| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 mtr, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 mtr . |
| 2 | M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundations filling in mass concrete all as directed by Engineer in Charge. |
| 3 | Returning, filling in and including spreading, levelling, watering and well ramming in layers not exc 25 cm all as directed by Engineer in Charge. |
| 4 | Removing excavated material (soils) exc 250 mtr but not exc 500 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 5 | M&L for approved good earth filling in floors or pavings, laid in layers not exc. 15 cm thick, spread, levelled and rammed including watering all as directed by Engineer in Charge.Note : Earth obtained from excavation shall be used. |
| 6 | M&L for Hardcore of guage exc 63mm but not exc. 100 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as directed by Enginer in Charge. |
| 7 | M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in floor 100 mm thick complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for Treating the bottom and sides of excavation at the rate of 5 litres of ATT emulsion per square metre of surface area all as directed by Engineer in Charge. |
| 9 | M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of ATT emulsion per square metre of vertical surface all as directed by Engineer in Charge. |
| 10 | M&L for treating the top surface of filled earth at the rate of 5 litres of ATT emulsion per square metre of surface all as directed by Engineer in Charge. |
| 11 | M&L for treating the soil under plinth protection at the rate of 5 litres of ATT emulsion per square metre of surface area all as directed by Engineer in Charge. |
| 12 | M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of ATT emulsion per metre of the perimeter wall all as directed by Engineer in Charge. |
| 13 | M&L for brick work with old size bricks, straight or curve on plan exc 6mtr mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 14 | M&L for brick work with old size bricks, straight or curve on plan to any radius in half brick thick wall built in cement mortar 1:6 complete all as specified and directed. |
| 15 | M&L for RCC M25 grade (Design mix) (with 20 mm graded stone aggregate) as in foundation, footing & plinth beam etc complete all as specified and directed. |
| 16 | M&L for RCC M25 grade (Design mix) using 20mm graded stone aggregate as in roof beam & lintel band complete all as specified and directed. |
| 17 | M&L for RCC M25 grade (Design mix) using 20mm graded stone aggregate as in roof slab complete all as specified and directed. |
| 18 | M&L for RCC M25 grade (Design mix) (with 20 mm graded stone aggregate) as in column complete all as specified and directed. |
| 19 | M&L for RCC M25 grade (Design mix) using 20mm graded stone aggregate as in chajja/ shelf complete all as specified and directed. |
| 20 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface all as specified & directed by Engineer in Charge. |
| 21 | M&L for form work to sides of pillars,posts, struts, piers, columns and stanchions landing and similar work, complete all as specified and directed. |
| 22 | M&L for formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc all as specified & directed. |
| 23 | M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work, not exceeding 200 mm thick (Horizontal or sloping) of flat surfaces of concrete complete all as specified and directed. |
| 24 | M&L for formwork fair finished surfaces to chajjas,troughs and similar items including edges all as specified & directed by Engineer in Charge. |
| 25 | M&L for TMT steel bars 10mm dia and over cut to length bent to shape required, incl cranking bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as directed by Engineer in Charge. |
| 26 | All as per item no 25.00 here in above but 5mm dia & over upto and incl 10mm dia in stirrups, spacers and binders all as specified and directed. |
| 27 | M&L for coloured Non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. premium quality, Gr-1 set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15 mm thick screed bed or bedding layers in cement mortar (1:4) complete all as specified and directed. |
| 28 | M&L for coloured Virified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and as directed. |
| 29 | M&L for colour glazed ceramic coloured tiles 350mmx250mmx7mm/ 450x350x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement as in vertical surfaces such as skirting, dados and risers to steps etc to match with and including 10 mm thick screed bed or bedding layers in cement mortar (1:3) complete all as specified and directed. |
| 30 | M&L for Coloured rubber moulded Chequered cement concrete tiles 300 x 300 x 25mm thick, set jointed and pointed in grey cement mixed with pigments in floors, over 20mm screed bed in CM 1:6, complete all as specified and directed. |
| 31 | M&L for rendering 5mm thick on concrete ceiling surfaces in cement mortar 1:3 finished surfaces fair and even complete all as specified and directed. |
| 32 | M&L for Rendering 15mm thick on fair faces of brick or concrete surfaces in CM (1:6) finished even and smooth without using extra cement all as directed by Engineer in Charge. |
| 33 | M & L for rendering 15mm thick on fair faces of brick or concrete wall surfaces in cement mortar 1:4 finished surfaces fair & even using WPC (Water Proofing Compound) as per manufacturers instructions complete all as specified and directed.Note : WPC measured and paid separately. |
| 34 | Supply only Integral waterproofing compound complete all as specified and directed. |
| 35 | M&L for preparation of newly plastered wall surfaces and applying two coats of Oil Bound Distemper over a coat of chalk whiting (preparatory to distemper) applied over 1 to 2 mm thick BIRLA/ JK (or equivalent) water-proof wall care putty complete all as specified and directed by Engineer -in-Charge. |
| 36 | Material & Labour for Preparing new plastered or unplastered surfaces and applying Two coats of 100% Premium acrylic emulsion paint (camouflage pattern) , Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 37 | M&L for three coats of white wash to newly plastered surface of ceiling incl preparation of surfaces complete all as specified and directed. |
| 38 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker, Secondary Strikers, Cylinder, Door transmission gear made of mild steel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated). (Note: The unit rate quoted by contractor includes all other connected accessories. |
| 39 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Note: The unit rate quoted by contractor includes all other connected accessories.(A) Area not exceeding 2.00 sqm each. |
| 40 | S&F for Anodised aluminium grill (Min thickness 5.2mm and of 2.4Kg/Sqm weight) of approved design/ pattern, with approved standrad section and fixed to existing window frame with CP brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in Charge. |
| 41 | S & F for Aluminium Mortice lock, vertical type of size 75 mm, 4 lever, complete all as specified and as directed by Engineer-in-Charge. |
| 42 | Supply & fixing 5.5 thick sheet glass, ordinary quality in square exc 0.5m in each pane complete all as specified and directed. |
| 43 | S&F of 500 Litres Capacity, HDPE (Double layered) Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, Complete all as specified and directed. |
| 44 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs concrete floor finishing complete all as specified and as directed. |
| 45 | S&F of 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball (Minimum weight 455 gms), complete all as specified and directed. |
| 46 | M&L for 20 mm dia Gate valves with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed. |
| 47 | S&F of CPVC 16mm bore, SDR -11 Grade for hot and cold water with all fittings fixed complete to walls and ceilings or laid in floors all as directed by Engineer in Charge. |
| 48 | S & F of CPVC 20 mm bore, SDR -11 Grade for hot and cold water with all fittings fixed complete to walls and ceilings or laid in floors all as directed by Engineer in Charge. |
| 49 | M & L for vitreous china wash down water closet pan (pedastal pattern), including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device (excluding fixing bolts, flushing cistern and flush pipe) all as directed by Engineer in Charge. |
| 50 | S & F of squatting pan vitreous china orrisa pattern of Size 580mmx440mm \\"white\\" with integral foot rest (Excluding flushing cistern and flush pipe) including provision of cement concrete bedding, connection to trap and to flushing pipe, anti-syphonage pipe etc complete making good to floor complete all as specified and directed. |
| 51 | S & F PVC valveless, syphonic action type flushing cistern 10 ltr capacity low level white with inlet ball valve float and handle including brackets, Flush pipe of polyethylene of low or high density or PVC 32mm dia, for low level cistern, all as specified and directed. |
| 52 | S & F for PVC Health faucet with all accessories, complete all as specified and directed. |
| 53 | S&F over head shower brass CP 125mm dia round shape sigle flow with necessary extension pipe from wall complete all as specified and directed. |
| 54 | S & F bip taps 15mm chromium plated cast copper alloy with crutch or butterfly handle, screw down for iron pipe or for brass ferrule all as specified & directed by Engineer in Charge |
| 55 | M & L for vitreous china wash basin of size 630 x 450mm, white, flat back, including brackets , 15mm bore pillar taps chromium plated, 32mm bore dia Waste coupling of PTMT (half or full threaded) , cutting for and pinning in ends of brackets or erecting stand, complete all as specified and directed. |
| 56 | S & F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed. |
| 57 | S&F in repairs soap dish, viterous china white approximate size 160X160X90mm complete all as specified & directed |
| 58 | S&F for tubular towel rail, brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed. |
| 59 | S & F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC bldg board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as secified. |
| 60 | S&F 15mm dia stop valves, fancy type chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed. |
| 61 | S&F PVC connections 15mm size with PTMT nuts of length 450mm , complete all as specified and directed. |
| 62 | M & L for PVC floor trap, 75 mm dia, with grating including jointing with solvent cement, complete all as specified and directed. |
| 63 | S&F 32 mm bore (LDPE) pipes of pressure rating 6 kgf/sqcm, in waste pipe of WHB / Sink, fixed complete to walls,ceiling or in floors etc all as specified and directed. |
| 64 | S & F PVC 75mm (SWR ) pipe single socketed in any length with rubbering joints fixed to walls, complete all as specified and directed. |
| 65 | S & F PVC (SWR) bend 75mm bore any radius complete all as specified and directed. . |
| 66 | S & F 110mm bore PVC (SWR ) pipe single socketed in any length with rubbering joints fixed to walls including removal of old damaged PVC pipe, complete all as specified and directed. |
| 67 | S & F PVC (SWR) bend 110mm bore any radius all as specified and directed. |
| 68 | S&F 110mm bore PVC (SWR) junction single Tee equal or unequal complete all as specified and directed |
| 69 | S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 70 | M&L for cutting chases for concealed water tubing and making good to surface as required in cement mortar 1:3 etc. in Brick wall and concrete. Walls & cutting not exceeding 10 cm girth complete all as specified and directed. |
| 71 | M&L for applying water proofing treatment with the following complete all as specified & directed :-(a) First coat of hot blown bitumen with bitumen 85/25 grade @1.20 Kg/Sqm over bitumen primer @0.3 litre/Sqm.(b) Second layer of APP based polymeric membrane minimum weight 3.5 Kg/Sqm and minimum 3.0mm thick reinforced with polyster non woven fabric (wt not less than 160 gms/Sqm) laid on primed surface by torched application.(c) Third layer i.e. a coat of hot blown bitumen 85/25 @ 1.2 Kg/Sqm shall be applied over water proofing membrane. |
| 72 | M&L for rendering 10mm thick cement mortar 1:4 on concrete surfaces as in roof treatment using WPC @3% by weight even & smooth without using extra cement complete all as specified and directed. NOTE: WPC measured and paid separately. |
| 73 | S&F factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with mild steel square tube in opening as per specification and drawing complete all as specified and directed. |
| 74 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails, MS frames shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, Paneling of plain colour PVC sheet to be fitted in the MS frame welded/ scaled to the stiles and rails with suitable PVC Sheet beading and jointed together with solvent cement as per drawings and specifications complete all as specified and directed. |
| 75 | M&L for concrete bed to drain pipes of size 150 mm bore packingunder and haunching against the sides of pipes after theyare laid and fitted in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed. |
| 76 | M&L for PCC 1:2:4, Type B–0, using 12.5 mm graded stone aggregate as in coping including use and waste of formwork and finishing the exposed faces of concrete even and smooth without using extra cement complete all as specified and as directed. |
| 77 | PCC 1:2:4 type B2 (using 40mm graded stone aggregateas in surface channels/benching and drains complete allas specified and directed. |
| 78 | M&L for 75mm thick PCC (1:3:6) type C2 using 40mm graded stne aggegate as in plinth protection, surface finished even and smooth complete all as secified & directed by Engineer in Charge. |
| 79 | M&L for Precast RCC 1:2:4, Type B-1 using 20mm graded stone aggregate as in landings, cover slabs [for manholes etc],chullah hoods, Chajjas, water troughs, mangers, Shelvesand similar articles with plain faces including formwork, set in cement mortar 1:4 complete all as specified and as directed. |
| 80 | M&L for Reinforced concrete pipes, class NP2, laid and jointed complete with collars pipe 150mm bore laid and jointed on concrete bed complete including testing all as specified. |
| 81 | M&L for cutting into existing manholes for connecting new drains of Internal dia of pipe in 150 mm , making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required |
| 82 | Material and labour for Point wiring with 1.5 Sqmm FR PVC insulated and sheathed multi stranded (FRLSH) copper conductor cable in and incl rigid PVC conduit concealed /PVC surface conduit with sunk cast iron/pressed steel terminal boxes of adequate size with suitable thickness hylum laminated sheet , cover of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm (FRLSH) PVC insulated and unsheathed multi stranded copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed by Engr-in-charge. Note: (a) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc(b) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan etc with proper fixing clips all as directed |
| 83 | All as per serial item No 82.00 here in before but for one 3 pin 5 Amp socket outlet on independent board. |
| 84 | Material and labour for Point wiring with 4.0 sqmm FR PVC insulated and sheathed multi stranded (FRLSH) copper conductor cable drawn in and including rigid PVC concealed conduit medium grade of suitable size with sunk cast iron/pressed steel terminal boxes of adequate size with suitable thickness plastic laminated sheet, cover for one 6 pin socket outlet 15 Amp on independent board including continuous 4.0 sqmm copper conductor cable (FRLSH) (multistranded) PVC insulated and unsheathed Cable as earth wire to common earth dolly, complete all as specified and directed by Engr-in-charge |
| 85 | Material and labour for ceiling rose surface bakelite two to three terminal isolated body fixed on PVC round block, 6A, Pilot 2 Plate, complete all as specified and directed by Engr-in-charge |
| 86 | Supply and fixing of LED fitting 1x18 watts including Tube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and including provision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23x0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed. |
| 87 | M&L for LED Bulk head light of capacity 10W Pressure die cast AL housing IP 65 protected. Complete all as directedMake: Crompton of cat pt no. LBHE-10-CDL, Havell's Cat part No- HEXAFT10WLED857SSYMBOPC of crompton or euivalent model of HPL/ Philips/ Bajaj. |
| 88 | Supply and fix of DB 8 way MCB SPN double door, glazed type, IP 43 protection,Glazed door, isolated neutral bar,insulated bus bar assembly,mechanical strength of IK09, complete all as specified and directed. |
| 89 | Supply & fix of MCBs single pole (SPN) 6 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed. |
| 90 | Supply & fix of MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed. |
| 91 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust , common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thick RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including testing on completion. Note: The rate quoted shall be inclusive of GI wire 4 mm dia with GI pipe protection 15 mm, light grade up to 7.5 m) |
| 92 | S&F Metal flush Box 3 Module, complete all as specified and directed by Engr-in-charge |
| 93 | S&F Metal flush Box 8 Module, complete all as specified and directed by Engr-in-charge |
| 94 | S&F Modular Plate 3 module White cover plate with frame, complete all as specified and directed by Engr-in-charge |
| 95 | S&F Modular Plate 8 module White cover plate with frame, complete all as specified and directed by Engr-in-charge |
| 96 | M&L for Modular type 5 step Fan Regulator - 2 M oro white, complete all as specified and directed by Engr-in-charge |
| 97 | M&L for Modular switch 6 A One way switch white, complete all as specified and directed by Engr-in-charge |
| 98 | M&L for Modular 6 A, 5 pin socket, complete all as specified and directed by Engr-in-charge |
| 99 | M&L for Modular 6 A/16 A socket, complete all as specified and directed by Engr-in-charge |
| 100 | M&L for Modular 16 Amp One way switch white, complete all as specified and directed by Engr-in-charge |
| 101 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm all as specified and directed. |
| 102 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC). |
| 103 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as directed. |
| 104 | M&L for cutting of circular hole at any type of wall suitable size for fixing of exhaust fan of size 250mm sweep, grouting 04 Nos 100mm long 12mm dia stud bolt including, making good to disturbed surfaces of wall to match as per the existing colour complete as directed and specified by Engineer-in-charge. |
| 105 | Supply and fixing electric water heater (Geyser) storage type 25 Ltr capacity, BEE 5 star rated, vertical type, with fastner including provision and connecting up SS braided pipe with adapter for inlet and outlet water connection, copper element corrosion resistantance anti scaling magnesium anode, having adjustable knob for temperature control and inner tank material of superior glass line coating, metal body with high pressure material with standing capacity upto 8 bar pressure, multiple safety system for protection against dry heating, over heating and over pressure, waterproof technology for longer product life having heating element 2 KW including all accessories such as safety valve, thermostat, NRV and minimum 2 year warrenty on product, 3 years on Heating Element and 7 years on Tank complete all as specified and directed complete all as specified and directed. |
| 106 | S&F Sheet metal enclosure having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp. |
| 107 | M&L for Dummy Plate - 1 Module Oro (White), complete all as specified and directed by Engr-in-charge |
| 108 | Excavating in trenches not exc 1.5m wide and not exc 1.5m deep and getting out in soft / loose soil complete all as specified and directed |
| 109 | Removing excavated materials (soils) to a distance not exc 50.00 mtr and depositing where directed at a level not exc 1.50 mtr above the starting point, complete all as specified and as directed. |
| 110 | M&L for HDPE Double wall corrugated pipe of size 63/50 mm as per IS: 16098 Part-II-2013 and ISO 21138 & BSEN 13476-1TO 3 laid in trenches/wall for protection cables complete all as specified and directed. |
| 111 | S&F Double wall corrugated pipe coupler for pipe size 63/50 mm all as directed by Engr-in-Charge. |
| 112 | M&L for tubes 50 mm bore light grade galvanized iron with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ where ever reqd ] of proper sizes for protection cables complete all as specified and directed. |
| 113 | All as per above item no.112.00 here in above but bore size 40 mm complete all as directed. |
| 114 | Supply, laying, connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable of size 16 sqmm 4 core (heavy duty), aluminium stranded conductor 1100 volts grade, laid through duct/ pipe / in trench etc. including cable glands & lugs complete all as specified and directed. |
| 115 | Supply, install, testing and commissioning outdoor type LT feeder panel of suitable size , CPRI approved factory made totally enclosed dust and vermin proof , double steel shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both ront and rear door painted with powder coated paint and aluminium bus bar 400 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board complete with the following items:- (Distribution Panel). |
| 116 | Incoming :-(a) MCCB, 4 Pole,100-125 A, 415 V 36 kA (I/C). (b) CT 320/5 A, VA 12(c) Phase indicator lamps (RYB) -set of 3(d) Aluminium bus bar 4 strip(e) Internal wiring for panel incl insulators, sleeves etcOutgoing :-(a) MCCB, 4 Pole, 50-63A, 415 V 36 kA (O/G-02). |
| 117 | M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead strip 32 X 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel covered with 40mm GI light grade pipe all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.Note: (i) Item of earthing includes cost of 40mm bore medium grade GI protection Pipe (7.5 Meters long) for earth lead including test point complete. (ii) On testing after completion of earthing if the desired earth resistance of 5 ohm is not obtated earthning will be re-done by the contractor at his own risk and cost to the entire satisfaction of Engr-in Charge. |
| 118 | Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for foundation of pole and laying of CI/GI/DI/PPR pipe and getting out in Hard/dense of soil, complete all as specified and directed by Engr-in-charge. |
| 119 | Supply and fix of 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings with proper clamping system outer diameter of pipe 40mm, complete all as specified and directed by Engr-in-charge. |
| 120 | Supply and fix in replacement of PP-R Gate valves (brass insert) as per requirement of the site of size 40 mm bore, complete all as specified and directed by Engr-in-charge. |
| 121 | Material and labour for construction of brick masonry valve chamber of size 600mm x 600mm x 750mm (Internal dimension) with PCC 1:3:6 foundation 150mm thick, brick work 23cm thick built in CM 1:6, PCC 1:3:6 coping 50 mm thick, plastering 15mm thick in CM 1:4 to all internal and exposed surfaces including excavation earth work in any type of soil, MS sheet cover 3mm thick fixed with angel iron frame 30x30x4 mm including hinges of size 125mm with locking arrangement embedded in PCC and painting ot MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc, complete all as specified and directed by Engr-in-charge. |
| 122 | Material and labour for Drilling and tapping DI/cast iron water mains (in position) for branch connections of the internal dia 20 mm bore complete all as directed. Please Enable Macros to View BoQ information |