| 1 | BoQ BOQ Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER TEZPUR (NORTH) NAME OF WORK : REPAIR / MAINTENANCE OF IRON REMOVAL PLANT & FILTERATION PLANT OF PUMP HOUSES OF ZONE 7A, 7B, 8, 9, 10 AND CLEANING OF UG/OVER HEAD RESERVOIR UNDER GE(N)TEZPUR. Contract No : GE(N)/TEZ/ OF 2026-2027 (File No. 8263) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Description of items of works Item Code / Make Approx No. of quentity required. Units Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures to be entered by the Bidder Rs. P. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT (In INR) TOTAL AMOUNT With Taxes TOTAL AMOUNT (In Words) |
| 2 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth in soft / loose/Hard soil and getting out for removing / laying of pipe lines Complete all as specified and as directed. |
| 3 | Returning and filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick all as specified and directed by Engr-in-Charge. |
| 4 | Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point Complete all as specified and as directed. |
| 5 | Supply and Laying in replacement MS Pipe of 100mm dia, heavy grade including all fittings such as flange, bend, tee, elbow,reducer etc, laid in trenches/floor for filteration plant Complete all as specified and as directed. |
| 6 | Supply and Laying in replacement MS Pipe of 150mm dia, heavy grade including all fittings such as flange, bend, tee, elbow,reducer etc, laid in trenches/floor for filteration plant Complete all as specified and as directed. |
| 7 | Supply and Fixing in replacement GI pipe of 150mm dia and medium grade inclduing all fittings such as bend, tee, elbow, union, reducer etc, fixed complete on wall / surface / floor including MS hooks / clamps of suitable size Complete all as specified and as directed. |
| 8 | Supply and Fixing in replacement GI pipe of 100mm dia and medium grade inclduing all fittings such as bend, tee, elbow, union, reducer etc, fixed complete on wall / surface / floor including MS hooks / clamps of suitable size Complete all as specified and as directed. |
| 9 | Supply and Fixing in replacement GI pipe of 50mm dia and medium grade inclduing all fittings such as bend, tee, elbow, union, reducer etc, fixed complete on wall / surface / floor including MS hooks / clamps of suitable size Complete all as specified and as directed. |
| 10 | Re-laying existing MS/CI pipe in trenches upto 150 mm dia pipe at filteration plant with old/new fittings such as bends, elbows, union, tees, reducers etc; at site after discaling/cleaning of pipe (Internaly/Externally ) in existing trench or at new location including all pipe fixing arrengement complete all as specified & directed by Engineer -In-charge. |
| 11 | Supply and fix in repair GI nozzles made out of 100 mm GI pipe of length 0.6 Mtr each in sedimentation tank complete with provision of cap on top (as per existing) and fixing with 200/150 mm GI pipe medium grade (lateral and Header pipe) and painting the same properly with black bituminous paint complete all as specified and directed. Note : Cost of necessary welding if required at site is also deemed to be included in the quoted rates. |
| 12 | Supply and fix in repair GI Nozzles in filter bed made out of 80mm dia medium grade GI pipe of length 1.1 Mtr each one end threaded and making requisite nos of holes as per exisitng and fixing with lateral pipe of size 200/150 mm in filter bed complete all as specified and as directed. |
| 13 | M&L for MS angle iron/net framework for covering the sedimentation tank of pump houses 7A,7B,8,9&10 incl iron cage/net for protection from monkeys complete all as specified and directed by Engr-in-Charge. |
| 14 | Supply and fixing in replacement of main entrance glow sign board of size 5mx90cm x30 cm wide made out of MS sheet/acrylic material with front of the board made out of transparant perspex sheet /flex sheet with letter writting (as reqd and approved by Enge-in-Charge) including letter glow fittings. including three core wire of size 40/0.0076mm required length including point wiring,LED driver and painting complete all as specified and directed. Note the location of site are 7A,7B,8,9&10 Pump House. |
| 15 | Supply and fixing in repair/replacement Butterfly valve with spindle, gasket bolts, nuts and washers in position of 150 mm bore in IRP supply and delivery complete all as specified and directed by Engr-in-charge. |
| 16 | Supply and fixing in repair/replacement Butterfly valve with spindle, gasket bolts, nuts and washers in position of 100 mm bore in IRP supply and delivery complete all as specified and directed by Engr-in-charge. |
| 17 | Supply and fixing in repair /replacement Non return valve vertical/horizontal type (Suitable as per existing valve) with gasket bolts, nuts and washers in position of 150 mm bore in IRP supply and delivery complete all as specified and directed by Engr-in-charge. |
| 18 | Supply and fixing in replacement Non return valve vertical/horizontal type (Suitable as per existing valve) with gasket bolts, nuts and washers in position of 100 mm bore in IRP supply and delivery complete all as specified and directed by Engr-in-charge. |
| 19 | Supply & Fixing in replacement of Liquid chlorine dozer, Electronic dozing Unit with Postive displacement diaphram type actuated by a solinoid and a solid state Pulsor with adjustable dozage output, suitable for maximum injector Pressure of 7.5 Kg / CmSq and maximum dozage of 4 Ltr/Hrs including LDPE /FRP Coated solution tank of 100 Ltr capacity fitted with motor, gear agitator, level gauge, lid and inlet / outlet connection and all accessories such as Hypalon Diaphram teflon lined,Polypropylen head,Body,Disc,Suction Pipes,Spaceers,PVC Foot valve and syphon valve complete etc,all as specified and as directed Make : RMCO RC-11 chlorine dosing unit Model : CDS 100 or ELECTROSET AQUA PURIFIERS LTD ( Model No : EA-15 ) or Equivalent make as approved by GE. |
| 20 | Supply & Fixing in replacement of Alum/Soda dozer,Electronic dozing Unit with Postive displacement diaphram type actuated by a solinoid and a solid state Pulsor with adjustable dozage output, suitable for maximum injector Pressure of 7.5 Kg / CmSq and maximum dozage of 4 Ltr/Hrs including LDPE /FRP Coated solution tank of 100 Ltr capacity fitted with motor, gear agitator, level gauge, lid and inlet / outlet connection and all accessories such as Hypalon Diaphram teflon lined,Polypropylen head,Body,Disc,Suction Pipes,Spaceers,PVC Foot valve and syphon valve complete etc,all as specified and as directed Make : RMCO RC-11 chlorine dosing unit Model : CDS 100 or ELECTROSET AQUA PURIFIERS LTD ( Model No : EA-15 ) or Equivalent make as approved by GE. |
| 21 | S & F in replacement pressure gauge with isolating valve and siphon 7Kg x 4\\" dial premium quality material body of pressure rating as per sample/as per site complete all as directed by Engineer-In-charge. |
| 22 | S & F in replacement Flow meter transparent type embedded with filteration plant (Oxidation Chamber) premium quality material body of existing pressure rating as per sample complete all as directed by Engineer-In-charge. |
| 23 | Labour for taking out of old and not reuseable supporting bed(pebbles/gravel) and media bed(MnO2/Anthracite/Acticated carbon) from filter plant for Pump houses 7A,7B,8,9&10 all complete as specified and directed. |
| 24 | Supply and laying in layer MNO2 (Maganese dioxide) compound in filter media plant after isolate the system/bypass the system and opening of filter media as per instruction given by Engineer-In charge complete all as specified and directed . |
| 25 | Supply and laying in layer Anthracite coal in filter media plant after isolate the system and opening of filter media as per instruction given by Engineer-In charge complete all as specified and directed . |
| 26 | Supply and laying in layer sand(16/32) in filter media plant after isolate the system and opening of filter media as per instruction given by Engineer-In charge complete all as specified and directed . |
| 27 | Supply and laying in layer crushed gravel of 2-6 mm size in filter media plant after isolate the system and opening of filter media including reuse of existing gravels as per instruction given by Engineer-In charge complete all as specified and directed . |
| 28 | Supply and laying in layer pebbles of 6-10 mm size in filter media plant after isolate the system and opening of filter media including reuse of existing gravels as per instruction given by Engineer-In charge complete all as specified and directed . |
| 29 | Supply and laying in layer pebbles of 12-20 mm size in filter media plant after isolate the system and opening of filter media including reuse of existing gravels as per instruction given by Engineer-In charge complete all as specified and directed . |
| 30 | Supply and laying in layer pebbles of 25-40 mm size in filter media plant after isolate the system and opening of filter media including reuse of existing pebbles as per instruction given by Engineer-In charge complete all as specified and directed .Note: Filter media will be replaced as per direction of OEM |
| 31 | Supply and lying in layer activated charcoal in activated carbon filter media plant after isolate the system opening of filter media complete all as specified and directed by Engineer-In charge. |
| 32 | Supply and lying in layer 50-63mm in filter media plant after isolate the system opening of filter media complete all as specified and directed by Engineer-In charge. |
| 33 | Material and labour for applying two coats of approved quality anti corrosive bituminous paint suitable for potable water to internal surface of the sedimentation tank, filter bed & filtered water tank , inner surface gravity filter incl all nozzle, pipes etc complete all as specified and directed by Engineer-In charge. (Total = 40000 Glns capacity, PH No 7A, 8 ,9 & 10) |
| 34 | M&L for seven stage cleaning and sterilization of inside the RCC / Steel Underground/semi underground/Over head/Sedmentation/clear water sumps of following capacity through bacteriological treatment by using TERBAC G5/Inchor-5/NB-10/ TERBAC-G-65/ Inoxi-60/NB-69 AND ULTRA VIOLET RAY. Seven stages are as:- (a) First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b) Second stage is cleaning all the algae formation inside the tank by using TERBAC G10/ Inoxi-60/NB-69 a laboratory tested branded chemical of the company ans scrubbing the walls of the tanks. (c) Third strage is fresh water cleaning by high speed jet pump. (d) Fourth stage and first bacteria screening is decertification by using TERBAC-G5/ Inohor-5/NB-10 a Govt Laboratory certified brannded halogen compound. (e) Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tnk and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65/Inoxi-60/NB-69 . NOTE-1:-(i) Company will submit government laboratory test certificate of terbac-g5/inchor-5/nb-10, terbac-g65/ inoxii-60/nb-69, before cleaning, fix the sticker mentioning the date of cleaning & name of site and also provide certificate confirming the completion of sterilization of water tanks mentioning the name of station and date of cleaning. all the cleaning & sterilization staffs should be under accidental insurance coverage. (ii) outlet pipe of oht should be plugged before cleaning the oht to avoid.entering scals and the same shell be reconnected after cleaning the oht and the quoted rate is deemed to include for the rovision.(iii) sterilization team will be comprised of at least 30% members who are minimum 03 monts certificate holder in water tanks sterilization. (iv) contractor will be responsible for rectification of complaints occurred during cleaning the tank ie. no water in tank/over flow due to broken of float valve/ blockage to be included in quoted rate. Note-2:-the work shall be carried through specilized agency rays cleantech/ inus watertech/ satya enterprise. |
| 35 | Complete all as per item No 33 here-in-above but for capacity 1.00 lakh Gln RCC over head tank. |
| 36 | Complete all as per item No 33 here-in-above but for capacity 0.25 lakh Gln RCC over head tank. |
| 37 | Complete all as per item No 33 here-in-above but for capacity 0.10 lakh Gln steel over head tank. |
| 38 | Complete all as per item No 33 here-in-above but for capacity 0.40 lakh Gln sedimentation tank. |
| 39 | Complete all as per item No 33 here-in-above but for capacity 0.20 lakh Gln sedimentation tank. |
| 40 | Complete all as per item No 33 here-in-above but for capacity 0.40 lakh Gln clear water tank. |
| 41 | Complete all as per item No 33 here-in-above but for capacity 0.50 lakh Gln clear water tank. |
| 42 | Complete all as per item No 33 here-in-above but for capacity 0.25 lakh Gln clear water tank. |
| 43 | M&L for testing of water sample from OHT's/ sumps from various installation as speciefied and directed by the Engineer-in-Charge and test the sample as per IS 10500:2012 at PHE lab of ASSAm Govt. (NABL accredited) or any other NABL accredited laboratory and submit the test report to Engineer-in-ChargeNote: Quoted rate is deemed to be inclusive of collection of water at sumps/OHT's at different location in suitable container and submit for testing . The above specified job shall be carried out at each pump house as under :- (a) PH No. 7A (b) PH No. 7B(c) PH No. 8 (d) PH no. 9 (e)PH No. 10 - 5 Nos. |
| 44 | M & L for painting (type and quality of paint recommended and approved by engineer-in charge) to raising/delivery/wash out /over flow pipe(any type any size) of RCC O/H reservoiror , steel over head reservoiror as per colors code with one coat of synthetic enamel paint from ground level to bottom of the dome of the tank complete all as directed by Engineer-In-charge for Pump house No - 7A . |
| 45 | Complete all as per item No 43 here-in-above but for for Pump house No - 7B. |
| 46 | Complete all as per item No 43 here-in-above but for for Pump house No - 8. |
| 47 | Complete all as per item No 43 here-in-above but for for Pump house No - 9. |
| 48 | Complete all as per item No 43 here-in-above but for for Pump house No - 10. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |