| 1 | M&L Servicing of indoor and outdoor unit of split type/ window AC of 1.5/2.0/3.0 ton capacity of any make by air blowing, cleaning the filter in water and drying in sun, cleaning of drain tray and rectifing water leak, checking and tightning the electrical connection incl provide insulation material on cooling coil and heating coil etc all as specified and directed by Engr-in-charge. |
| 2 | Supply and Refilling Gas/refrigerant (CFC free) in AC Split type/Window 1.5 ton / 2 Ton complete all as specified and directed by Engr-in-charge. |
| 3 | Supply and Refilling gas/refrigerant in Refrigerator having capacity 165 to 315 ltr complete all as specified and directed by Engr-in-charge. |
| 4 | Supply and Refilling Gas charging in Water cooler of capacity upto 60/120 Ltr complete all as specified and directed by Engr-in-charge. |
| 5 | Supply, fixing and commissioning of Compressor for window, 1.5 ton capacity Air Conditioner (AC) complete all as specified and directed by Engr-in-charge. Make:LG/Hitachi/GMCC/emerson. |
| 6 | Supply, fixing and commissioning of Compressor for Split AC, 1.5 ton Capacity complete all as specified and directed by Engr-in-charge. Make:LG/Hitachi/GMCC/emerson. |
| 7 | Supply, fixing and commissioning of Compressor Split and window, 2 ton complete all as specified and directed by Engr-in-charge. Make:LG/Hitachi/GMCC/emerson |
| 8 | Supply, fixing and commissioning Refrigerator compressor of capacity 165 to 180 ltr complete all as specified and directed by Engr-in-charge. |
| 9 | Supply, fixing and commissioning Refrigerator compressor of capacity 210 to 315 ltrs complete all as specified and directed by Engr-in-charge. |
| 10 | Supply, fixing and commissioning Water cooler compressor of capacity 40/80 ltr complete all as specified and directed by Engr-in-charge. |
| 11 | Supply, fixing and commissioning Water cooler compressor of capacity 60/120 ltr complete all as specified and directed by Engr-in-charge. |
| 12 | Supply, fixing and commissioning of relay for split and window AC upto capacity 2 Ton complete all as specified and directed by Engr-in-charge. |
| 13 | Supply, fixing and commissioning of relay for Refrigerator upto 315 Ltr capacity complete all as specified and directed by Engr-in-charge. |
| 14 | Supply, fixing and commissioning of PCB for split/window AC including inverter Split AC upto 2 ton capacity complete all as specified and directed by Engr-in-charge. |
| 15 | Supply and fixing Electronic control PCB for refrigerator upto 315 Ltr capacity all as specified and directed by Engr-in-charge. |
| 16 | Supply and fixing Thermostat of window/split AC of any capacity complete all as specified and directed by Engr-in-charge. |
| 17 | Supply and fixing Thermostat of Refrigerator any capacity complete all as specified and directed by Engr-in-charge. |
| 18 | Supply and fixing Thermostat of Water cooler of any capacity complete all as specified and directed by Engr-in-charge. |
| 19 | Supply and fixing blead with motor Split/window AC of capacity 1.5 TR to 2 TR complete all as specified and directed by Engr-in-charge. |
| 20 | Supply and fixing Fan motor Water cooler of capacity upto 60/120 Ltr complete all as specified and directed by Engr-in-charge. |
| 21 | Supply and fixing swing motor for split AC of any capacity complete all as specified and directed by Engr-in-charge. |
| 22 | Supply and fixing cooling coil for Window/Split AC for any capcity and size complete all as specified and directed by Engr-in-charge. |
| 23 | Supply and fixing heating coil/condenser coil for split/window AC 1.5 TR to 2 TR complete all as specified and directed by Engr-in-charge. |
| 24 | Supply and fixing Reverse valve of AC/Refrigerator/water cooler complete all as specified and directed by Engr-in-charge. |
| 25 | Supply, fixing and commissioning Condenser 50 mfd for Split/Window AC upto 2 Ton capacity complete all as specified and directed by Engr-in-charge. |
| 26 | Supply and fixing timer switch for refrigerator of any capacity complete all as specified and directed by Engr-in-charge. |
| 27 | Supply and fixing remote unit for split type AC of any model/size all as specified and directed by Engr-in-charge. |
| 28 | Supply and fixing Water cooler PVC pipe complete all as specified and directed by Engr-in-charge. |
| 29 | Supply and fixing Float valve 15 mm for water cooler 40 to 120 ltr capacity all as specified and directed by Engr-in-charge. |
| 30 | Supply and fixing Push tap for water cooler any size/capacity all as specified and directed by Engr-in-charge. |
| 31 | Supply and fixing Repair of voltage stabilizer of capacity 4/2/1 KVA, single phase, 230 V AC, 50 Hz all as specified and directed by Engr-in-charge. |
| 32 | Supply and fixing LED Security/Street light fittings 35 watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant inclding thermal management in multiple optics complete with IP 65/66 Protection with GI Pipe light grade bracket 1.2 mtr long 40 mm dia fixed to wall with suitable size 2 Nos MS Clamps including nuts, bolts and washers and making connection with using 1.5 sqmm pvc insulated multi standard copper conductor three single core complete all as specified and diredted. |
| 33 | S & F LED light fitting 1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. Make : Havells cat pat HEXAFT10WLED857SSYMBOPC or equivalent cat part in Make :- Havells/ Phillips/Bajaj/C&S Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher. |
| 34 | Supply and fixing post top lantern LED type 20Watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 35 | Supply and fixing post top lantern LED type 40 Watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 36 | Supply and fixing LED flood light 70 watt, 230 V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and average life of flood light not less than 50000 hours, including clamps, nut, bolts, fixing in wall including 2 sqmm PVC twin core aluminium cable from conductor to street light not less 2.0 metre , testing to satisfaction of Engineer in charge complete all as specified and directed. |
| 37 | Supply and fixing or passing through pipe, stranded conductor 6 Sqmm, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers no more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or circular etc all as specified and directed. |
| 38 | -ditto- but 10 Sqmm. |
| 39 | -ditto- but 16 Sqmm. |
| 40 | Supply , laying , connecting , testing and commissioning of 35 sqmm 3.5 core under ground LT cable XLPE insulated screend , PVC bedded, armourd heavy duty electric cable with stranded aluminium conducter 1100 volts laid in trenches fixed to walls/ drwan through pipe and incl the disturbance surfaceof road making goood with using PCC , fixing the cable with suitable size glands , crimping type lugs etc all as specified and directed. note :- ( excavation , eathwork , sand cusioning and cable protection shall be measured and paid separately ). |
| 41 | -ditto- but 16sqmm 4 core |
| 42 | Excavation in trenches not exceeding 1.5 mtr wide, depth exceeding 1.5 mtr and getting out in hard/dense soil complete all as specified and directed by Engineer-in-charge |
| 43 | Returning, filling incl spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed. |
| 44 | Removing excavated material (soil) not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 45 | M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed.. Note :- Thickness of sand cushioning shall be measured after punning. |
| 46 | Supplying and laying un-reinforced precast concrete cable cover class HV type 1 flat size 300x180mmx40mm complete all as specified and directed Please Enable Macros to View BoQ information |