| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair /Maint to servo stabilizer, UPS/inverters and other EM equipment's at AOR of Command HQs and other locations under GE (Utilities) Udhampur Contract No: GE/U-21/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | M&L for dehydration & filtration of voltage stabilizer by dehydration plant (bringing plant at site) including testing of sample before and after dehydration and filtration to achieved 40 KV at 2.5 mm gap complete all as specified and directed by Engineer-in-Charge:-Note : (i) The filtration of the voltage stabilizer oil shall be carried out at different locations of GE (U) Udhampur(ii) The report before filtration & after filtration to be submitted by contractor .(iii) Oil for topping up will be measured and paid separately.(iv) Centrifuging Machine with all T&P & testing eqpt required for dehydration to be arranged by contractor. |
| 3 | Supply & toping up of new voltage stabilizer oil (in sealed barrel) conforming to IS 335 std having dielectric strength 40 KV at 2.5 mm gap after initial dehydration complete all as specified and directed by Engineer-in-ChargeMake : Savita/Castrol/Power True/Truoil. |
| 4 | M & L for rewinding 433 Volts LV coils of voltage stabilizer of using proper size super enameled copper wire suitable for working voltage 1.1 KV including three layer insulated material as per existing size of core including testing and commissioning complete all as specified and directed by Engineer-in-ChargeNOTE :-i). Oil filtration, supply of new oil will be measured separately.ii). All petty parts including nut, bolts, gasket minor weldings are deemed to be included the rate quoted.iii). The rate for taking out,refixing after repair, both side transportation, lifting /unloading of voltage stabilizer by crane /manual should be deemed to include in the rate quoted. |
| 5 | Supply and fixing in repair digital voltmeter, ranging from 0 to 500 Volts as per existing make and model, including providing necessary electrical connections (to accommodate in panel board) complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply and fixing in repair digital ammeter, ranging from 0 to 400 Amps (with CT of suitable ratio), as per existing make and model, including providing necessary electrical connections (to accommodate in panel board) complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply and fix in repairs Indicator Lamps (LED type) as per existing make and model, including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge. |
| 8 | Dismantling and taking out old worn out reversible synchronous motor from the voltage stabilizer and supply and fix reversible servo motor (3 Kgs.) with RC, single phase 230 Volts as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 9 | Dismantling and taking out old worn out reversible synchronous motor from the voltage stabilizer and supply and fix reversible servo motor (10 Kgs.) with RC, single phase 230 Volts as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 10 | Dismantling and taking out old worn out reversible synchronous motor from the voltage stabilizer and supply and fix reversible servo motor (20 Kgs.) with RC, single phase 230 Volts as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply and fix in replacement of Transformer suitable for 20 to 50 KVA Servo voltage stabilizer as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply and fix in replacement of Transformer suitable for 60/63 KVA Servo voltage stabilizer as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply and fix in replacement of Transformer suitable for 100 KVA Servo voltage stabilizer as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply and fix in replacement of Transformer suitable for 200 KVA Servo voltage stabilizer as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply and fix in replacement of Transformer suitable for 300/400 KVA Servo voltage stabilizer as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply and fix in replacement of Dimmer suitable for 20 to 60 KVA Servo voltage stabilizer as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and fix in replacement of Dimmer suitable for 100 KVA Servo voltage stabilizer as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply and fix in replacement of Dimmer suitable for 120 to 200 KVA Servo voltage stabilizer as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply and fix in replacement of Dimmer suitable for 250 to 400 KVA Servo voltage stabilizer as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 20 | Dismantling and taking out old worn out Push Button/ Auto manual switch/Micro Switch/ Potentio Meter/ Limit Switch/ Lever Switch from the voltage stabilizer and supply and fix new Push Button/ Auto manual switch/Micro Switch/ Potentio Meter/ Limit Switch/ Lever Switch suitable for voltage stabilizer capacity up to 400 KVA and testing as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 21 | Dismantling and taking out old worn out Trigger Transformer 9V/18V from the voltage stabilizer and supply and fix new Trigger Transformer 9V/18V suitable for voltage stabilizer capacity up to 400 KVA complete all as specified and directed by Engineer-in-Charge. |
| 22 | Dismantling and taking out old worn out servo control panel from the voltage stabilizer and supply and fix new Servo Control panel suitable for voltage stabilizer capacity up to 400 KVA as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 23 | Dismantling and taking out old worn out servo control box from the voltage stabilizer and supply and fix new Servo Control Box suitable for voltage stabilizer capacity up to 400 KVA as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 24 | Dismantling and taking out defected PCB from the voltage stabilizer and supply and fix new Servo circuit card (PCB) suitable for voltage stabilizer capacity up to 400 KVA as per existing make and model ccomplete all as specified and directed by Engineer-in-Charge at site. |
| 25 | Supply and fix in repairs carbon brush of voltage stabilizer of capacity up to 400 KVA complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for spray painting of servo voltage stabilizer/isolation Transformer, preparation of old painted surfaces of steel body by brushing/cleaning stain, greasy spots with thinner outside of voltage stabilizer/Isolation transformer indoor/outdoor type capacity 10 KVA to 30 KVA to match with existing colour complete all as specified and directed by Engineer-in-Charge. |
| 27 | Description all as per ser item No 25.00 here-in-before, but capacity of 50 KVA to 100 KVA. |
| 28 | Description all as per ser item No 25.00 here-in-before, but capacity of 200 KVA to 400 KVA. |
| 29 | Supply and fix in repair top cover gasket/cock sheet suitable for 10 KVA to 50 KVA Voltage Stabilizer/Isolation transformer complete all as specified and directed by Engineer-in-Charge at site. |
| 30 | Description all as per ser item No 28.00 here-in-before, but capacity of 60/63 KVA to 160 KVA |
| 31 | Description all as per ser item No 28.00 here-in-before, but capacity of 200 KVA to 400 KVA |
| 32 | S & F in repairs control wiring of voltage stabilizer of capacity up to 400 KVA complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fix in repairs high low voltage cut off circuit of voltage stabilizer as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 34 | Routine periodical maintenance/servicing as and when required and testing of voltage stabilizer/Isolation Transformer of capacity up to 400 KVA complete including all consumables items like cotton, waste cloth, kerosene oil etc.Maintenance will be carried out as complete all as specified and directed by Engineer-in-Charge and comprising of the following :-(a) Greasing of all points.(b) Checking of servo(c) Checking of relays, selector switch, control switch, micro switch, carbon brush.(d) Checking of sensing trigger transformer, main transformer and dimmer.(e) Checking of ammeter, voltmeter contactor.(f) Checking and repairing of all internal wiring and connection of voltage stabilizer complete.(g) Checking of any leakage of oil.h) Repair/rewiring of broken/damaged control panel connection including measuring instruments, indicators, etc. |
| 35 | Routine periodical maintenance/servicing as and when required and testing of UPS 5 KVA to 30 KVA capacity single phase/ three phase complete including all consumables items like cotton, waste cloth, kerosene oil etc.Maintenance will be carried out as complete all as specified and directed by Engineer-in-Charge and comprising of the following :-(a) Cleaning all parts and card.(b) Cleaning cooling fan.(c) Top up battery distil water |
| 36 | Supply and fix inreplacement of Batteries (VRLA / Li-ion / Tubular, depending on model) of capacity (12V, 50Ah–100 Ah) as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply and fix in replacement of Batteries (VRLA / Li-ion / Tubular, depending on model) of capacity 12 Volt 180/200Ah as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and fix in replacement of Battery fuses / battery breaker (DC MCB/MCCB) suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and fix in replacement of Battery connectors, links, and cables suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply and fix in replacement of IGBT modules (in inverter & rectifier sections) suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply and fix in replacement of Power diodes / rectifier bridges suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply and fix in replacement of Snubber circuits (resistor + capacitor assemblies) suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 43 | Supply and fix in replacement of DC bus capacitors (electrolytic, high voltage) suitable for 15 to 30 KVA UPS UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply and fix in replacement of inverter driver boards / gate driver cards suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply and fix in replacement of Control PCB / DSP board (system logic) suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply and fix in replacement of input & output contactors / relays suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 47 | Supply and fix in replacement of Static switch module (SCRs / Triacs) suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply and fix in replacement of input & output MCBs / MCCBs suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply and fix in replacement of Surge protection devices (SPDs) suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supply and fix in replacement of Current transformers (CTs) & voltage sensors suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 51 | Supply and fix in replacement of Cooling fans / blowers suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 52 | Supply and fix in replacement of Air filters suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 53 | Supply and fix in replacement of Heat sink compound / thermal pads suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 54 | Supply and fix in replacement of LCD / HMI display unit suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 55 | Supply and fix in replacement of Communication cards (SNMP, Modbus, RS-485, etc.) suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 56 | Supply and fix in replacement of Control fuses (low-rating, PCB type) suitable for 15 to 30 KVA UPS UPS as per existing make and model ccomplete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply and fix in replacement of Cables and connectors (signal & power) suitable for 15 to 30 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply and fix in replacement of Battery fuses / battery breaker (DC MCB/MCCB) suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply and fix in replacement of Battery connectors, links, and cables suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fix in replacement of IGBT modules (in inverter & rectifier sections) suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply and fix in replacement of Power diodes / rectifier bridges as per existing make and model suitable for 05 to 10 KVA UPS complete all as specified and directed by Engineer-in-Charge. |
| 62 | Supply and fix in replacement of Snubber circuits (resistor + capacitor assemblies) suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 63 | Supply and fix in replacement of DC bus capacitors (electrolytic, high voltage) suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 64 | Supply and fix in replacement of inverter driver boards / gate driver cards suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 65 | Supply and fix in replacement of Control PCB / DSP board (system logic) suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 66 | Supply and fix in replacement of input & output contactors / relays suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 67 | Supply and fix in replacement of Static switch module (SCRs / Triacs) suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 68 | Supply and fix in replacement of input & output MCBs / MCCBs suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 69 | Supply and fix in replacement of Surge protection devices (SPDs) suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 70 | Supply and fix in replacement of Current transformers (CTs) & voltage sensors suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 71 | Supply and fix in replacement of Cooling fans / blowers (fail quite often, need spares) suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 72 | Supply and fix in replacement of Air filters (if used) suitable for 05 to 10 KVA UPS as per existing make and model ccomplete all as specified and directed by Engineer-in-Charge. |
| 73 | Supply and fix in replacement of Heat sink compound / thermal pads suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 74 | Supply and fix in replacement of LCD / HMI display unit suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 75 | Supply and fix in replacement of Communication cards (SNMP, Modbus, RS-485, etc.) suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 76 | Supply and fix in replacement of Control fuses (low-rating, PCB type) suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 77 | Supply and fix in replacement of Cables and connectors (signal & power) suitable for 05 to 10 KVA UPS as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 78 | Attending breakdown for Servo Voltage stabilizer/ UPS detect fault related to breakdown by a service Engineer complete all as specified and directed by Engineer-in-Charge.Note:- (a) Spares will be measured and paid separately under relevant items.(b) The break down complaint should be attended within 8 hours by the intimation of Engr-in-charge or concern JE E/M by telephonically / verbally. (c) Not attended of complaint within eight hours will lead to recovery from subsequent payment in the following manner :- (i) Not attending within 0 to 8 Hours - Rs. 2000.00 (ii) Not attending within 8 to 16 Hours- Rs. 2000.00 (iii) Not attending within 16 to 24 Hours- Rs. 2000.00 (iv) Not attending after24 Hours - Rs. 5,000.00 (v) The maximum recovery will be Rs. 50,000.00 plus the expenditure incurred for rectification of the same by any other means. |
| 79 | Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.15 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd. with the following, complete all as specified and directed by Engineer-in-Charge:-(a) S & F copper bus bar 600 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conical type at a maximum interval of 500 mm- 01 Set.(b) S&F MCCB FP 400 Amps 35 KA - 01 No |
| 80 | Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.15 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd. with the following, complete all as specified and directed by Engineer-in-Charge:-(a) S & F copper bus bar 400 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conical type at a maximum interval of 500 mm- 01 Set.(b) S&F MCCB FP 250 Amps 35 KA - 01 No Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |