| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, laying of cables, walls, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc. 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling in soft/loose soil including spreading, leveling and watering well ramming in layers n.exc. 25cm all specified and directed. |
| 3 | Removing excavated materials not exc 50 mtr and deposited where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and as directed. |
| 4 | Surface excavation n exc 30cm deep and average 15cm deep and getting out in soft/loose soil all as specified and directed. |
| 5 | M&L for PCC (1:5:10) type E-2, using 40mm graded stone aggregate in foundation, filing and mass concrete complete all as specified and directed. |
| 6 | M&L for PCC (1:4:8) type D-2, using 40mm graded stone aggregate in foundation, filing and mass concrete complete all as specified and directed. |
| 7 | M&L for 50mm thick red sand stone slabs in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified and as directed. |
| 8 | M&L for cutting grooves in brick wall, 75mm wide and 65mm deep for fixing joist, angle, channel section and sand stone slab in chajjas upto G+2 floor and finishing face of groove with cement mortar 1:3 complete all as specified and as directed. |
| 9 | M&L for Reinforced cement concrete (nominal mix) (1:2:4) type B1 using 20mm graded stone aggregate as in foundations, including rafts, footings, foundations beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed. |
| 10 | M&L for reinforced cement concrete (nominal mix) (1:2:4) type B1, using 20mm graded stone aggregate for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and other similar works complete all as specified and directed and directed. |
| 11 | M&L for reinforced cement concrete (nominal mix) (1:2:4) type B1, using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 12 | M&L for reinforced cement concrete (nominal mix) (1:2:4) type B1, using 20mm graded stone aggregate as in chajjas etc complete all as specified and directed. |
| 13 | Formwork to sides of concrete foundations footings bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter for rough finished of flat surface complete all as specified and directed. |
| 14 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished of flat surface complete all as specified and directed. |
| 15 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc. for rough finished surface of concrete complete all as specified and directed. |
| 16 | Formwork to sides of pillers, posts, struts, piers, columns and stanchions of square, rectangular or polygonal for rough finished surface of concrete complete all as specified and directed. |
| 17 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 18 | M&L for TMT MS bars of 5mm dia and upto 10mm dia as in stirrups and spacers cut to lengh bent to shape reqd incl cranking bending spirally for hooking for column and binding with MS annealed wire not less than 0.9mm dia complete all as specified and directed. |
| 19 | M&L for water proofing treatment with APP modified bituminous membrane 3mm thick consisting of the following for RCC roof :-(a) Cleaning palstered roof surfaces and applying a coat of oxidised bitumen based solvented primer a@ 0.3Kg /Sqm of approved make on top of dry surface of RCC roof complete all as specified and directed.(b) M&L for APP modified polymeric water proofing membrance 3mm thick weight not less than 3.0 Kg/Sqm with non woven polyster core of approved make applied by heating one surface of membrane with LPG torch with lap of 100mm and the overlap shall be sealed by flame complete all as specified and directed. |
| 20 | M&L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed. |
| 21 | S&F precast hydraulically pressed PCC tiles of size 25cm x 25cm x 20mm thick laid over and including screed bed 15mm thick in CM (1:4) set and jointed in neat cement slurry and pointed in CM (1:3) mixed with WPC of approved make in screed bed and pointing on roof complete height upto G+2 story bldg all as specified and directed. |
| 22 | M&L for 75 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 23 | M&L for 100 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 24 | M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate ) as in levelling of floor complete all as specified and directed. |
| 25 | M&L Non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match with and including 15mm thick screed bed in cement mortar (1:6) for laying floor finishes complete all as specified and as directed. |
| 26 | M&L for glazed ceramic tiles (coloured) 450mm x 300mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge. |
| 27 | Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-charge. |
| 28 | Roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove dust etc complete all as specified and directed. |
| 29 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge. |
| 30 | All as per item No 29.00 (here-in-before) abvoe but as in skirting over 10mm thick backing coat in CM (1:3) complete all as specified and directed. |
