Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | \\" BOQ \\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Chief Engineer Shillong Zone NAME OF WORK: PROVISION OF SWIMMING POOL AT LICHUBARI UNDER GE JORHAT. Contract No: CESZ/JOR/ OF 2025-2026 Bidder Name : GENERAL SUMMARY (SCHEDULE OF WORKS) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # Sl.No. Description of Parts/ Item Item Code / Make No. orQty. Unit Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Figure TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 3 | SCHEDULE ‘A’ PART-I(A) (BUILDING &STRUCTURE WORKS)Construction of Swimming pool, Swimming pool shed and Spectator's Gallery, Plant room, Changing room, Balanching tank etc RCC framed structure, ACC block walls construction including built in furniture items complete all as specified and shown on drawings.Note:(i) Boring of pile and cast-in-situ of pile including its concrete and reinforcement shall be measured and paid separately under relevant Schedule.(ii) Cost of pile cap including RCC, reinforcement and form work & its earthwork are included in the quoted amount of this item. |
| 4 | Lumpsum price workedout by the tenderer for CAS IN SITU PILE as listed in Schedule ‘A’ Part-I(B) |
| 5 | Lumpsum price worked out by the bidder/ tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule 'A' Part-II. |
| 6 | Lumpsum price worked out by the bidder/ tenderer for ROAD, PATH, CULVERT AND HARDSTANDING as listed in Schedule 'A' Part-III |
| 7 | Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule 'A' Part-IV. |
| 8 | Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule 'A' Part-V. |
| 9 | Lumpsum price worked out by the bidder/ tenderer for BOUNDRY WALL, FENCING AND GATE as listed in Schedule 'A' Part-VI. |
| 10 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-VII |
| 11 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule 'A' Part-VIII. |
| 12 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule 'A' Part-IX. |
| 13 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule 'A' Part-X. |
| 14 | Sch 'A' Sec-XI (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col. 5 siginifies this fact only. |
| 15 | Boring for bored cast-in-situ piles 500 mm dia. in any type of soil using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed. |
| 16 | Boring for bored cast-in-situ piles 600 mm dia. in any type of soil using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed. |
| 17 | M&L for Reinforced cement concrete (design mix) M-30 grade design mix as in Cast-in-situ piles etc., complete all as specified and as directed. Note: Pile shall be casted as mentioned in drawings. However, for payment purpose the length of pile shall be measured up to cut off level only. The unit rate quoted shall be deemed to included this aspect. |
| 18 | Carrying out initial pile load tests for 500 mm dia pile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed. |
| 19 | Conducting low strain integrity test on 500 mm diameter RCC cast-in-citu piles, data analysis and submission of report. (min 10 piles per visit) complete all as specified and directed. |
| 20 | Carrying out routine pile load tests for 500 mm dia pile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed. |
| 21 | Carrying out initial pile load tests for 600 mm dia pile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed. |
| 22 | Conducting low strain integrity test on 600 mm diameter RCC cast-in-citu piles, data analysis and submission of report. (min 10 piles per visit) complete all as specified and directed. |
| 23 | Carrying out routine pile load tests for 600 mm dia pile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed. |
| 24 | Design, Supply, Installation, Testing and Commissioning of Factory fabricated, vertical type Multi Grade Sand Filter- Vessel Dia - 2800 mm (min), Vessel HOS - 2175 mm (min), Filtration Flow Rate- 80 m³/Hr (max.), Dishend Thickness -10 mm, Shell Thickness - 8 mm , Made of MS internal epoxy painted with collector arms and distributers made ms heavy pipe, frontal piping with 150 mm valve for filtration ,backwash & rinse process . working pressure 2.5 Kg/cm2 , desgn pressure - 3.5 kg/cm2 , Test Pressure 5.0 Kg/cm2 confirm to IS-2062. Filter Media Details along with minimum shall be as per details given below [i] Quart Z Pebbles of 1\\" to 3/4\\" not less than 100 mm thick layer[ii] Quart Z Pebbles of 3/4\\" to 1/2\\" not less than 100 mm thick layer[iii] Quart Z Pebbles of 1/2\\" to 1/4\\" not less than 100 mm thick layer[iv] Quart Z Pebbles of 1/4\\" to 1/10\\" not less than 100 mm thick layer[v] Quart silica sand of assorted sizes not less than 900 mm thick layer [vi] Back wash arragement shall be made to facilitate the back washing system |
| 25 | Serial item No. 12.010 continued...[vii] Pressure transmitter -02 Nos alongwith suitableinstrumentation to provide backwash alarm / display[viii] Air vent system with 25 mm pipe with gun metal valve[ix] Pressure relief valve ,nut and bolt and gasket for filter [x] Suitable size of main hole and hand hole.Filter Flow Rate : 80 M³/Hr.Filtration Velocity : 15 M³/Hr/M² (max.)Diameter : 2800 mmDesign details, scope of work, detailed technical specification shall be as specified in particular specification. |
| 26 | Supply, Installation, Testing and Commissioning of identical centrifugal filtration/backwash pumps,Horizontal end‑suction, 80 m³/h @ 24 m head, flooded suction IE3 motors, VFD‑ready, CI body, with pre filter in SS 316, with matching connection size including vibration eliminating rubber bellows , Bronze Impeller in, Motor shaft in Stainless steel AISI 316, Mechanical seal,(SiC/SiC/Viton) suitable for chlorinated pool water; IE3 TEFC motor; VFD‑rated; accessories: suction/discharge pressure gauges, vibration pads, flexible connectors, isolation valves, NRVs; installed on common suction (DN300), service header (DN300) and backwash header (DN200) with motorized changeover per pump. Motor -1450 RPM, Asynchronous,Four Poles, Continuous Opeartion F class insulation, protection IP-55, Operating voltage - 380V/ 3 phase, 50HZFlow Rate: 80 m3/Hr Head: 22-24 meterOperating modes: PEAK 240 m³/h (3 pumps, 3 filters), NON‑PEAK 80 m³/h (1 pump, 1 filter), BACKWASH 111-123 m³/h (2 pumps on VFD) + air scour (one filter at a time), set points via VFD.Valving: Add motorized service inlet/outlet valves on each MGPSF; automatic filter rotation in non‑peak.Controls: Flow‑setpoint (VFD), filter DP alarms, interlocked backwash logic, time‑of‑day scheduler.Note :(i) Pump shall be mounted on a concrete Foundation Projecting at least 15 cm above finished floor level inside pump pit(ii) Detailed design, operation and control shall be as specified in particular specification. |
| 27 | Design, supply, installation, testing and commissioning of Indoor type integrated VFD starter-cum-PLC motor control panel for pool filtration and backwash by operating 04 Nos filtration pumps (each ~ 80 m³/h, 3D+1S) and 01 No Air blower (339-400 m³/h @ 0.5 bar(g), 15 KW), including all internal protections, wiring, programming and HMI as per Annexure (design/logic/mode details). Backwash valves shall be manual; panel provides interlocks, timers and prompts.Technical Specs (panel only):(a) Power: 415 V, 3-phase, 50 Hz; Main MCCB 4P ≥ 160 A; Al/Cu busbars ≥ 240 A, earth bar.(b) Drives: 4 x VFD with MCCB/MCB 3P 32 Amp-04 Nos ≥11 kW (one per pump) with input choke & bypass contactor; 1 x Star/Delta starter with MCCB/MCB 3P 40 Amp-01 No ≥ 15 kW for blower.(c) Control: PLC (min. IO as per Annexure-A), HMI 10\\" touch screen, 24 VDC SMPS, Class-II SPD, selector switches HOA per motor, estop chain, door interlock.(d) Metering/Indication: V/A/Hz/kW on incomer, run/healthy/trip lamps, alarm buzzer.(e) Enclosure: Floor-standing IP54 CRCA, powder-coated, cooling fans with filters, labeled terminals, 20% spare space. |
| 28 | Serial item No. 12.012 continued...(f) Functions (as per Annexure): (i) Peak filtration: 3 pumps on VFD to hold Q≈240 m³/h, 1 standby with auto rotation. (ii) Non-peak: 1 pump on VFD to hold Q≈80 m³/h (one filter in service). (iii) Backwash 2 Pumps in parallel in VFD to hold Q ≈ 125 m³/h (one filter at a time) (iv) Backwash assist: step timers for air-only → air + water → water-only, interlocks to prevent unsafe starts; blower on VFD. (v) Trips/alarms for low suction, high discharge, VFD fault, motor thermistor; event log.(g) Control supplies (a) Control transformer: 415/230 V, 2 kVA (b) SMPS: 24 VDC, 10 A (PLC + HMI + instruments + relays) PLC + HMI PLC with: (i) Ethernet + Modbus (TCP/RTU) capability (ii) Minimum spare I/O: ≥20% (iii) HMI: 10 inch (recommended for prompts + alarms), IP65 front |
| 29 | Serial item No. 12.012 continued...(h) Ozonator integration (control only) (Ozone + chlorinator controls)1 × MCB feeder for ozonator control supply Run/Stop permissive (dry contact) from PLC to ozonatorInterlocks:Ozone enabled only when circulation flow proven (flow switch / flowmeter low alarm)Ozone disabled in drain mode/backwash assist mode (as per your safety philosophy)Status inputs:Ozonator healthy/fault (dry contact)ORP permissive (optional)Chlorinator integration (control only)Depending on technology:If dosing pumps (liquid chlorine): PLC enables dosing pumps based on ORP/free-Cl, flow permissive, and disables during drain/backwash.If salt chlorinator / electrolyser: PLC provides run permissive + reads fault/flow switch.Panel provisions:2 × MCB feeders (SP/DP/TP as required) for chlorinator + dosing accessories (final ratings below)Terminals for:ORP / free chlorine analyzer 4–20 mA (if used)pH analyzer 4–20 mA (if used)Dosing pump run/fault DI |
| 30 | Serial item No. 12.012 continued...I/O Details:Minimum field signals (I/O Schedule)Digital Inputs (DI)Pump-1/2/3/4: VFD healthy, run, trip/fault (or via comms)Blower run, blower faultBackwash mode selector permissive (key switch)Emergency stopLow level / high level from balancing tank (if provided)Filter-1 DP high, Filter-2 DP high, Filter-3 DP high, Filter-4 DP high (as applicable to your filter count)Door interlock / panel healthy (optional)DI: Ozonator healthy/fault; chlorinator/dosing healthy/faultAnalog Inputs (AI)Flowmeter (240 m³/h line) 4–20 mA (recommended)DP transmitters across filters 4–20 mA (recommended; or DI if only switches)(Optional) suction/discharge pressure transmitters 4–20 mAAI: ORP (4–20 mA), free-Cl (4–20 mA) if separate, pH (4–20 mA) |
| 31 | Serial item No. 12.012 continued...AI : flowmeter 4–20 mA; filter DP 4–20 mADigital Outputs (DO)Pump start enable to each VFD (if not purely comms)Blower start commandCommon alarm hooter/beacon“Backwash prompt” lamp (optional external stack light)DO: Ozonator enable; chlorinator enable; dosing enableAnalog Outputs (AO)Speed reference to each VFD (if not via comms)To ensure panel to match “manual valves”, add following: flowmeter + DP + level + E-stop + VFD status.Operating modes (HMI logic)Modes1. AUTO – FiltrationMaintain set circulation flow 240 m³/h using VFD speed control.3 duty pumps run; 1 standby in auto.Automatic duty rotation (weekly or run-hours based).2. MANUALIndividual pump/blower start/stop from HMI (with safety interlocks active). |
| 32 | Serial item No. 12.012 continued...(j) BACKWASH ASSIST (manual valves)PLC does not actuate valves; it enforces safe sequencing by prompts + permissive.Backwash assist sequence (manual-valve plant)HMI provides stepwise checklist and timers, e.g.:Select filter to backwash (Filter-1/2/3/4).Ensure filtration pumps running and stable.Prompt: “Set valves to BACKWASH position” (operator confirmation on HMI).Start air scour: blower ON, timer T1 (e.g., 3–5 min).Stop blower; prompt: “Set valves to BACKWASH WATER”.Maintain backwash water flow (by pump speed setpoint / throttling prompt) timer T2 (e.g., 5–7 min).Prompt: “Set valves to RINSE”.Rinse timer T3 (e.g., 1–2 min).Prompt: “Return valves to FILTRATION”.Log cycle; reset DP baseline.Interlocks during backwash assistBlower cannot start unless at least one filtration pump is running (or dedicated backwash pump running, if any).Backwash assist disables chemical dosing/heating/ozone commands (if integrated).Prevent simultaneous “air scour” and “rinse” where not permitted (logic lock). |
| 33 | Serial item No. 12.012 continued...(k) Pump control philosophy (3D+1S)Normal filtration: 3 pumps share load; PLC trims speed so combined flow meets setpoint.Standby auto-start: on any duty pump trip, PLC starts standby and restores flow.Anti-short cycling: minimum off-time and restart delay.Dry run protection: low balancing tank level trips pumps and raises alarm.Run hour equalization: weekly rotation or differential run-hours logic.(l) Alarms (minimum list)Low level balancing tank (trip + alarm) / High level balancing tank (alarm)Pump VFD fault / overload / overtemp / Blower faultFlow low (below setpoint for X seconds)Filter DP high (indicates backwash required)Emergency stop pressedPLC/HMI power supply fault |
| 34 | Serial item No. 12.012 continued...(m) Documentation & Tests: GA/SLD/Wiring diagrams/IO list, cause-&-effect, HMI screen list, FAT (panel) & SAT (site), O&M manuals, PLC logic description, functional checks & training for Auto duty rotation, standby cut-in, Backwash assist sequence prompts and timing, Alarm simulation and logging & Communication with VFDs and flowmeterInclusions: Panel internal components, control wiring, programming, factory testing, delivery, installation on plinth, termination up to panel glands.Exclusions (measured elsewhere): Field instruments/valves, external power & control cables beyond panel, civil works, earthing grid, LT incomer.Note: (i) Bidder’s rate shall be all-inclusive for the above scope.(ii) Detailed sequence/IO/mode logic shall be as per Annexure “Control Philosophy, P&ID & includes details given above”. |
| 35 | Supply, install, test and commisioning of air‑scour blower, MGPSF backwash: Type: oil free positive displacement tri lobe Roots blower, Q = 460 m³/h @ 0.5bar (g), motor 15 KW, IE3, TEFC, VFD‑ready; skid‑mounted with inlet filter, inlet & discharge silencers, NRV, PRV 0.6bar(g), pressure gauge, flexible connectors, baseframe and belt guard; paint system epoxy and all connected supports. Scope for common 125NB header, branch set with motorized butterfly valve and NRV, instruments shall be measured and paid separately under relevant BOQ items. (Duty: one filter at a time; 1W+1S arrangement). Air‑rate basis: 460 m³/h·m² for 5–7minAir Note :(i) Pump shall be mounted on a concrete Foundation Projecting at least 15 cm above finished floor level(ii) Detailed design, operation and control shall be as specified in PS. |
| 36 | Design, supply, installation, testing and commissioning of the following: (a) Hybrid Disinfection System (Ozonation + Automatic Variable Chlorination + pH dosing) comprising of complete ozone package located upstream of MGPSF including PSA oxygen system, 110 g/h oxygen‑fed ozone generator (turndown ≥20%), sidestream pump with VFD, venturi injector, 9.0 m³ baffled contactor (T10 ≥ 2.0 min at peak), degas separator, catalytic off‑gas destructor, static mixer on return to filter inlet manifold. Automatic variable calcium hypochlorite dosing system (1D+1S, 2000 L tank, agitator, VFD control), and pH dosing system; complete with flow / dissolved‑ozone analyzers (post‑contactor and on filter inlet manifold with trip at 0.05–0.10 mg/L), ORP (pre‑pool), chlorine + pH analyzer (pool return), PLC/HMI with interlocks, ambient O₃ detector, valves/NRVs/back‑pressure valve, ozone‑rated piping in PVDF/PTFE/Titanium with FRP‑lined vessels as applicable, supports, cabling from local JB to panel. Design details, scope of work, detailed technical specification shall be as per Annexure 'B'Commissioning, operator training, O&M manuals and 24-month warranty; all conforming to IS:8417, NSF/CE, ISO 9001 standardsPerformance Guarantees:• Dissolved ozone ≥0.30 mg/L at peak with ≥85% mass transfer• Free chlorine maintained at 0.4–0.8 mg/L (±0.1 mg/L)• pH maintained at 7.2–7.6 (±0.2)• Contact time T10 ≥ 2.0 minutes |
| 37 | Serial item No. 12.014 continued...• Full compliance with ozone safety regulationsMaterials and compatibility: All ozone‑wetted water/gas paths shall be PVDF/PTFE/Titanium/EPDM‑Viton (no stainless/uPVC). Stainless steel may be used in non‑ozonated sections only (downstream of MGPSF).(b) Ozone-rated plumbing system for the complete ozonation package of the swimming pool disinfection plant, including all interconnecting pipelines, fittings, valves and supports from the circulation pump discharge to the ozone sidestream loop, venturi injector, baffled contactor, degas assembly, catalytic off-gas destructor, and return to filter inlet manifold, as per technical specifications and design drawings.Scope:(i) All ozone-wetted piping in PVDF/PTFE/Titanium/FRP-lined MS (as per specs).(ii) Side-stream loop (≈25% of flow) with VFD-controlled pump, venturi ejector (PVDF/PTFE), static mixer (SS316L/PP/FRP).(iii) Interconnecting suction & delivery headers, valves, NRVs, isolation valves, back-pressure valves, pulsation dampers, injection quills.(iv) Ozone contactor (9.0 m³) connections, degas dome outlet to off-gas destructor, condensate drain.(v) Analyzer tapping points (dissolved ozone, ORP, chlorine, pH) as indicated.(vi) Supports, anchor blocks, flanges, gaskets (PTFE/Viton only), painting/coating for external protection.(vii) Testing (hydrotest, leak test), flushing, commissioning and handing over with O&M manuals.(viii) Materials (ozone-wetted): PVDF/PTFE/EPDM/Titanium. Avoid uPVC and SS304/316 in ozonated paths.(c) Plumbing system for the automatic variable chlorine dosing (Cal-Hypo 65%) and pH correction (acid) within the plant room, complete with all interconnections, fittings, valves, injection assemblies, and safety accessories, ready for operation.Plumbing scope includes :(i) Chemical storage & transfer: HDPE day tanks (2000L tank for agitator with level switches & venting), suction strainers, anti-vortex foot valves, calibration column (1 L), suction/discharge manifolds with isolation.(ii) Dosing lines: PVDF/PTFE (DN15–DN20) from pumps to injection points with containment/drip trays, NRVs, back-pressure valves, pressure relief, pulsation dampers, pressure gauges, flushing tees, sample cocks.(iii) Injection assemblies: Corrosion-resistant injection quills with NRV for chlorine and acid lines; spool piece and static mixer on clean-return header (where specified). |
| 38 | Serial item No. 12.014 continued...(iv) pH system optioning: Acid dosing: HDPE day tank (1×200–300 L), PVDF/PTFE dosing line with full valve set & injection quill (as above).(v) Analyzer tapping points (provisions only): threaded/flanged sockets for free-Cl₂, pH, and sample take-off loop on pool-return line.(vi) Supports & finishes: Pipe supports/clamps, tags, PTFE gaskets, external protective coating, hydrotest/flush and commissioning.Materials:(i) Dosing/wet chem lines: PVDF/PTFE/PP-H, EPDM/Viton seals; HDPE tanks.(ii) Headers/spools: MSRL/SS (non-chlorinated sections)Note for 4(a) & 4(b) : (i) Detailed design, scope of work and technical specification shall be as specified in PS.(ii) Quoted rates shall deemed to be inclusive of all fittings, small materials, supports, testing & commissioning for the dosing plumbing within plant room. |
