| 1 | M& L for Servicing of DG set by deputing OEM service representative to attend the DG set regularly to carrying out scheduled preventive maintenance checks on diesel generating set (of any Make and carryout the Starting system, Fuel injection system, Transmission system, generation system, Battery check up, Alternator check etc. check/works during the calender year all as directed by Engg-in-charge.Carry out maintenance/check as per maitenance schedule during every visit as per contract. Note 1 : All major spare parts costing above Rs. 500 will be measured & paid separately. Note 2 : Minor Spare parts costing upto Rs. 500 deemed to be included the rate quoted by the contractor for comprehensive/routine maint. Note 3 : Periodical testing register shall be maintained at site and produced to Engg-in- charge for sign on monthly basis. Note 4 : All Routine maintenance/testing shall be done through Specialist agency. |
| 2 | All as per item No.1.0 diesel engine driving generating set of capacity 250 KVA located at (Junior/ Senior Sailor Block, NSB) - 02 Nos |
| 3 | All as per item No.1.0 Diesel engine driving generating set of capacity 160 KVA, located at ( Auditorium INS SP, NCN and DCN INS SP) - 03 Nos & (NAE Hanger 314 and NAE Hanger 343) - 02 Nos |
| 4 | All as per item No.1.0 diesel engine driving generating set of capacity 125 KVA located at (Golf Course Nofra,TS INS Sardar patel, Comcen)- 03 Nos |
| 5 | All as per item No.1.0 Diesel engine driving generating set of capacity 100 KVA, located at (Logistic and Technical complex INS Sardar patel) - 02 Nos |
| 6 | All as per item No.1.0 diesel engine driving generating set of capacity 75 KVA located at (Pump House INS Sardar Patel and Ward room) - 02 Nos |
| 7 | All as per item No.1.0 Diesel engine driving generating set of capacity 62.5 KVA located at (Technical Storage Shed INS SP) - 01 No. |
| 8 | All as per item No.1.0 Diesel engine driving generating set of capacity 50 KVA located at (NAE MET Complex) - 01 No. |
| 9 | All as per item No.1.0 Diesel engine driving generating set of capacity 40 KVA located at (NAE Hanger 343 Trolley mounted) - 02 No. |
| 10 | All as per item No.1.0 diesel engine driving generating set of capacity 30 KVA located at (Navy House, Nofra) - 01 Nos |
| 11 | All as per item No.1.0 Diesel engine driving generating set of capacity 20 KVA, (located at MES Complex) |
| 12 | Note for Servicing items of the Schedule ITEM NO 1 |
| 13 | Note:- 1) The above Item Includes following a) Labour Charges tools/gauges for Major and Minor repairs including Overhauls b) Labour charges for all unlimited Breakdown Complaints related to Genset for a period of one year c) Preventive Maintenanace 4 visit in a Contract period to carry out Inspection of 61 Check points of DG sets |
| 14 | Note:- 2) The above Item excludes following a) Cost of consumables and spares parts require for preventive or breakdown Visits b) Charges for external job works lke FIP-Starter-Charging alternator repairing, AC Alternator Repairing, Machining required for any part of Genset. |
| 15 | Note :-3) The Spare Parts, engine Oil & Premix Coolant used for work under contract must be 'Greaves Lub Oil ' genuine / recommended by OEM Purchased from Authorised Greaves Cotton Ltd Service & Spare Dealership. |
| 16 | Note:-4) All works under contract must be carried out by Kirloskar/Greaves Cotton Ltd Trained Service Engineers from Local Autorised Greaves Cotton Ltd Service & Spare Dealership to have a quick /urgent hastle free service to restore the system in minimum time frame |
| 17 | Note:-5) The Minor Brakdown Complaints will be attended within 4 Hrs & should be rectified 24 Hrs by Trained Service Engineers from Local Autorised Service & Spare Dealership. |
| 18 | Note:-6) Contractor has to collabrate with \\"Kirlskar/Greaves Cotton Ltd\\" Service Package from Authorised Dealer of Kirloskar/Greaves Cotton Ltd after acceptance of contract |
| 19 | Supply and fix in repairs/replacement of following misc items capacities of 250 KVA DG Sets at NSB (02 Nos) :- |
| 20 | Fuel filter |
| 21 | Lub Oil filter |
| 22 | By pass oil filter |
| 23 | Air filter (inner and outer) |
| 24 | Fuel injector |
| 25 | Fuel connectors high pressure pipes |
| 26 | Radiator fan belt |
| 27 | Supply and fix in repairs/replacement of following misc items capacities of 125 KVA to 160 KVA DG Sets ( DG sets 08 Nos) :- |
| 28 | Fuel filter |
| 29 | Lub Oil filter |
| 30 | By pass oil filter |
| 31 | CR filter plate & 'O' ring |
| 32 | Air filter (inner and outer) |
| 33 | V belt |
| 34 | Radiator fan belt |
| 35 | Turbocharger Hose pipe |
| 36 | Emergency stop switch |
| 37 | Supply and fix in repairs/replacement of following misc items capacities of 62.5 KVA to 100 KVA DG Sets (05 Nos) :- |
| 38 | Fuel filter |
| 39 | Lub Oil filter |
| 40 | By pass oil filter |
| 41 | CR filter plate & 'O' ring |
| 42 | Air filter (inner and outer) |
| 43 | V belt |
| 44 | Radiator fan belt |
| 45 | Battery connectors with brass end |
| 46 | Supply and fix in repairs/replacement of following misc items capacities of 20 KVA to 50 KVA DG Sets (05 Nos) :- |
| 47 | Fuel filter |
| 48 | Lub Oil filter |
| 49 | By pass oil filter |
| 50 | CR filter plate & 'O' ring |
| 51 | Air filter (inner and outer) |
| 52 | V Belt |
| 53 | Radiator Fan Belt |
| 54 | Battery Connectors with brass end |
| 55 | Supply and fix in replacement Battery suitable for 12 Volts DC supply 180 AH, complete all as specified & directed by EIC Make AMARON/Exide or equivalent |
| 56 | Supply and fix in replacement Battery suitable for 12 Volts DC supply 120 AH, complete all as specified & directed by EIC Make AMARON/Exide or equivalent |
| 57 | M&L for dismantling existing unserviceable exhaust pipe of 50KVA/100KVA/125 KVA/160 KVA /250 KVA DG set and supply and fix new exhaust pipe of exiting model complete including lapping asbestos rope making good all disturbed surface area to match the surrounding |
| 58 | Material and labour for manual scraping of old painted surface and providing spray painting with two coat of synthetic enamelled paint of aquostic enclosure of following size of DG Sets complete all as specified and directed by Engr-in-charge. |
| 59 | 250 KVA |
| 60 | 125-160 KVA |
| 61 | 62.5-100 KVA |
| 62 | 20-50 KVA |
| 63 | Supply and topping up of lubricant oil of various capacity of DG sets at various location under GE Navy Porbandar complete all as specified and directed by Engr-in-charge. |
| 64 | Supply and topping up of Coolant of various capacity of DG sets at various location under GE Navy Porbandar complete all as specified and directed by Engr-in-charge. |
| 65 | M & L for servicing Fuel injection pump of 100 to160 KVA DG Set by striping off complete and cleaning each part in volatile liquid cleaner / petrol removing scales, cleaning, injector, spray nozzle including replacement of wornout parts such as injector heads including re-calibration from authorised service centre for smooth functioning etc. including testing and refixing in the same position all as specified and as directed by Engineer-In-Charge. |
| 66 | M&L for Complete repair/overhauling ,servicing of radiator ,cooling fan assembly , belts, bearings, cleaning of fins, leakage detection by high pressure fluid method and repair leakages in radiators incl replacement of complete repair kit required for the following capacities :- |
| 67 | 250 KVA |
| 68 | 125-160 KVA |
| 69 | 62.5-100 KVA |
| 70 | 20-50 KVA |
| 71 | S&F Battery Charger 230 V, AC Input and 24 Volt DC out put suitable for AMF panel as per exising make complete all as specified and directed by Engineer-In-Charge. |
| 72 | Supply and fix in replacement of defective automatic voltage rectifier of 30/ 75/125/160 KVA DG set complete all as directed. |
| 73 | M & L for complete servicing and rewinding of of Alternator of DG set upto 160 kVA capacity complete testing at site , Shifting to Workshop dismantling and refixing after rewinding and testing all as specified and as directed |
| 74 | S & F in repair/replacement of Power contactor current rating upto 225A fixed complete all as specified and as directed by the Engineer-In-Charge. Make L&T/C&S or equivalent |
| 75 | M & L for complete servicing of control panel of DG sets of any capacity , checking working of Display, Internal Circuits, ON-OFF system , Fuel indicators complete all as specified and as directed |
| 76 | M & L for Repair/Replacement of DG set control panel of 20-75 KVA capacity all as per standard OEM specification including removing unserviceable panel all as specified and as directed. |
| 77 | M & L for Repair/Replacement of DG set control panel upto 100-160 KVA capacity capacity all as per standard OEM specification including removing unserviceable panel all as specified and as directed. |
| 78 | M & L for Repair / Replacement of On load Change over switch panel of capacity 200 Amps manually operated with enclosure SS of 1.6 Guage thickness all as specified and directed Make :L&T or equivalent |
| 79 | M & L for Repair / Replacement of On load Change over switch panel of capacity 400 Amps manually operated with enclosure SS of 1.6 Guage thickness all as specified and directed Make :L&T or equivalent Please Enable Macros to View BoQ information |
| 80 | M & L for Repair / Replacement of On load Change over switch panel of capacity 400 Amps manually operated with enclosure SS of 1.6 Guage thickness all as specified and directed Make :L&T or equivalent Please Enable Macros to View BoQ information |