| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit including supply of conduit, with modular switch (Anchor roma urban/ Eq. make), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable etc. asrequired ..(Havell/V-gard/Anchor Roma urban).(1.10) |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell/Anchor/ Eq. make), single core cable in surface/ recessed medium class PVC conduit as required(a) 2x 1.5 sq. mm Inverter main |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell/Anchor/ Eq. make), single core cable in surface/ recessed medium class PVC conduit as requiredb) 2 X 2.5 sq. mm+ 1 X 2.5 sq. mm earth wire |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell/Anchor/ Eq. make), single core cable in surface/ recessed medium class PVC conduit as required(c) 2 X 4 sq. mm+ 1 X 4 sq. mm earth wire |
| 5 | Supply and fixing of 16/20 amp/230 V AC 6 pin sockets with cover plate Anchor Roma urban/SSK NV/Havells/ Eq. make. |
| 6 | Supply and fixing of 16/20 amp/230V AC one way switch with cover plate Anchor Roma urban/S5K NV/Havells/ Eq. make. |
| 7 | Supply and fixing of 6 amp/230 V AC 5 pin sockets with cover plate Anchor Roma urban/SSK NV/ Eq. make. (one inverter socket /room) |
| 8 | Supply and fixing of 10 amp/230 V AC one way switch with cover plate Anchor Roma urban/SSK NV/Havells/ Eq. make. |
| 9 | Supplying and fixing of following sizes modules, GI boxalong with modular base & cover plates for modular switches In recess etc as required.12 Module |
| 10 | Supplying and fixing of following sizes modules, GI boxalong with modular base & cover plates for modular switches In recess etc as required.6 Module |
| 11 | Supplying and fixing of following sizes modules, GI boxalong with modular base & cover plates for modular switches In recess etc as required. 4 Module |
| 12 | Supply installation testing and comm. Of 1200 mmceiling fan Model oyster Metallic Havell make/Bajaj/Crompton(Flavia) of eq. standard ( strictly as per approved sample) |
| 13 | Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma urban/SSK NV/ Eq. make. |
| 14 | Providing and Fixing of 9 watt led bulb (LMR) Make:- Anchor/orient/havelis/equalent |
| 15 | Supply fixing testing and comm. Of backlite holder/batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block |
| 16 | S/F testing and comm. Of recessed/ surface mounted ceiling 10/12 Watt LED down lighters philips /Havell/ Bajaj/ Crompton make of eq. standard. (2 inverter lights /room) |
| 17 | Supplying ,installation,testing and commissioning of surface 20 watt LED flood lights outdoor Lamp(Grey) as per ISi Standards as Security lights for outside of Building complete |
| 18 | Supply and installation of 200-275 mm with self closing louvers exhaust fans as per ISI Standard |
| 19 | S/F testing and comm. Of MCB's of the belowmentioned capacities in sub main controls legrand C curve Series.b) 6-32 Amp SP MCB |
| 20 | S/F testing and comm. Of MCB's of the belowmentioned capacities in sub main controls legrand C curve Series.c) 4O-63amp DP MCB |
| 21 | Supplying and fixing of 16 way, double door single pole and neutral ,sheet steel,mcb distribution board,240 V ,on surface/recess,complete with tinnedcopper bus bar ,neutral bas bar,earth bar,dinbar,interconnection ,powder painted including earthing etc as required.(But Without MCB/RCCB/ISOLATOR) |
| 22 | Supply, laying partly overhead partly underground, testing and comm. Of 16mm 2 core 650/1100 V gradeunarmoured Aluminium cable Havell/Eq. standard |
| 23 | Providing Earting by laying 35 mm GI Pipe in a pitconnected through GI Strip with main panel andrefilling the pit with alternate layers of charcoal, salt ndclay chemical earthing Please Enable Macros to View BoQ information |