| 1 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc in hard/dense soil |
| 2 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil all as directed. |
| 3 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point all as directed. |
| 4 | Supply and laying double walled corrugated HDPE Pipes of size 90 mm dia as per IS 16205 Anti termite, Anti Rodency and Non flame propagation propety etc for protection of LT cables complete all as specified and directed. |
| 5 | Supply and laying double walled corrugated HDPE Pipes of size 63 mm dia as per IS 16205 Anti termite, Anti Rodency and Non flame propagation propety etc for protection of LT cables complete all as specified and directed. |
| 6 | S & F in repair GI Pipe Light grade with all connected accessories of sizes 100 mm dia completed as directed for cable protection |
| 7 | Material & Labour only for taking down XLPE cable any size/type including PCC Cable cover, GI Pipe light grade, etc complete all as specified and directed.Note : Excavation and eartyh work measured and paid seperately |
| 8 | Supply and laying,jointing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 volt grade laid in trenches,ducts,drawn through pipes across the road/path/along poles/floors/equipment etc of size 95 sq mm 3.5 core. |
| 9 | All as per item srl item No.8 here-in-before but of size 50 sqmm 3.5 core |
| 10 | All as per item srl item No.8 here-in-before but of size 25 sqmm 4 core |
| 11 | M&L for Cutting of existing road not exc 1.5 mtr in depth and not exceeding 0.45 mtr wide including black top sub base and WBM, well ramming in layers with watering after laying of GI pipe under road making good in all respect to match with the existing surface all as directed by E-in-charge.Note : GI Pipe shall be measured and paid seperately. |
| 12 | S&F in repairs cable straight through heat Shrinkable joint kit 70 to 95 Sqmm 3.5 core XLPE 1.1 KV LT Cable complete including necessary excavation and earth work all as specified and directed. |
| 13 | S&F in repairs cable straight through heat Shrinkable joint kit 120 to 300 Sqmm 3.5 core XLPE 1.1 KV LT Cable complete including necessary excavation and earth work all as specified and directed. |
| 14 | S&F in repairs cable end termination joint 95 to 180 Sqmm 3.5 core XLPE 1.1 KV LT Cable heat shrinkable complete including necessary excavation and earth work all as specified and directed. |
| 15 | M & L for replacement of earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earting etc as required 25x4 mm galvanised iron strip for replacing earth continuity conductor of LT panels /bus bar panels etc complete all as specified and directed.. |
| 16 | M&L for repairing coping of pole with Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in coping padestal to poles including provision of necessary form work finishing the exposed surface even and smooth in nominal mix cement morter complete all as specified. |
| 17 | M & L for replacement of Digital type 3 phase voltmeter of capcity 0-500 V with selector switch complete all as specified and directed. |
| 18 | M & L for replacement of Digital type 3 phase ammeter of capcity 0-300 A with selector switch and CTs complete all as specified and directed. |
| 19 | M & L for replacement of Neon indicator lamp RYB set of three complete all as specified and directed. |
| 20 | M & L for changing the locks / hinges and repairing of PCC foundation including refixing the doors of LT panels by welding and painting the outer surface of panel by applying two coat of synthetic enamel paint complete all as specified and directedNote :- PCC for foundation measured and piad separately |
| 21 | Disconnecting from circuit/bus bar LT and taking out cables for extension of loop/passing through pipe reconnection with circuit and tightening of connections complete all as specified and directed |
| 22 | S&F in replacement of existing unserviceable changeover any size & capacity with ON load changeover 4 pole 400 Amps front handle operated along with SS enclosure including minor additional/alternation as required at site for fixing and connecting up of changeover complete all as directed by Engr-in-Charge. |
| 23 | S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 400 Amps 36KA Thermal magnetic and Microprocessor release with thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc complete all as directed by Engr-in-Charge. |
| 24 | S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 250 Amps 36KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc complete all as directed by Engr-in-Charge |
| 25 | S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 160 Amps 36 KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc complete all as directed by Engr-in-Charge. |
| 26 | S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 125 Amps 16KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc complete all as directed by Engr-in-Charge. |
| 27 | S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 63 Amps 16KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc complete all as directed by Engr-in-Charge. |
| 28 | S&F in replacement of existing unserviceable changeover any size & capacity with On Load changeover 4 pole 125 Amps with side handle operated including minor additional/alternation as required at site for fixing and connecting up of changeover complete all as directed by Engr-in-Charge. |
| 29 | S&F in replacement for danger notice plate of 1.6 mm thick mild steel sheet,vitreous enamelled white with letters,figures and conventional skul and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved size 20x15 cm for LT 415 volt fixed for LT pole/sub stn complete all as specified . |
| 30 | M&L for replacement battery charger 12volt/24 volt 10 to 16 Amps incl replacing the step down transformer ,connectors, control knobs , connecting wires complete all as specified and directed. |
| 31 | M&L for writing SM/MES number of DG set/Pump set and other equipements installed at installation using synthetic enamel writing paint of incl surface preparation complete all as specified and directed. Note: Size of each letter shall be of 6 cm x 6cm |
| 32 | M&L for Glow sign board of size not less than 90 cm x 60 cm x 30 cm size made out of angle iron frame 40mmx40mm covered with aluminuum sheet 18 SWG all side and acrylic sheet on front side duly printing the letters/emblom as directed by Engineer in Charge incl 02 nos LED fitting 2 feet 10 watts with necessary wiring complete including GI pipe 40 mm medium grade 2.2 mtr x 2 for supporting incl necessary excvation, PCC complete all as specified and directed at site . Note : Letters, font size and emblom shall be printed as per given format as diretcted by Engineer in Charge |
| 33 | S&F in replacement of GI tubing 40 mm dia light grade galvanised with all fittting laid on wall ceiling or in floors complete all as specified and direceted at site . |
| 34 | Supply & fixing in replacement , testing and commissioning of feeder pillar box ,out door type cubical shape,three phase, 4 wire, Cupper bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery ,busbar 400 Amps ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc (a) On load Change over switch 250 Amps 4 Pole- 01 Nos (b) Incomming :- MCCB 4 pole, 415 volts of capacity 200 Amp, 36 KA, with Thermal Magnetic Release - 01 No(c) Outgoing :- MCCB 4 pole, 415 volts of capacity 100 Amp, 25 KA, with Thermal Magnetic Release - 02 Nos(d) Outgoing MCB SPN 16 Amp 10KA -2Nos(e)Outgoing MCB TPN 16 Amp 10 KA 415 V -05 nos(e) Aluminium bus bar strips with proper colour code -04 Nos 400A with appropriate , incl insulator, nuts bolts etc complete .( f ) Voltmeter,digital type 0- 500 volt,with selector switch - 01 set (g) Ammeter Dital type 0-200Amps, with selector switch and CT'-1set ( h ) Phase indicating lamps LED type ( red , yellow, blue) -- 01 setNote:- Drg of bus bar junction box panel shall got approved by GE before execution at site. |
| 35 | Supply & fixing in replacing, install testing and commissioning of feeder pillar box ,out door type cubical shape,three phase, 4 wire, Cupper bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly ,and of suitable size to accomodate the items mentioned below and having seperate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs ,voltmeter,Ammeter and cable lugs etc (a) Incomming :- MCCB 4 pole, 415 volts of capacity 250 Amp, 36 KA, with Thermal Magnetic Release - 01 No(b) Outgoing :- MCCB 4 pole, 415 volts of capacity 100 Amp, 25 KA, with Thermal Magnetic Release - 03 Nos(c) Outgoing MCB SPN 16 Amp 10KA -1Nos(d)Outgoing MCB TPN 40 Amp 10 KA 415 V -02 nos(e) Aluminum bus bar strips 400 Amps with proper colour code -04 Nos 400A with appropriate , incl insulator, nuts bolts etc complete .( f ) Voltmeter,digital type 0- 500 volt,with selector switch - 01 set (g) Ammeter Dital type 0-200Amps, with selector switch and CT'-1set ( h ) Phase indicating lamps LED type ( red , yellow, blue) -- 01 setNote:- Drg of bus bar junction box panel shall got approved by GE before execution at site. |
| 36 | Supply & fixing in repair/ replacement install , testing and commissioning of Bus bar junction box panel outdoor kiosk type factory made of angle iron 65mmx 65mmx 6mm on all side welded to 3.15 mm thick CRCA sheet steel for outer compartment and 2.0 mm thick for inner compartment with openable shutteron both sides ( front and rear) , having locking arrangement totally enclosed weather proof outdoor spray painted internally and externally with two coats of synthetic enamel paint over a coat of primer suitable for 440 volts, 3 phase, 4 wire, 50 Hz with Aluminium bas bar of capacity 400 Amps AC supply, electrically connected as per norms and fitted with following accessories all as specified and directed by the Engr-in Charge. (Note:- Bus bar junction box shall be mounted on PCC 1:2:4 type B-1 with 20 mm graded stone aggregate foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item) . Note:- Drg of bus bar junction box panel shall got approved by GE before execution at site. INCOMMERIncoming MCCB, 415V, 4 pole, 250 Amps, 36 KA, Ics =100% Icu -01 nosIndicator Lamp-01 Set (Set of three) |
| 37 | Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25X4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009.00 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified. |
| 38 | Deduct Credit for Demolished/Dismantled material Rs (-) 90,921.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule)Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'. Please Enable Macros to View BoQ information |