each point should have seperate phase,neutral and earth wire. Make: Finolex/Havells/Polycab/L&T in PVC conduit, includes all accessories like bends,tees, screws, clips, plugs,clamps,junction boxes,cutting holes in or through walls,fixing of wooden boards ,earth wire. All connections to be given by copper Pin/ eye type lugs including for earth connections.Complete all as specified and directed. |
| 27 | Ceiling Rose: Supply and fixing of ceiling rose, PVC/Polycorbonate, 3 terminal Make: Legrand/Schneider/Havells of ISI quality. Complete all as specified and directed. |
| 28 | 6A Switch Modular: Supply and Fixing of modular switch 1 way, 6 amps, one module, Make: Legrand/Schneider/Havells of ISI quality. Complete all as specified and directed. |
| 29 | 16A Switch Modular: Supply and Fixing of modular switch, one way 16 amps, one module. Make: Legrand/Schneider/Havells of ISI quality. Complete all as specified and directed. |
| 30 | 16A Socket Modular: Supply and Fixing of modular socket outlet 6/16 amps,3 pin, combined 2 module. Make: Legrand/Schneider/Havells of ISI quality. Complete all as specified and directed. |
| 31 | Covering Plates with frame: Supply and Fixing of modular white colour covering plates with frame of 8 module. Make: Legrand/Schneider/Havells. Complete all as specified and directed. |
| 32 | Covering Plates with frame: Supply and Fixing of white colour covering plates with frame of 4 module. Make: Legrand/Schneider/Havells. Complete all as specified and directed. |
| 33 | Metal Flush Box : Supply and Fixing of modular metal flush box, 4 module for mounting switches and sockets. cable terminations to be done neatly with lugs, grouted into the wall. Make: Legrand/Schneider/Havells. Complete all as specified and directed. |
| 34 | Supply and fixing of Sheet Metal enclosures for DB(MCB DB), single pole and neutral 8 way with 200 Amps rated bus bar, 240V, Double Door Make: Schneider/Legrand/Havells/L&T. Complete all as specified and directed. |
| 35 | Fixing of LED batten tube light fitting of 20 wattage, including connections. Complete all as specified and directed. (Material will be supplied by OFMK) |
| 36 | Supply and Fixing of Galvanised steel tube 40mm dia light grade, on side walls of building suitable for fixing street light fitting including bending the pipe to the required shape, with clamps, with required welding, Painting the flat iron with primer and finish paint. Complete all as specified and directed. |
| 37 | Supply and Fixing of miniature circuit breaker (MCB), SP, 5 To 32 AMP rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning. |
| 38 | Supply and Fixing of miniature circuit breaker (MCB), SPN, 40 To 63 AMP rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning. |
| 39 | SUB MAIN WIRING: Supply and fixing of wiring for Circuit/Sub Main wiring along with earth wire with following sizes of FR PVC Insulated copper conductor single core cable 2x10.0 Sq.mm + 1x10.0 sq.mm earth wire in PVC Conduit. Make Finolex/ Havells/ Polycab/ L&T. Complete all as specified and directed. |
| 40 | Supply and fixing LED street light fitting 35 Watt 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete . Make: Crompton/Wipro/Philips. |
| 41 | Supply and fixing of exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers Make: Havells/ Crompton/ Bajaj/ Usha. Complete all as specified and directed. |
| 42 | Cutting Chases: Cutting chases on brick walls for MCB DBS, wiring and MS boxes for mounting switches, MCBs exceeding 20 cm girth, pinning in, making good to facings where required and pointing in cement mortor 1:3 to ends or edges etc. Complete all as specified and directed. |
| 43 | Earthing : Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edges of plate not less than 1.5 M below normal ground level, connected to 25mmx4 mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel connected to earthing test point all as specified including testing on completion. Complete all as specified and directed |
| 44 | Earth continuity conductor: Main earthing lead fixing to wall on batten or recess or chases or buried in around or drawn in conduit pipe or fixing to poles or any other indicating situation for loop earthing etc as required 25mmx4mm GI strip. Complete all as specified and directed. |
| 45 | Galvanised Steel Tube: Material and labour for galvanised steel tube medium grade 40 mm bore to protect earthing strip. Complete all as specified and directed. |
| 46 | Galvanised Steel Tube: Material and labour for galvanised steel tube medium grade 20 mm bore for water pipe. Complete all as specified and directed. |
| 47 | TMT Bars: Mild steel bars (TMT bars), 10mm dia and over, cut to desired length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips. Complete all as specified and directed. |
| 48 | Excavation: Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sq m on plan and not exc 1.5 m in depth and getting out. Complete all as specified and directed. |
| 49 | Returning, Filling: Returning, filling in, in hard/dense soil including speading, levelling, watering and well ramming in layers not exc 25 cm. Complete all as specified and directed. |
| 50 | Precast Hollow Concrete Blocks: Type B1 1:2:4 (20mm graded aggregate) in covers slabs set in cement mortar 1:6 for earth pits with plain faces size (40x40x5cm). Complete all as specied and directed. |
| 51 | Cement concrete : Providing cement concrete cast in situ for each pit chamber slightly rounded or chamfered angles including finishing by using type B1 1:2:4 (20mm graded aggregate). Complete all as specified by the EIC. |
| 52 | Supply and Fixing of 2 KVA inverter with tubular batteries(02 No's X 150Ah,24V )combo pure sine wave unit Make: Luminous Optimus 2300 or equivalent of Microtek/V-Guard. Complete all as specified and directed. |
| 53 | Supply and Fixing of modular metal flush box, 12 module for mounting switches and sockets. cable terminations to be done neatly with lugs, grouted into the wall. Make: Legrand/Schneider/Havells. Complete all as specified and directed. |
| 54 | Supply and Fixing of modular metal flush box, 8 module for mounting switches and sockets. cable terminations to be done neatly with lugs, grouted into the wall. Make: Legrand/Schneider/Havells. Complete all as specified and directed. |
| 55 | Supply and Fixing of modular white colour covering plates with frame of 12 module. Make: Legrand/ Schneider/Havells. Complete all as specified and directed. Please Enable Macros to View BoQ information |