| 1 | M&L for Excavation in trenches n exc 1.5 m wide and n exc 1.5 m in depth beyond ; for foundation, etc. or for shafts, wells , cesspits, manholes, pier holes etc n exc 10 sqm on plan and not 1.5 m depth and getting out soft/loose soil complete as directed by Engr in charge. |
| 2 | M&L for Excavation in trenches n exc 1.5 m wide and exceeding 1.5 m in depth ; for foundation, etc. or for shafts, wells , cesspits, manholes, pier holes etc n exc 10 sqm on plan and getting out soft/loose soil complete as directed by Engr in charge. |
| 3 | Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed |
| 4 | Removal of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed |
| 5 | M&L for reinforced concrete pipes 150mm bore of pipe, class NP2, laid and jointed complete with collars including cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with incl cement concrete 100mm thick 1:3:6 type D-2 using 40mm graded stone aggregate complete and Demolition of existing pipe complete all as specified and directed. |
| 6 | Except pipes, laid and jointed with collars of 150/200/300 mm bore of pipe including cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested pipe with incl cement concrete 100mm thick 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and directed. |
| 7 | M&L for reinforced concrete pipes 200mm bore of pipe, class NP2, laid and jointed complete with collars including cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 200 mm bore of pipe with incl cement concrete 100mm thick 1:3:6 type D-2 using 40mm graded stone aggregate complete and Demolition of existing pipe complete all as specified and directed. |
| 8 | M&L for reinforced concrete pipes 300mm bore of pipe, class NP2, laid and jointed complete with collars including cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 300 mm bore of pipe with incl cement concrete 150mm thick 1:3:6 type D-2 using 40mm graded stone aggregate complete including Demolition of existing pipe complete all as specified and directed. |
| 9 | Demolition of concrete in ground floors and pavings (unreinforced) nexc 15 cm thickness (below or above ground level). |
| 10 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling of man holes or in similar work and mass concrete complete all as specified and directed. |
| 11 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 12 | M&L fly ash brick work with modular 'B' bricks in cm 1:6 using modular bricks straight or curved on plan to any radius including Demolition all as specified and directed. |
| 13 | Supply only integral water proofing compound all as specified and directed. |
| 14 | M&L 15mm thick rendering in two (10mm+5mm ) CM 1:4 on fair faces of brick/concrete surfaces finished even and smooth w/o using extra cement complete |
| 15 | M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed. |
| 16 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 17 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for any dia of pipe complete all as specified and directed. |
| 18 | S&F TMT bars 6mm to 8mm dia cut to length bent to shape required incl cranking bending & binding with mild steel wire aunealed not less than 0.9mm dia all as per specified |
| 19 | Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete. |
| 20 | M&L RCC (Nominal mix) 1:2:4 type B-1 using 20mm graded stone aggregate slabs supported, beams and columns in floors, cover slab, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. (Note : Reinforcement shall be measured and paid separately) |
| 21 | Form work to edges of concrete cover slabs, flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roof and sides of bands in walls, horizontal or sloping and similar work for rough finished concrete surface exc 8 cm but not exc 20 cm wide complete all as specified and directed. |
| 22 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc including taking down of rain water pipes of any size or pattern including all fittings etc complete all as specified and directed. Make : Finolex/ Kisan/ Supreme/ Prince. |
| 23 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc including taking down of rain water pipes of any size or pattern including all fittings etc complete all as specified and directed. Make : Finolex/ Kisan/ Supreme/ Prince. Please Enable Macros to View BoQ information |
| 24 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc including taking down of rain water pipes of any size or pattern including all fittings etc complete all as specified and directed. Make : Finolex/ Kisan/ Supreme/ Prince. Please Enable Macros to View BoQ information |