| 31 | M&L for machine cut Kota stone slab flooring 20 to 25mm thick (minimum size 550mm x 550mm or size as directed) laid over & including screed bed or bedding layer of 20mm thick in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge. |
| 32 | M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including cement plaster 15 mm thick in CM (1:3) laid and jointed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed. |
| 33 | M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge. |
| 34 | M&L for brick work with sub class ‘B’ old size burnt bricks straight or curved on plan to any radius half brick thick wall built in CM (1: 6) complete all as specified and directed. |
| 35 | Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc. complete all as specified and as directed. |
| 36 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed. |
| 37 | M&L for rendering 15 mm thick in CM 1:4 including water proofing compound on fair face of brick or concrete surface, finished even and fair without using extra cement complete all as specified and directed.Note:- WPC shall be measured and paid saperately. |
| 38 | Supply only liquid water proofing compound ISI marked complete all as specified and directed by Engineer-in-charge |
| 39 | M&L for rendering 5mm thick in CM (1:3) as on ceiling complete all as specified and directed. |
| 40 | M&L for preparing newly plastered surfaces and applying applying two coats of distemper with distemper oil emulsion white or tinted over and including one coat of 1mm thick wall care putty complete all as specified and directed. |
| 41 | M&L for preparartion of new plastered surfaces of walls and applying two coats cement base paint on walls complete all as specified and directed. |
| 42 | M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 43 | M&L for complete removal of existing treatment and preparation of old surface of walls and applying two coat of distemper oil emulsion distemper on wall incl applying a coat of wall care putty to achieve smooth finish to wall etc complete all as specified and directed. |
| 44 | M&L for complete removal and preparation of old painted surfaces of wall and applying two coat of exterior emulsion paint complete all as specified and directed. |
| 45 | M&L for preparation of old decorated, plastered or pointed surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying one coat of white wash complete all as specified & directed by Engineer-in-Charge. |
| 46 | S&F Factory made box type steel windows with hung shutters both glazed and guaged shutter frame 60x25 mm ERW hollow 'P' section with wall thickness not less than 1mm fixed to pressed steel frame 120mm x 70 mm x 1.6mm thick including fixing glazed portion, iron grills 8mm square MS bar hunges with steel handle and fitting, lugs etc, including one shop coat of primer complete all as specified and directed. |
| 47 | M&L 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing / new surfaces, complete all as specified and as directed. |
| 48 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge. |
| 49 | S&F Pressed steel frame for doors of size 105 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed. |
| 50 | S&F Pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed. |
| 51 | M&L for cement concrete type C-1, (1:3:6) using 20mm graded aggregate as in bed block or filling of chowkhats including necessary form work complete all as specified and directed. |
| 52 | M&L 35mm thick factory made glazed and skeleton shutters of 2nd class HW with partially panel shutter open rebated and prepared to receive glass / gauze etc edges or framing plain chamfered or rounded fitted with cut or mitred beads for securing glass etc as specified in SSR Part-1 section 8.24 (a) complete all as specified and directed. |
| 53 | Supply and fixing factory made plain framed, paneled shutter of 35 mm thick (two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using 2nd class Hard Wood (Hollock or Bonsum) rail and styles complete all as specified. |
| 54 | S&F 200 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge. |
| 55 | S&F 300 mm aluminium alloy, anodised sliding door bolts with hasp, staple and fixing clips of sheet, cast or extructed section and fixing bollts and sliding bolts of extruded section or cast aluminium ally and fixed complete all as specified and directed. |
| 56 | S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified & shown in relevant drawing of item No. 08095 in MES Schedule (Part-II) and directed by Engineer-in-Charge. |
| 57 | S&F 30mm thick factory made solid PVC moulded door shutter with particle board core with 5mm thick PVC moulded sheet on the front face and 5 mm thick PVC plain colour sheet on back face complete all as specified and directed by Eng-in-charge. |
| 58 | S&F Aluminium handles cast type anodised of size 125mm size, complete all as specified and directed. |
| 59 | S&F 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge. |
| 60 | S&F 100mm long stainless steel Butt hinges fixed complete all as specified and directed. |
| 61 | S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 62 | S&F 300mm mild steel (Helical door spring) ordinary rat tail rod pattrern spring including roller and roller plate complete with necessary welding work complete all as specified and directed. |
| 63 | S&F curtain rod, stainless steel of 25mm dia with fixing brackets stop rollers etc fix complete all as specified and directed. |
| 64 | M&L for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge. |
| 65 | M&L for preparation of new untreated steel and iron surfaces of any description, not exc. 10 cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge. |
| 66 | S & F 605X605 mm size of grid GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended form soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section ( not exc 1.2 m length ) of 0.55 mm thickness having kurled web of 50 mm and Cont/- |
| 67 | Cont/-flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including Hangers 6 mm dia. GI (up to 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40X 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia. 40 mm long etc complete all as spd and as directed. Incl providing and fixing non asbestos coloured designer board 4 mm thick in ceiling fixed with screw as per manufacturer's instructions complete all as specified and directed by Engineer-in-charge. |
| 68 | S&F steel work in tubular trusses including columns, special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS.1161-1998 grade St-240 complete all as specified and directed. |
| 69 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of colour as approved by GE and having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws at a height of approx 10 m all as specified. |
| 70 | S&F 15 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge |
| 71 | S&F 20 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge |
| 72 | S & F rotational moulded polyethylene water storage tank 750 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position with all necessary GI fittings complete all as specified in SSR Pt I complete all as specified and directed by Eng-in-charge. |
| 73 | S&F 20mm dia PTMT ball PVC valve, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-charge. |
| 74 | S&F vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device and jet spray complete all as specified & as directed by Engineer-in-charge. |
| 75 | S&F vitreous china squatting pan Orissa pattern, white of size 580x440mm with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, PCC filling and connection to trap and flushing pipe, antisyphonage pipe etc complete all as specified and directed by Engineer-in-charge. |
| 76 | S&F CP Jet spray butter fly design fixed on EWC with stanless screw as approve complete all as specified and directed by Eng-in-charge. |
| 77 | S&F CP Health faucet with stand fixed on wall in CP hose pipe 1 mtr length and stainless steel screw as approve complete all as specified and directed by Eng-in-charge. |
| 78 | S&F vitreous China wash hand basin, white, flat back size 550 x 400mm including 15mm dia, 450 mm long HDPE PVC connection, 750 mm long 32mm bore HDPE waste down pipe including CI brackets complete all as specified and directed. |
| 79 | S&F 600mm x 450mm beveled edge looking mirror of selected quality glass not less than 5.5mm thick, mounted on 6mm thick commercial plywood including PVC moulded framing and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engineer-in-charge. |
| 80 | S&F vitreous china urinal Half stall type, white incl CP spreader screwed for iron pipe and fixed complete including providing and fixing plugs with and including 60mm long brass screws, pointed around urinal back in cement, fixing discharge pipr, flush pipe, grating and union for discharge complete all as specified and directed by Engineer-in-charge. |
| 81 | S&F 10 litre capacity PVC valveless symphonic action type low level flushing cistern (ISI marked) including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified and directed by Engineer-in-charge. |
| 82 | S&F brass chromium plated towel ring round with round flange fixed to plug with chromium plated brass screws including wooden or plastic cleat complete all as specified and directed by Engineer-in-Charge. |
| 83 | S&F chromium plated Soap dish holder including chromium plated brass screws and plastic cleats complete all as specified & directed by Engineer-in-Charge. |
| 84 | S&F 15mm dia stop cock cast copper alloy, fancy type with, chromium plated long shank and cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge. |
| 85 | S&F 15mm bore CP angle valve, fancy type, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge. |
| 86 | S&F 2 way 15mm CP angle fancy type 15 mm bore high pressure screwed for iron pipe complete all as specified and directed by Engineer-in-charge. |
| 87 | S&F 450mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge. |
| 88 | S&F 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge. |
| 89 | S&F 15mm bore brass chromium plated basin mixer for mixing hot & cold water screwed down for iron pipe of 15mm bore complete all as specified and directed by Engineer-in-charge. |
| 90 | S&F pillar taps (fancy type), of 15 mm dia, cast copper alloy, with capstan heads, with chromium plated, screwed down high pressure with or without lettered 'hot' or cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed. |
| 91 | S & f grating round 125 mm size of PTMT (Minimum weight 50gms) complete all as specified. |
| 92 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or fixed in wall complete all as specified and directed. |
| 93 | S&F 75mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or fixed in wall complete all as specified and directed. |
| 94 | S&F PVC (SWR) 110mm bore bends any radius complete all as specified and directed. |
| 95 | S&F PVC (SWR) floor trap 75mm dia outlet plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as specified and directed. |
| 96 | S&F 110mm PVC (SWR) vent cowl complete all as specified and as directed. |
| 97 | S&F 75mm bore PVC (SWR) junction, single (single T) equal or unequal complete all as specified and directed by Engineer-in-Charge. |
| 98 | S&F 110mm bore PVC (SWR) junction, single (single T) equal or unequal complete all as specified and directed by Engineer-in-Charge. |
| 99 | M&L hard core of guage not exc. 63mm deposited spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed. |
| 100 | M&L for sand filling under floors or in foundation complete all as specified and directed. |
| 101 | M&L for Machine pressed precast conctete interlocking paver block with grey cement & pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed. |
| 102 | M&L for cement concrete (1:2:4) type B2 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railigs upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, sligtly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed. |
| 103 | M&L for cement concrete (1:3:6) type C-1, using 20 mm graded stone aggregate as in surface channels or drain complete all as specified and directed. |
| 104 | M&L cement concrete 1:3:6 mix type C2 (using 40mm graded stone aggregate) as in bed to drain pipe including packing under and hunching against the sides of pipes after laying in trenches to required slope and tested complete all as specified for 150 mm bore pipe complete all as specified and directed by Engineer-in-Charge. Note :- Thickness of concrete bed below the barrel of pipe shall be 10 cm and width of bed shall be outer dia of pipe plus 30 cm. |
| 105 | M&L for Reinforced concrete pipes, class NP2, laid and jointed complete with collars with bore of pipe 150mm laid in trenches and jointed in CM (1:1) complete all as specified and directed. |
| 106 | M&L Precast Cement Conctete 1:2:4 type B1, using 20mm graded stone aggregate as in cover slabs for man holes etc set in cement morter 1:6 including necessary form work complete all as specified and directed. |
| 107 | Material and labour for 2.00 metre dia and 3.00 metre depth soakage well for 50 users, including necessary excavation in any type of soil, plain cement concrete 1:3:6 in foundation, honey combing masonry wall, with top ring of M-25 design mix concrete, intercepting chamber and screen chamber made of brick masonry in cement mortar 1:6, RCC precast cover slab in M-25 cover, interconnecting pipes of RCC/SGSW, filled with brick bats etc complete all as specified and as directed.Ref Drg No CEJZ/TD/521 Sheet No 1/2 & 2/2. |
| 108 | Material and labour for 5.00 metre length, 2.00 metre width and 1.75 metre depth septic tank for 50 users, including necessary excavation in any type of soil, plain cement concrete 1:3:6 in foundation, masonry wall, with top RCC slab of M-25 design mix concrete including necessary formwork, intercepting chamber and screen chamber made of brick masonry in cement mortar 1:6, RCC precast cover slab in M-25 cover, interconnecting pipes of RCC/SGSW, filled with brick bats etc. including 100 mm dia CI vent pipe 3m long, complete all as specified and as directed.Ref Drg No CEJZ/2002/TD/S-2 Sheet No 1/1. |
| 109 | Material and labour for 2.66 metre length, 1.20 metre width and 2.25 metre depth septic tank for 25 users, including necessary excavation in any type of soil, plain cement concrete 1:3:6 in foundation, masonry wall, with top RCC slab of M-25 design mix concrete including necessary formwork, intercepting chamber and screen chamber made of brick masonry in cement mortar 1:6, RCC precast cover slab in M-25 cover, interconnecting pipes of RCC/SGSW, filled with brick bats etc. including 100 mm dia CI vent pipe 3m long, complete all as specified and as directed.Ref Drg No CEJZ/2002/TD/S-2 Sheet No 1/1. |
| 110 | Material and labour for 1.80 metre dia and 3.00 metre depth soakage well for 25 users, including necessary excavation in any type of soil, plain cement concrete 1:3:6 in foundation, honey combing masonry wall, with top ring of M-25 design mix concrete, intercepting chamber and screen chamber made of brick masonry in cement mortar 1:6, RCC precast cover slab in M-25 cover, interconnecting pipes of RCC/SGSW, filled with brick bats etc complete all as specified and as directed.Ref Drg No CEJZ/2004/TD/S-35 Sheet No 1/1. |
| 111 | M&L for Point wiring complete with 1.5 sqmm single core FRLSH PVC insulated cable with multi stranded copper condutor in and including PVC conduit 20mm dia and thickness not less than 1.5mm, ISI marked with all accessories for surface or concealed conduit as directed at site incl chase cutting for one light/fan point controlled by one one way switch including MS sheet sunken box concealed on wall duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint with 3mm thick hylum brand bakelite sheet cover for fixing switches, sockets, regulators etc. alongwith 1.5 sqmm multi stranded FRLSH, PVC insulated copper cable as continuous earth connected to common earth and earth dolly including making good the disturbed surfaces complete all as specified and as directed. |
| 112 | All as per serial item No. 110.00 here-in-before but for One 3 pin 5 Amp socket outlet on independent board. |
| 113 | All as per serial item No. 110.00 here-in-before but for One 5 pin 5 Amp socket outlet on the same board with other switches. |
| 114 | M&L for point wiring with 2.5 sqmm PVC insulated, unsheathed FRLSH multistrand copper conductor cable 1100 volts grade drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all and including conduit fittings and fixing accessories 1.2mm thick sunken anodised pressed steel terminal boxes with 3.0 mm thick hylam sheet cover for mounting switches, socket etc including 2.5 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire complete for one socket 16 Amp socket outlet controlled by one switch on independent board.complete all as specified and directed. |
| 115 | M & L concealed sub main wiring with 2 runs of 4 sqmm main wire along with 1 run of 4 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same complete all as specified by Engr- in- Charge.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. |
| 116 | M & L concealed sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same complete all as specified by Engr- in- Charge.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. |
| 117 | S & F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with finger proof terminal complete all as specified and directed. |
| 118 | S & F modular type 2/3 pin 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 119 | S & F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. |
| 120 | S & F modular type 2/3 pin 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 121 | S & F modular type 3/5 pin socket with one Single pole MCB 20 Amp 230 volt including concealing in wall suitable for AC and domestic appliances complete all as specified and directed. |
| 122 | S & F modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed. |
| 123 | S&F Angle / batten holder polycorbonate type body suitable for batten fitting complete all as specified and directed. |
| 124 | S&F LED bulb of capacity 10/12 watts not less than 700 lumens output at 6500K colour temp, complete all as specified and directed. |
| 125 | S&F ceiling rose 63x30 mm three terminal, polycorbonate body complete all as specified and directed. |
| 126 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 127 | S&F LED (1.2m) smartbrite extra batten made of CRCA sheet housing provided for efficient heat dissipation with a PC glossy diffuser duly prewired connection having a normal system lumen output of 2000 lumen/20 watt at a minimum system efficacy of 2000 lumen per 20 watt and total power consumption not more than 20 watt including driver of capacity 10 KA. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10\\"%\\" AND PF>0.95 complete all as specified and directed. |
| 128 | S&F LED (0.6m) smartbrite extra batten made of CRCA sheet housing provided for efficient heat dissipation with a PC glossy diffuser duly prewired connection having a normal system lumen output of 1150 lumen/10 watt at a minimum system efficacy of 1150 lumen per 10 watt and total power consumption not more than 10 watt including driver of capacity 5 KA. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10\\"%\\" AND PF>0.95 complete all as specified and directed. |
| 129 | Supply & fixing security light with LED street light, 35 Watt, IP - 66, Impact resistance - IK07, colour temp- 5700 K, Class-I in pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, separate optical and control gear compartment & top opening for easy maintenance. Polyster powder coated grey after phosphochromate treatment High efficiency long life LED modules with SMD LED package mounted on MCPCB. Lumen efficacy of LED >110 lm/W with PC lens to ensure better uniformity of light distribution. Powered by Built-in, Potted electronic LED driver (SMPS based constant current supply) with lower THD, Output Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13 alongwith arm with single arm bracket OD 58 mm (max) with clamp, nut, bolts etc mounted on wall complete in all respect complete all as specified and directed. |
| 130 | Supply & fixing sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 131 | Supply & fixing sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. |
| 132 | Supply & fixing of MCB single pole 240 volt any rating from 6 to 32 amps, C series with rupturing capacity 10 KA complete all as specified and directed. |
| 133 | Supply & fixing of MCB Single Pole Neutral 240 volt any rating from 32 to 63 amps, C series with rupturing capacity 10 KA complete all as specified and directed. |
| 134 | Supply, installation, testing & commissioning of electric storage water heater of 25 litre capacity, rated voltage 230 Volt, single phase, 50 Hz of rated power input-2000 Watt conforming to IS 2082 with standing loss ≤ 0.511 & ≥ 0.465 KWh/24Hr/45°C (5 Star BEE rating wef 01 Jan 2024) having dry powder coating in water stoarge tank of ultra thick super cold rolled steel plates of high-strength, sock proof ABS body using IPX4 technology to protect electrical parts from water to avoid direct contact between cold and hot water flow, glass coated incoloy heating element for good corrosion resistance with execllent resistance to both oxidation and carbonization, panel for temperature setting between 25°C to 75°C to control energy consumption, with 3 preset controls for easy operation, energy saving high density thick PUF insulation for better heatCont/- |
| 135 | Cont/-reterition, having sacrificial magnesium anode rod with steel core to protect water tank from rust and corrosion to enhance the tank life, having safety feature like thermostate, thermal cut off, multifunction valve, shock-safe plug to prevent electric shocks by cutting off the power in case of current leakage suitable for high-rise buildings of 8 bar (0.8 Mpa) pressure including fixing & connecting accessories like mild steel anchor fastener of size 10 x 100mm with nuts and washers, drilling/making hole on wall with provision of stainless steel breaded (SS 304 Graded) connection pipe (01 Pair) in 600 mm long or as per site long enough to connected angle valve for hot & cold water circulation with nuts and washers and testing and including 15 mm bore CP angle valve of approved make and painting MES No. on geyser all as specified and and directed. |
| 136 | S&F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230 V, 5 Hz, RPM 1200, copper winding of sweep 300mm complete all as specified and directed. |
| 137 | Supply and fixing Exhaust fan metallic body of size 300 mm sweep, 50 Hz, AC 240Volt, 900 RPM, dynamically balanced impellers for smooth & vibration free operation, pre-lubricated double ball bearing for maintenance free running with aerodynamically designed & balanced blade, air delivery 1275 Cum/hr, noise level 40dB- 45dB and power consumption (50 W±10%) heavy duty single phase supply including mild steel louvers all as specified and directed. |
| 138 | Supply and fixing of burnt conventional fans with BLDC ceiling fans, 5 star rated by Bureau of energy with service value of not less than 6.00, (26W±10%) with or without remote, with rated speed 350 Rev per min, air delivery 220 Cum/min complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200 mm sweep, suitable for single phase supply complete all as specified and directed. |
| 139 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt, connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel protected by galvanised iron light grade 15 mm dia pipe and GI pipe 20mm light grade for water filling including 15x20mm reducer socket funnel wire mesh, RCC cover with concrete 1:2:4 using 8 mm# bar@100 mm c/c both ways ,PCC chamber pit with PCC (1:3:6) type C-2 and excavation and earth work,disposal of suplus spoil to a dstance not exceeding 50mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) complete all as specified and directed. Note :- The unit rate includes for protection pipe and GI wire 4mm dia from top of earth plate up to 7.5 meter above ground level. |
| 140 | S & F MCB DB VTPN with sheet metal enclosure MCB DB VTPN 4 way with 125 amps rated bus bar 415 volts double door with isolated Neutral Bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed. |
| 141 | Supply & fixing of MCCB - 63 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & fixed magnetic protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in DB complete all as specified and directed. |
| 142 | Supply & fixing of MCCB - 100 Amp, 415 Volt, 4 pole, 16 KA with adjustable thermal & fixed magnetic protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in DB complete all as specified and directed. |
| 143 | Supply & fixing of MCCB - 200 Amp, 415 Volt, 4 pole, 36 KA with adjustable thermal & magnetic setting/protection, Ics = 100% Icu, thermal adjustable - 0.8 to 1 In, magnetic adjustment - 5 to 10 In in accordance with IS/IEC 60068-2-6 standard including making connection, testing and commissioning in DB complete all as specified and directed. |
| 144 | S&F 20mm gun metal globe or gate valve conforming to IS : 778 ISI marked with iron wheel head screwed both ends for iron pipe including GI fitting socket, nipple, unions as well cutting of pipe and necessary earth work complete all as specified and directed. |
| 145 | M&L for sand cushioning and covering clean and dry sand to underground electric cable in trenches / floor complete all as specified and directed.Note :- Punned thickness shall be measured and paid for. |
| 146 | M&L for sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and directed. Please Enable Macros to View BoQ information |
| 147 | M&L for sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |