| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: 2.9.1 All kinds of soil : |
| 2 | Providing and laying of stone soling, hand packed, including carriage of same from approved source upto site of work complete. |
| 3 | P/ L in position cement concrete in 1:4:8(1 cement :4coarse sand : 8 graded crushed stone aggregate, 40mm nominal size) excluding the cost of centering and shuttering but including Mechanical carriage of all materials from approved sources up to site of work complete. |
| 4 | P/ L in position cement concrete in 1:3:6(1 cement :3 coarse sand : 6 graded crushed stone aggregate, 40mm nominal size) excluding the cost of centering and shuttering but including mechanical carriage of all materials from approved sources up to site of work complete. |
| 5 | Brick work with F.P.S (non modular) bricks of class designation 75 in 1:6 mix (1 cement: 6 coarse sand) in super structure including mechanical carriage of all materials from approved sources upto site of work complete. (above plinth level upto floor V ) |
| 6 | Reinforced cement concrete work in 1: 1.5 : 3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size)excluding the cost of centering, shuttering, finishing and reinforcement but including mechanical carriage of all materials from approved sources upto site of work complete.( All works upto plinth level) |
| 7 | Reinforced cement concrete work in 1: 1.5 : 3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size)excluding the cost of centering, shuttering, finishing and reinforcement but including mechanical carriage of all materials from approved sources upto site of work complete.( All works above plinth level upto level V) |
| 8 | Reinforcement for RCC work including straightening cutting, bending, placing in position and binding all complete (Thermo mechanically treated bars) including all carriages complete. |
| 9 | structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. welded |
| 10 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In all colours, shades, except White, Ivory, Fume Red Brown |
| 11 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 12 | 12 mm thick cement sand plaster in 1:4 with all leads lifts, carriage and curing |
| 13 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 14 | Centering & shuttering including strutting, propping etc including removal of form work for Foundations,, footings, bases of columns ,ramp,steps etc. for mass concrete. |
| 15 | Centering & shuttering including strutting, propping etc including removal of form work Suspended floors, roofs, landings, balconies and access platforms. |
| 16 | Providing and fixing uPVC SWR pipe Type B conferming to Is 13592 with all necessary fittings and fixtures (Prince fenolac or eqv) |
| 17 | 100 mm dia |
| 18 | PVC Collar 100 mm |
| 19 | PVC Floor trap with jali |
| 20 | Providing and fixing of GI Pipe Type Bwith all GI Fittings and making good on walls 15 mm dia |
| 21 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 22 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank three layer supreme , comfort, vectus, syntex or eqvISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 23 | Providing/Fixing of cp brass fittings of standard quality like jaquar, cera, hindware or eqv conferming to IS:8931 sample to be approved by incharge engineer |
| 24 | Bib cock long body |
| 25 | angle value |
| 26 | PVC Connections |
| 27 | Providing and fixing of 1' x1' PVC Heavy duty Cover with frame includig embending in cement concrete all complete as p[er the directions of incharge enginer at site |
| 28 | Providing and fixing of Precast Concrete rings 3' dia in sakage pit with all lkeads and lifts and carriage of same |
| 29 | Providing and fixing of Precast Concrete lid dia in sakage pit with all lkeads and lifts and carriage of same |
| 30 | Head load of 1 Km for stone agg |
| 31 | Head load of 1 Km for Sand |
| 32 | Head load of 1Km for Bricks |
| 33 | Head load of 1 km for stone soling Please Enable Macros to View BoQ information |