|
| 1 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc.15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | Dismantling of stone slab and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar including removing the dismantled material complete all as specified and as directed. |
| 3 | Demolition of cement concrete (unreinforced) in kerb stone & the like of any description of and in any position not otherwise specifically provided for complete all as specified and directed |
| 4 | M&L cement concrete 75mm thick 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified & directed. |
| 5 | M&L cement concrete 75mm thick 1:2:4 type B-2 using 40mm graded stone aggregate as in pathways/hardstanding laid in alternate ways, each panel not exceeding 3.00 Sqm finished the surface even and fair without using extra cement and joint to be filled with Bituminous mastic filling including necessary form work complete all as specified & directed. |
| 6 | M&L for rubber moulded concrete coloured tiles with grey cement and pigment of size 300mmx300mmx22-25 mm thick laid over and including 20 mm thick cement mortar screed bed in CM 1:6 as in floors complete all as specified & directed. |
| 7 | M&L for heavy duty coloured exterior grade tile of size 300mmx300mmx10mm thick as in floors set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match the shade of tiles over and including bedding layer of 15 mm thick screed bed 1:6 complete all as specified & directed. |
| 8 | M & L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade laid over sand cushioning complete all specified and directed.Note :- Sand cushioning will measured and paid seperately. |
| 9 | S&F for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and no pigment laid over sand cushing complete all as specified & directed.Note :- Sand cushioning will measured and paid seperately. |
| 10 | S&F for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade with grey cement and no pigment laid over sand cushing complete all as specified & directed.Note :- Sand cushioning will measured and paid seperately. |
| 11 | All as per item No 08 herein before but except tiles (old tiles to be re-used). |
| 12 | All as per item No 09 herein before but except tiles (old tiles to be re-used). |
| 13 | Supply and laying of sand including spreading, levelling and ramming in layers n.exc. 25 cm thick in each layer complete all as directed |
| 14 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required etc complete all as specified and directed. |
| 15 | All as per item No 14 herein before but except cement concrete Kerb stone (old kerb stone to be re-used). |
| 16 | M & L for preparation of kerb stone new un-treated concrete or plastered surfaces of any description over 10cm girth or width, not otherwise described and applying two coats of synthetic enamel paint in black and white colour over a coat of primer complete all as specified and directed. |
| 17 | M & L for preparation of kerb stone old painted concrete surfaces or plastered surfaces of any description over 10cm girth or width, not otherwise described and applying two coat of synthetic enamel paint in black and white colour complete all as specified and directed. |
| 18 | M&L cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channel, gap between road & road side kerb stone and the like including finishing the top of benching even and smooth using extra cement complete all as specified & directed. |
| 19 | M & L for cleaning and preparing the road surface and marking with reflective thermoplastic white/yellow road marking paint conforming to BIS-3262-1989, laid through road marking machine in 2.5 mm thick layer of CRYSTALEX using 5 Kg material per square meter by incorporating the white glass beads @ 250 gms/Sqm for reflectivity for lines, dashes, arrows, zebra marking etc all as specified and as directed. |
| 20 | S & F in repairs solar cat eyes (solar studs) made of aluminium dicasted body, 100% waterproof, both side reflectors, designed according to IP 65 of size 125mm x 125mm x 25mm with shank not less than 60mm length, high efficiency mono crystaline solar panel (2.5 V/0.3 watt), one Ni-Mh or Ni-cd rechargable battery (1.2 V/1600 MA) having six super bright LEDs with 10000 to 18000 mcd (millicandela), view distance upto 1000 metre and flush road bearing capacity 10 MT, fixing in road by drilling a hole and with epoxy hardner etc as per manufacturer's instructions at the location complete all as directed. |
| 21 | S&F in repairs ABS body Twin moulded shank cat eye of size 100 x110 x20 mm with both side red/yellow colour reflector, fixed with epoxy on road surface complete all as specified and as directed. Make: DA-52 of Dark eye or equivalent make in list of makes. |
| 22 | S&F in repairs Solar delinator 1200mm long flashing rate 30 times per minute Electronically operated with Solar cell, Battery NI-CD 1.2 V bottom frame aluminum, reflective frame Polycarbonate. Grouted in PCC Block of 30cmx30cmx30cm of PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) and including necessary excavation, earth work and removal of soil, complete as per manufacturers instructions & as directed.Make : CAT Part No DA-112 (Solar Delineator) of Dark Eye or equivalent in list of makes |
| 23 | Supply and fixing metal tubular dealineator made out of ABS round body fitted with 2 Nos 65 mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 (150x150x300mm) type B1 complete all as specified and directed. Make : Cat Part No DA-952-GP of Dark Eye or equivalent equivalent in list of makes. |
| 24 | Dismantling of Sign/information board of any description, shape & size including post and frame all as specified and directed. |
| 25 | Excavating in post holes (or similar holes) each n exc 0.5 Cu.m, getting out in soft/loose soil and removing surplus soil to a distance n exc 50m complete all as specified and directed. |
| 26 | M & L for Cement Concrete type C 2 1:3:6 using 40 MM graded stone aggregate as in foundation filling and mass concrete in fixing of fencing post including necessary form work if required at site complete all as specified and directed. |
| 27 | M&L Stainless steel Square/Round pipe of SS 304 grade for frame work as in post & frame of sign boards with SS plate, nut, bolts etc including drilling/welding/reveting for fixing of ACP sheet complete all as specified and directed. |
| 28 | Supplying & fixing retro reflective sign board made of high intensity retro reflective sheeting pasted on both sides of 3mm thick ACP sheet with letters/graphics to be overlayed high intensity retro reflective sheeting as per I.R.C./MORTH duty plotted cut of approved colour fixed with SS frame work complete all as specified and directed by Engineer-in-Charge.Note : SS Frame work will be measured as paid seperately. |
| 29 | Supplying & fixing retro reflective sign board made of high intensity retro reflective sheeting pasted on one side of 3mm thick ACP sheet with letters/grphics to be overlayed high intensity retro reflective sheeting as per I.R.C./MORTH duty plotted cut of approved colour fixed with SS frame work complete all as specified and directed by Engineer-in-Charge.Note : SS Frame work will be measured as paid seperately. |
| 30 | S&F in repair Convex mirror 100cm of polycarbonate material on road junction and corners with adjustable brackets complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F in repair triangular cautionary / warning sign boards of size 60cm equilateral triangle made out of 2mm thick alco bond sheeting confirming to IS 736 provided with cautionary /warning sign/ littering etc. made out of high intensity retro reflective sheet pasted firmly without appearance /sign of bubbles over a base layer of retroreflective sheet hoisted on and including angle iron post 40mmx40mmx6mm ,3 meter long painted in black and white 20cm wide alternative strips with and including one definition plate of size 600mmx200mm duly pasted with matter and post embedded in PCC(1:2:4) block of size 30x30x50cm including necessary excavation and earth work complete all as specified and directed. |
| 32 | S&F stainless steel (Gde 304) letters made of hollow tubes, plates including welding, grinding, buffing polishing fitting as per size and design approved by GE with necessary frame work where required, made of mild steel hollow section of 25 mm Square pipe, necessary accessories required for fixing and in any position up to 10 mtr height and all steel surfaces will be painted one coat of primer and two coats of synthetic enamel paint for measurement purpose height of each word will be measured. |
| 33 | S&F in repair round mandatory sign boards of size 300 mm dia made out of 2mm thick bond sheeting as per IRC standard,round red colour intensity grade retro reflective sheet is fixed on the border 75 mm wide and white retro reflective sheeting fixed in the centre of the board .The logos are of black colour printed and fixed after etching treatment with suitable adhesive .Sign board shall be fixed on 45 cm equilateral triangle made out of angle iron of size 35mmx35mmx5mm fixed with nuts,bolts and rivets.Sign board shall be fixed on one vertical post of 50mmx50mm square pipe ,3m long painted in black and white alternative band 25 cm size.One definition plate of size 600mmx 200mm made of 3mm thick alco bond sheet high intensity grade retro reflective sheeting is fixed on the definition plate and matter as approved by Engineer -in-charge shall be fixed on board with suitable adhesive complete all as specified and directed. |
| 34 | Scarifying and picking up gravelled, Macadam or Bituminus macadam surface area exc 400 sqm and any thickness etc complete all as specified and directed. |
| 35 | Scarifying and picking up gravelled, Macadam or Bituminus macadam surface area n exc 400 sqm and any thickness etc complete all as specified and directed. |
| 36 | Repair to potholes any depth, not exceeding 1 sqm each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc., cutting around edges to at least 25 mm in depth, making good by filling in screened & graded road metal, watering and well ramming (including supply of road metal), rolled and compacted with power roller 8 to 10 tonnes to required gradient and camber complete all as specified and as directed. |
| 37 | M&L for 75mm thick (compacted thickness) WBM, with granite, trap or basalt coarse aggregates of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size), spread, rolled and consolidated to gradient and camber as required etc complete all as specified and directed. |
| 38 | M & L for preparing of WBM surface by brushing with the wire burushes for removing caked mud etc sweeping with brooms and finaly fanning the cleaned surface with gunny bags to remove loose dirt etc and applying evenly a priming /tack coat with cationic bitumen emulsion RS-1 grade at the rate of 10 kg per 10 sqm of surface complete all as specified and as directed. |
| 39 | M & L for dense bituminous macadam 50 mm to 75 mm (compacted thickness) using graded crushed stone aggregate premixed with binder (paving grade bitumen VG-30 grade) @ 4.0% by weight of total mix & hydraulic lime filler, rolled and compacted to required camber and gradient complete all as specified and as directed.Note :- (i) Dense Bituminous macadam shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper.(ii) The exact bitumen content required shall be determined following the Marshall Mix Design procedure contained in the Asphalt Institute Manual MS-2 (Sixth Edition) as referred in case 3.5.3 of IRC 111: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg. |
| 40 | M & L for preparing newly laid bitumen macadam black top surface by brushing with the wire burshes for removing caked mud etc sweeping with brooms and finaly fanning the cleaned surface with gunny nbags to remove loose dirt etc and applying evenly a priming /tack coat with cationic bitumen emulsion RS-1 grade at the rate of 3 kg per 10 sqm of surface complete all as specified and as directed. |
| 41 | M&L for preparing old black top/ Scarifying surface by brushing with the wire burushes for removing caked mud etc sweeping with brooms and finaly fanning the cleaned surface with gunny bags to remove loose dirt etc and applying evenly a priming /tack coat with cationic bitumen emulsion RS-1 grade at the rate of 5 kg per 10 sqm of surface complete all as specified and as directed. |
| 42 | M & L for semi dense bituminous concrete 30 mm (compacted thickness) using graded crushed stone aggregate premixed with binder (paving grade bitumen VG-30 grade) @ 5.5% by weight of total mix & hydraulic lime/ cement or any other approved filler, rolled and compacted to required camber and gradient complete all as specified and as directed.Note :- (i) Semi dense bituminous concrete shall be laid using self propelled hydrostatic paver finisher and preparation of mix shall be using hot mix plant and transporting the mix in tipper.(ii) The exact bitumen content required shall be determined following the Marshall Mix Design procedure contained in the Asphalt Institute Manual MS-2 (Sixth Edition) as referred in case 3.5.3 of IRC 111: 2009. The adjustment in rate due to variation in quantity of bitumen if any shall be priced at the rate of ₹44 per kg. |
| 43 | Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) & removal complete all rubbish materials upto 1.0 Km from site etc complete all as specified and directed. |
| 44 | Dismantling of Stone slabs and tiles incl bedding of any description or thickness in floors, aprons etc,laid dry or laid dry and pointed etccomplete all as specified & directed. |
| 45 | M&L for 75mm thick PCC (1:2:4) type B1, using 20 mm graded stone aggregate in floor, finishing the suface even and smooth with out using extra cement incl necessary form work and joint to be cut at 1.5mtr in length or as directed by Engr-in-charge on laid concrete etc complete all as specified and directed. |
| 46 | M&L 10mm thick cement plaster on external surface in CM 1:4 mixed with WPC @ 3% by weight of cement including finishing fair & smooth (Without using extra cement) after removing of loose surface of kerb stone etc complete all as specified and directed. |
| 47 | Supply only Integral water proofing compound in plaster complete all as specified and directed. |
| 48 | S&F in repair PVC (SWR) pipes of 110 mm nominal outside diameter (Type B with wall thickness 3.20 to 3.8 mm) single socketed in any length with rubber ring joints laid in trenches or in floors incl taking out old u/s PVC/CI pipe with fittings |
| 49 | Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T & P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete all as specified and as directed. |
| 50 | Supply and fixing in repairs cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions fixed with suitable nails or screws etc complete all as specified and directed. Please Enable Macros to View BoQ information |