| 39 | Supply, Installation, Testing and Commissioning of Floor inlet/diffuser, 32mm (flush type), rated 5-7m3/hr, UV stabilized ABS or bronze with SS316 trim, 32mm spigot/thread, O-ring seal, includes fittings elbow, socket, solvent all confirming EN-13451 (Pool circulation fittings, and connect via DN63/75 branches with branch isolation valve complete all as specified and directed. |
| 40 | Supply, Installation, Testing and Commissioning of min 350 mm width & min 22 mm thick Overflow Grating made of UV Stabilized PP in white colour with 01 gutter complete all as specified and directed. |
| 41 | Supply, Installation, Testing and Commissioning of Stainless Steel 304, 3 step standard ladders, width: 500mm, handrails dia 42 mm stainless steel, non-slip steps provided with anchoring Socket complete all as specified and directed. |
| 42 | Supply, Installation, Testing and Commissioning of Stainless Steel 304, 4 step standard ladders, width: 500mm, handrails dia 42 mm stainless steel, non-slip steps provided with anchoring Socket complete all as specified and directed. |
| 43 | Supply, Installation, Testing and Commissioning of Hand Rail, 1.2 meter long in Stainless Steel 304 complete all as specified and directed. |
| 44 | Supply, Installation, Testing and Commissioning Anodised Extruded Stainless Steel Vacuum Head - 900 mm SS fixed with clip type connection 1-1/2\\" complete all as specified and directed. |
| 45 | Supply, Installation, Testing and Commissioning Reinforced telescopic Handle 3.6-7.2 mtr long complete all as specified and directed |
| 46 | Supply, Installation, Testing and Commissioning Floating suction hose, made of polyethyene blue color 40 mm (1-1/2\\") 30 mtrs long complete all as specified and directed |
| 47 | Supply, Installation, Testing and Commissioning Water surface skimmer clip type complete all as specified and directed |
| 48 | Supply, Installation, Testing and Commissioning Curved brush clip type complete all as specified and directed |
| 49 | Supply, Installation, Testing and Commissioning Test kit for pH and chlorine complete all as specified and directed |
| 50 | Supply, Installation, Testing and Commissioning Algae Brush SS Bristles complete all as specified and directed |
| 51 | Supply, Installation, Testing and Commissioning Straight Brush clip type complete all as specified and directed |
| 52 | Supply of Trolley mounted suction sweeper kit, Trolly made of MS painted with wheels for smooth movement arrount the deck Including self priming, non-clog Trolley mounted suction SP Series pump capacity 2 HP including Nylon rope & starter with sutaible size and length of submersible cable complete in all respect 10 Nos. of float complete to support the hose, clips for connection complete all as specified and directed. |
| 53 | Supply of Life Bouy |
| 54 | Supply of Life Bouy hook |
| 55 | Supply of TCCA 90 pool disinfection chemical |
| 56 | Supply, laying, testing and commissioning of Sch 40 uPVC pipes 50 mm bore (pool grade) cut to required lengths including all necessary fittings (all confirming to EN1329/13592) and solvent welded, installed at 1-2% slope with long radius bends, access/cleanout tees, sleeves through walls, supports/anchors and leak testing, including all sundries, connect each drain outlet to header/line, provide thrust blocs at penetration and seal around sleeves complete all as specified and as directed.Note : Quoted rate is exclusive of Sleeves through walls/floors |
| 57 | Supply, laying, testing and commissioning of Sch 40 uPVC pipes 100 mm bore (pool grade) cut to required lengths including all necessary fittings (all confirming to EN1329/13592) and solvent welded, installed at 1-2% slope with long radius bends, access/cleanout tees, sleeves through walls, supports/anchors and leak testing, including all sundries, connect each drain outlet to header/line, provide thrust blocs at penetration and seal around sleeves complete all as specified and as directed.Note : Quoted rate is exclusive of Sleeves through walls/floors |
| 58 | Supply, laying, testing and commissioning of Sch 40 uPVC pipes 125 mm bore (pool grade) cut to required lengths including all necessary fittings (all confirming to EN1329/13592) and solvent welded, installed at 1-2% slope with long radius bends, access/cleanout tees, sleeves through walls, supports/anchors and leak testing, including all sundries, connect each drain outlet to header/line, provide thrust blocs at penetration and seal around sleeves complete all as specified and as directed.Note : Quoted rate is exclusive of Sleeves through walls/floors |
| 59 | Supply, laying, testing and commissioning of Sch 40 uPVC pipes 150 mm bore (pool grade) cut to required lengths including all necessary fittings (all confirming to EN1329/13592) and solvent welded, installed at 1-2% slope with long radius bends, access/cleanout tees, sleeves through walls, supports/anchors and leak testing, including all sundries, connect each drain outlet to header/line, provide thrust blocs at penetration and seal around sleeves complete all as specified and as directed.Note : Quoted rate is exclusive of Sleeves through walls/floors |
| 60 | Supply, laying, testing and commissioning of Sch 40 uPVC pipes 200 mm bore (pool grade) cut to required lengths including all necessary fittings (all confirming to EN1329/13592) and solvent welded, installed at 1-2% slope with long radius bends, access/cleanout tees, sleeves through walls, supports/anchors and leak testing, including all sundries, connect each drain outlet to header/line, provide thrust blocs at penetration and seal around sleeves complete all as specified and as directed.Note : Quoted rate is exclusive of Sleeves through walls/floors |
| 61 | Supply, laying, testing and commissioning of Sch 40 uPVC pipes 250 mm bore (pool grade) cut to required lengths including all necessary fittings (all confirming to EN1329/13592) and solvent welded, installed at 1-2% slope with long radius bends, access/cleanout tees, sleeves through walls, supports/anchors and leak testing, including all sundries, connect each drain outlet to header/line, provide thrust blocs at penetration and seal around sleeves complete all as specified and as directed.Note : Quoted rate is exclusive of Sleeves through walls/floors |
| 62 | Supply, laying, testing and commissioning of Sch 40 uPVC pipes 300 mm bore (pool grade) cut to required lengths including all necessary fittings (all confirming to EN1329/13592) and solvent welded, installed at 1-2% slope with long radius bends, access/cleanout tees, sleeves through walls, supports/anchors and leak testing, including all sundries, connect each drain outlet to header/line, provide thrust blocs at penetration and seal around sleeves complete all as specified and as directed.Note : Quoted rate is exclusive of Sleeves through walls/floors |
| 63 | Supply, Installation, Testing and Commissioning of 125 mm dia, heavy duty PVC puddle flanges Schedule 40 fixed with flanges, length 600 mm length on the wall of plantroom, balancing tank and the Swimming pool walls & Slab as required complete all as specified and directed. |
| 64 | Supply, Installation, Testing and Commissioning of 200 mm dia, heavy duty PVC puddle flanges Schedule 40 fixed with flanges, length 600 mm length on the wall of plantroom, balancing tank and the Swimming pool walls & Slab as required complete all as specified and directed. |
| 65 | Supply, Installation, Testing and Commissioning of 250 mm dia, heavy duty PVC puddle flanges Schedule 40 fixed with flanges, length 600 mm length on the wall of plantroom, balancing tank and the Swimming pool walls & Slab as required complete all as specified and directed. |
| 66 | Supply, Installation, Testing and Commissioning of 300 mm dia, heavy duty PVC puddle flanges Schedule 40 fixed with flanges, length 600 mm length on the wall of plantroom, balancing tank and the Swimming pool walls & Slab as required complete all as specified and directed. |
| 67 | Design, Supply, Installation, Testing & Commissioning of Swimming Pool Main plumbing system complete with suction header, delivery header, backwash header, Air line header, filter line header, Automatic variable Chlorine Dozing, Ozonation, & pH dosing system, complete system for the swimming pool circulation plant (capacity 240 m³/h, 4-hour turnover), including but not limited to:(a) Suction header DN300 from balancing tank with DN150 pump branches (3W+1S pumps), duplex basket strainers, isolation valves.(b) Pump discharge DN150 manifolds with NRV, isolation valves, gauges.(c) Common discharge header DN300 with flowmeter and pressure tappings. (d) Backwash header DN200 with flowmeter and pressure tappings.(e) Airline common header DN125 with reducer/adaptor at filter nozzle, branch set with motorized butterfly valve and NRV & instruments(f) Ozone side-stream tie-ins DN100 with valves, NRV, strainers.(g) Filter inlet/outlet DN150 headers (2 MGPSF filters) with isolation & NRVs.(h) Filtered water header DN300 complete with tie-ins.(j) Chemical dosing injection quills (pH & chlorine) with DN300 static mixers. |
| 68 | Serial item No. 12.043 continued...(k) Valves, gauges, air release, drains, flexible connectors at appropriate points.(l) Supports, anchors, identification, erection, flushing, hydrotest & commissioning.Note : i) Detailed tech specification & design condition shall be as specified in PS.(ii) Quoted rate shall deemed to be inclusive of all plumbing work incl all accessories, manual/motorised valves, non return valves & instrumentation & sensors from balancing tank outlet suction point (02 Nos x 300 mm dia of suitable length) to suction header DN300 & further to filtration plant to main return / filter line towards swimming pool till outside plant room plinth |
| 69 | Supply, laying, testing and commissioning PVC insulated sheathed, 1.5 Sqmm, single core FRLS multistranded flexible copper conductor cable complete all as specified and directed. |
| 70 | Supply, laying, testing and commissioning PVC insulated sheathed, 2.5 Sqmm, single core FRLS multistranded flexible copper conductor cable complete all as specified and directed. |
| 71 | Supply, laying, testing and commissioning PVC insulated sheathed, 6 Sqmm, 3 core FRLS multistranded flexible copper conductor cable complete all as specified and directed. |
| 72 | Supply, laying, testing and commissioning PVC insulated sheathed, 6 Sqmm, 4 core FRLS multistranded flexible copper conductor cable complete all as specified and directed. |
| 73 | Supply, laying, testing and commissioning PVC insulated sheathed, 10 Sqmm, 4 core FRLS multistranded flexible copper conductor cable complete all as specified and directed. |
| 74 | Supply, laying, testing and commissioning of heavy duty flexible rubber cable 6 Sqmm , 3 core, 450/750V rating, EPR-insulated, chloroprene/neoprene-sheathed, fine stranded Copper conductor cable for swimming pool application alongwith PVC-U conduit and its fixing accessories complete all as specified and directed. |
| 75 | Supply, laying, testing and commissioning of heavy duty flexible rubber cable 6 Sqmm , 2 core, 450/750V rating, EPR-insulated, chloroprene/neoprene-sheathed, fine stranded Copper conductor cable for swimming pool application alongwith PVC-U conduit and its fixing accessories complete all as specified and directed. |
| 76 | Supply, laying, testing and commissioning of heavy duty flexible rubber cable 2.5 Sqmm , 2 core, 450/750V rating, EPR-insulated, chloroprene/neoprene-sheathed, fine stranded Copper conductor cable for swimming pool application alongwith PVC-U conduit and its fixing accessories complete all as specified and directed. |
| 77 | Supply, laying, testing and commissioning 25 mm bore Heavy grade PVC electrical conduit with duct,saddles, lugs complete as specified and directed. |
| 78 | Supply, installation, testing and commissioning of GI perforated Cable Tray 150 mm wide complete all as specified and directed. |
| 79 | Supply, installation, testing and commissioning of GI perforated Cable Tray 200 mm wide complete all as specified and directed. |
| 80 | Supply, installation, testing and commissioning of GI perforated Cable Tray 300 mm wide complete all as specified and directed. |
| 81 | Supply, installation, testing and commissioning of GI Earthing Wire-8 SWG complete all as specified and directed. |
| 82 | Supply, installation, testing and commissioning of MS Structure work (MS Angle, Fastners, Tie Rods) for pipe support and pump footing complete all as specified and directed. |
| 83 | Supply, installation, testing and commissioning of Under water swimming pool LED luminaire with the folloing specifications:-(a) 30-36W, 24V AC, ≥3000lm, 4000K, 110-120° beam, CRI ≥ 80(b) 24V, AC SELV, Class-III double-insulated(c) IP68, IK10, SS316L front + tempered glass(d) Niche type with rear conduit entry, silicone gaskets, captive screws(e) Each with 5m factory-moulded cable tail, HO7RN-F or equivalent(f) Wall mounted type with built-in driver, including push in connector in 4 pole, including all fixing arrangement in swimming pool wall to accommodate pool light. |
| 84 | Supply, install, testing & commissioning of Swimming Pool lighting panel, IP54 protection, floor-standing of suitable size with sufficient spacing for fixing of breakers and cable termination, suitable for 415V, 3 phase, 4-wire, 50 Hz, AC supply system, totally enclosed, dust, weather & vermin proof, 2.0mm thick for outer shell and 2 mm thick for inner shell having TPN copper busbars epoxy sleeved, colour coded of rating 1.5 times minimum that of controlling MCBs supported on SMC insulators with short-circuit withstand capacity ≥16 kA/1s, bottom base channel of MS section not less than 50mm x 50mm x 6mm thick, entire panel shall have a common copper earth bar of suitable size at the rear with 2Nos earth earth stud, solid connection from main bus bars to switchgears with required size of copper bus bars and control wiring with minimum 1.5sqmm FRLSZH, cable alleys, cable gland plates in two half including digital Multi-function meter to measure voltage, current, PF, kWH, kVAH,etc (Make: Secure/L&T/Schneider), Type-2 SPD and general construction confirming to IS:8623/93 and suitably mounted on wall with all fixing accessories complete with following detailed specification and controls:- |
| 85 | Serial item No. 12.059 continued...Instrumentation details:-(a) Control MCB 6A, SP, 10kA - 01 No(b) Timer 24H mounted on DIN rail, 230V - 01 No(c) HOA Selector switch 3 position - 01 No(d) Pushbuttons and LED indicators - Step-1, Step-2, Power & RCD trip - 01 set(e) Neutral & Earth busbar : Copper rating 125A (with connecting studs)(f) FRLSH 4.0 sqmm x 2C wire from RCBO to Transformer primary(g) Engraved tags on wiring for identification, cable lugs, saddles and other necessary accessories as required for complete jobIncoming :-(a) MCCB 63A, 4P, 25kA, Type-C, fixed thermal & fixed magnetic release - 01No(b) Surge suppressor Type-2, 3P+N, 275V, Imax 40kA - 01 NoOutgoing :-(a) RCBO 10A, 1P+N, 230V, 30mA with short circuit capacity & Over-load protection- 08 Nos (6W + 2S)(b) Contactor AC-1 16A, 230V coil - 08 No (6W + 2S)Note : The cost of material, labour and tools required for civil opening, core cutting, making good, non-shrink grout around niches, water tight conduiting in entire swimming pool area and making good the disturbed surfaces is deemed to be included in the above quoted rate. |
| 86 | Supply, Installation, testing and commissioning of Transformer Enclosure (3-circuit, 24 V AC SELV) Near-pool, IP65/66, outdoor-duty, powder-coated CRCA/Alu or FRP cabinet with rain canopy, SS316 hardware, pad-lockable door, neoprene gasket, anti-condensation space heater with thermostat, drip shield, insect filter/vents, bottom/top gland plates, internal DIN rails, copper earth bar including with MCB 16A, DP, 10kA, Type-D - 05 Nos (Transformer secondary) (4W + 1S). Size adequate for 6 transformers and wiring, min clearances maintained. Include nameplates, warning labels, and engraved circuit tags (C1–C4,C5-C8)Detailed technical specification shall be as specified in PS. |
| 87 | Supply, Installation, testing and commissioning of Isolation transformers, 230/24 V AC, resin-encapsulated, Rating: 0.63–1.0 kVA (select to suit 4 luminaires/circuit at 30–36 W), Class F/H, efficiency ≥94%, thermal cut-out, separate primary/secondary chambers, terminals shrouded. Compliance: IEC/IS for isolating transformers.Detailed technical specification shall be as specified in PS. |
| 88 | Supply, Installation, testing and commissioning of resin/gel-potted deck junction box with the following specifications:-(a) Suitable for 24V AC SELV circuits, size ≥ 160x16 x90mm for upto 3-4 luminaires & ≥200x200x100mm for upto 5-6 luminaires, SS316 hardware, fixed on SS316 bracket or wall with SS316 captive screws, internal M6 earth stud(b) 6xM20 entries with glands and blanks, internal terminals (2x6 sqmm loop + up to 4x2.5 sqmm lamp pairs)(c) Location : Mounted ≥ 1.2m from water edge and ≥ 0.3m above finished deck, cable entry from below/side(d) Enclosure : material UV stabilized glass-reinforced PC/PA or SS316, lid with continuous silicone gasket(e) Protection : IP68 (immersion ≥5m for 72h) and IK08minimum(f) Cable entries & glands : 4-8 threaded entries, M20(min) with IP68 glands & blanks, Glands PA66 or nickel-plated brass with neoprene seals, clamping ø6-12mm, one dedicated gland per luminaire tail, seperate glands for feeder In and feeder OUT (looping). |
| 89 | Supply, Installation, testing and commissioning of Starting platform/starting blocks adjustable platform in polyester and fiberglass with non-slip finish of size 500 mm x 500 mm x 400 mm ht with frame in SS 304 polished finish complete all as specified and directed. |
| 90 | Supply, Installation, testing and commissioning of Anchor Fastener , Anchor Bracket SS 304 complete all as specified and directed. |
| 91 | Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32x6 mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternatee layer complete all as specified and directed.Note : -The cost of GI strip and protection pipe in above mentioned item upto 7.50 m length is included in the quoted rate of this item and the length required beyond the 7.5 m shall be measured and paid separately. |
| 92 | M&L for earth continuity conductor, aluminium strip of size 25x3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other situation for loop earthing complete all as specified and as directed |
| 93 | Supply, installation, testing and commissioning of factory made powder coated compartmentalized cubicle type LT Panel indoor type of appropriate size and fabricated from 2.0 mm thick CRCA sheet steel with necessary MS angle iron frame work (50X50X6mm), weather proof, vermin proof, suitable rating copper bus bar chamber for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, inter connections, earthing terminals, labeling , cable alley suitable for termination of cables including supply and fixing of following switchgear and accessories in the panel complete as required size. The panel should be IP-54 protection including necessary foundation for mounting all as specified and directed by Enginer in charge. (Main LT panel indoor)Instrumentation :-(i) Digital Voltmeter (0-500 Volts) with selector switch -01 No(ii) Digital Ampere meter (0-250 A) with selector switch - 01 No(iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set(iv) MCB 6 Amp SP - 01 No |
| 94 | Serial item No. 12.067 continued...Incoming (i) MCCB 4 pole 250 Amp 25 KA 415V with microprocessor release setting conform to IS/IEC 60947-2 & adjustable overload From .1-1.0 X In Adjustable Short Circuit from 1.5-8 X Ir with selectable time dealy,fault protection from 10% -50 % of li,Adjustable neutral overload protection available 50% to 150 % of Ir - 01 No Outgoing :- (i) MCCB 4 pole 160 Amp 16 kA 415V, fixed thermal & fixed magnetic release - 02 Nos (01W + 01SB) (for Motor Control Panel)(ii) MCCB 4 pole 63 Amp 16 kA 415V, fixed thermal & fixed magnetic release - 03 Nos (02W + 01SB) (for Pool Light Control panel & Drain Pump Control Panel)(iii) MCB TP 32A, 16kA - 04 Nos (03W + 01SB) (for Ozonator, TPN DB for Building Light & power Point) |
| 95 | Supply, laying and testing under ground cable PVC insulated ,screened, PVC bedded, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core including fixing on wall/roof/cable tray as per site requirement including its fixing accessories complete all as specified and as directed |
| 96 | Supply, install, testing and commissioning of Smart energy meter (IS-16444), AC whole current, three phase, 4 wire, CT operated Smart Energy meter of Class 0.5 S, 415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site condition and as per design consideration of AMI implementing agaency to meet the performance. The smart meter can based on RF Mesh communication technology or Cellular communication technology. The meter shall be provided with transparent polycarbonate ABS thermoplastic box with sealing arrangemenrs of suitable size as per the requirement of OEM of electric meter. The cost of meter would include the supply of current transformer, rated burden 15VA, accuracy class 0.5S, frequency 50Hz and voltage class 660V, effectively earthed and CT ratio suitable as (60/5 to 1000/5) complete all as specified and as directed |
| 97 | S&F water proof submersible flat copper conductor cable 10 Sqmm 3 core, 3 phase, 440 Volts complete all as specified and directed. |
| 98 | Supply, installation, testing and commissioning of submersible drainage pump suitable for emptying swimming pool water during cleaning/maintenance, of capacity 60 m³/hr at 15 m head, driven by 7.5 kW (10 HP), 415 V, 3-phase, 50 Hz motor, suitable for chlorinated pool water, complete with non-clog/vortex impeller, IP-68 motor protection, Class-F insulation, thermal protection, factory-fitted submersible cable tail, lifting chain, all necessary mechanical seals, fasteners and accessories, including guide rail system with duck-foot bend, base elbow, discharge pedestal, and fixing arrangements, complete in all respects including providing and fixing guide rail system including duck-foot base elbow, guide rails (HDG/SS), lifting chain, anchor bolts, fasteners and all associated fittings for submersible drainage pump, suitable for installation in drain pit, including all accessories complete all as specified and directed |
| 99 | Supply, fixing, testing and commissioning of level control system comprising float switches/level sensors for LLL, LL, HL and HHL levels, including mounting brackets, cables, clamps, terminations at LT panel, calibration and functional testing, including all accessories complete all as specified and directed. |
| 100 | Supply, installation, testing and commissioning of Drain Pump Control Panel suitable for operation of two submersible drainage pumps (1 Duty + 1 Standby) of 7.5 kW each (Auto Duty-Standby), fabricated from CRCA sheet steel, powder-coated, IP-54 protection, comprising MCCB incomer 3P 63 Amp, Star-Delta/DOL starter with MCCB/MCB 3P 32 Amp-02 Nos ≥ 7.5 kW for pool drain pump for each pump, contactors, thermal overload relays, single-phasing/phase-reversal protection, under/over-voltage protection, auto duty–standby changeover logic, auto/manual selector switches, pump run/trip indications, R-Y-B indication lamps, digital voltmeter and ammeter, control MCBs, terminal blocks, wiring, earthing studs, audible alarm and emergency stop, complete with interlocking provision to disable ozone/chlorine/pH dosing and heating system during drain mode, including all accessories complete all as specified and directed. |
| 101 | Providing and fixing pump discharge piping from drain sumps to balancing tank, drain line TEE to submersible pump & then submersible drainage pumps to common DN200 waste line, including non-return valve, isolation butterfly valve, throttling valve, dismantling joints, supports, splash control at discharge point and all fittings, including all accessories complete all as specified and directed.Notes: For Item No 12.071 to 12.074:(i) Drainage pumps shall be used only for pool emptying/maintenance and shall not form part of normal circulation.(ii) Drain Pump Control Panel shall be interlocked to prevent operation of ozone, chlorine, pH dosing and heating systems (if available) during drain mode.(iii) All equipment shall be suitable for operation in wet/chlorinated environment.(iv) Rates quoted shall be inclusive of all labour, materials, testing, commissioning and incidental works required to make the system fully functional. |
| 102 | M&L for Cutting of existing pipe line and inserting Tee of size 200 x 150 x 200 mm along with fixing of necessery fittings and fixtures such as tail piece expansion /crumble joint including excavation and earth work complete all as specified and directed. |
| 103 | Supplying, laying, jointing and testing of DI pipe of size 150 mm dia (6\\") as per IS 8239/2000 class K-9 with inside cement mortar lining with spigot and socketed end including rubber gasket joint (tyton joint) laid in trenches complete all as specified and as directed. |
| 104 | Supply, laying and testing cable XLPE insulated un-armoured electric power cables 600-1100 volts grade copper conductor of 50 Sqmm 4.0 core as per IS 7098 (Part 1) 1988 complete all as specified and directed.(From LT Panel to Motor Control Panel) |
| 105 | Supply, laying and testing cable XLPE insulated un-armoured electric power cables 600-1100 volts grade copper conductor of 25 Sqmm 4.0 core as per IS 7098 (Part 1) 1988 complete all as specified and directed.(From LT Panel to Motor Control Panel) |
| 106 | Supply and lay Rubber mat of 1 meter x 2 meter x 10 mm complete all as specified and directed. |
| 107 | Boring of holes under road, pavement, hard standing by trenchless technology technique for 40-80 mm dia pipe complete all as specified and directed. |
| 108 | Supplying, installing (wall mounted or ceiling suspended), testing and commissioning power busbar trunking system of rated current 250 A, suitable for continuous duty, for use on 415 V, 3-phase, 4-wire, 50 Hz AC supply, conforming to IEC 61439-6, fully type-tested as a complete system.The busbar trunking shall be sandwich / compact type, air-insulated, with metallic enclosure, degree of protection IP-55 minimum, suitable for indoor workshop environment.The system shall comprise of aluminium busbars, with current density and temperature rise within IEC limits, and with neutral conductor rated minimum 100% of phase rating. The busbar trunking shall have short-circuit withstand capacity not less than 30 kA for 1 second (Icw), type-tested, with declared peak withstand (Ipk).The enclosure shall be corrosion-protected (powder coated or equivalent) and mechanically robust as per OEM design and type tests. The system shall include all standard straight lengths, end-feed units, elbows/bends where required, expansion units for long runs, plug-in tap-off boxes, joint covers, phase identification, integral earth continuity, supports, clamps, hangers, fasteners, and all accessories required for a complete installation. Earthing shall be integral to the system as per OEM design, with continuous earth continuity across all joints and suitable connection to the building earthing system.Installation, testing and commissioning shall include insulation resistance tests, earth continuity tests, functional checks of joints and tap-offs, and submission of type test certificates, routine test certificates, and as-built drawings, complete all as specified and directed |
| 109 | Sreial item No. 12.081 continued...Note: (i) The busbar trunking system is proposed as straight horizontal runs fed through LT cables from feeder panels. Accordingly, no vertical risers, bends, flanged ends, separate fixing clips, or external flexible jumpers are envisaged. All necessary supports, jointing provisions, earthing continuity, and expansion accommodation shall be integral to the OEM busbar trunking system and included within the main busbar trunking item.(ii) Busbar trunking shall be fed through LT cables from feeder/MDB via OEM end-feed units. No adaptor boxes, interconnecting busbars, or end-feed panels are envisaged. Each busbar trunking run shall remain electrically independent and shall not be interconnected with any other busbar run.(iii) Quoted rate shall be exclusive of item such as End feed unit, End Termination, Expansion unit & Plug in Tap off Boxes. The same shall be measured & paid separately under relevant item of schedule |
| 110 | S&F LED based Flood light, housing made up of pressure die cast aluminum Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 135 lumen/Watt and maximum system wattage of 70 Watts. The LEDs used shal lof CCT 5700°K / 6000°K CR≥80 & SDCM≤5, UGR≤22 . The Life shall be 50000Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07.The fixture driver should have an operating voltage range of 140-270 V, In-built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaier shall have 10KV SPD bolted inside the luminaire, flicker free (flicker should be less than 5%), suitable tiltable fitting including suspension kit or rigid bracket. The luminaire driver & SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \\"FAT\\" before dispatch as per IS 10322. The the successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Technical bid. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and directed.NOTE: Contractor has to provide warranty upto 5 Years. |
| 111 | S&F LED based Medium Bay light, housing made up of pressure die cast aluminum Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 140 lumen/Watt and maximum system wattage of 70 Watts. The LEDs used shal lof CCT 5700°K / 6000°K CR≥80 & SDCM≤5, UGR≤22 . The Life shall be 50000Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07.The fixture driver should have an operating voltage range of 140-270 V, In-built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaier shall have 10KV SPD bolted inside the luminaire, flicker free (flicker should be less than 5%), suitable tiltable fitting including suspension kit or rigid bracket. The luminaire driver & SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \\"FAT\\" before dispatch as per IS 10322. The the successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Technical bid. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and directed.NOTE: Contractor has to provide warranty upto 5 Years. |
| 112 | S&F LED based Medium Bay light, housing made up of pressure die cast aluminum Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 140 lumen/Watt and maximum system wattage of 35 Watts. The LEDs used shal lof CCT 5700°K / 6000°K CR≥80 & SDCM≤5, UGR≤22 . The Life shall be 50000Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07.The fixture driver should have an operating voltage range of 140-270 V, In-built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaier shall have 10KV SPD bolted inside the luminaire, flicker free (flicker should be less than 5%), suitable tiltable fitting including suspension kit or rigid bracket. The luminaire driver & SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \\"FAT\\" before dispatch as per IS 10322. The the successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Technical bid. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and directed.NOTE: Contractor has to provide warranty upto 5 Years. |
| 113 | S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW, complete of capacity 50 Ltrs, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pieces for for hot and cold water complete and including all fixing accessories complete all as specified and directed.NOTE: - Contractor has to provide 5 years warranty from the date of installation. |
| 114 | S&F Modular blanking plate modular type suitable for fixing in modular switch board, complete all as specified and as directed. |
| 115 | S&F Surge Protection Device (SPD) 4 module, 25 KA, 3Ph+N Right, T1+T2, limp 12,5 KA per pole, T2-60KA, complete and making connections by using necessary thimble/washersetc of copper/brass material complete all as specified and directed. (For Main DB) Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy