| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth and getting out in soft/loose soil for laying of cable etc complete all as specified and directed by Engr in charge. |
| 2 | M&L for returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil all as specified and directed. |
| 3 | M&L for removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point all as directed. |
| 4 | Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified and directed. |
| 5 | Supply and laying in trenches dry well burnt locally available sub class “B” bricks over sand cushioning for protection of cable complete all as per specified and directed. |
| 6 | M&L for tubes 80 mm bore light grade galvnized with all fittings laid in trenches/wall/ pole through MS flat (25x3 mm) nut bolts & washers(where ever required) of proper sizes for protection cabls complete all as specified and directed by Engr-in-charge. |
| 7 | M&L for tubes 50 mm bore light grade galvnized with all fittings laid in trenches/wall/ pole through MS flat (25x3 mm) nut bolts & washers (where ever required) of proper sizes for protection cabls complete all as specified and directed by Engr-in-charge. |
| 8 | Supply and laying heavy duty armoured LT underground cable 1100 V grade XLPE insulated,PVC sheathed multi stranded aluminium conductor of sizes 35 Sqmm 3.5 core in pipe/trenches/cable duct/ fixed on wall by proper size of shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortor/painting to match the existing,connecting with all accessories lugs and glands as required all as specified and diected by Engr-in-charge. |
| 9 | All as per serial item No. 8.00 here in above but of size 50Sqmm 3.5 core |
| 10 | All as per serial item No. 8.00 here in above but of size 90Sqmm 3.5 core |
| 11 | All as per serial item No. 8.00 here in above but of size 150Sqmm 3.5 core |
| 12 | All as per serial item No. 8.00 here in above but of size 185Sqmm 3.5 core |
| 13 | All as per serial item No. 8.00 here in above but of size 10Sqmm 2 core |
| 14 | S&F cable End jointing kit for 1.1 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150Sqmm & 90Sqmm all as directed. |
| 15 | S&F cable jointing kit for 1.1 KV (Earthed) grade cable for straight through shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm all as directed. |
| 16 | Cable jointing kit for 1.1 KV (Earthed) grade cable for straight through shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size up to 70 sqmm all as specified and directed. |
| 17 | M & L for earthing complete with copper plate electrode 600x600x3.15 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to coopper strip 20x3mm by means of brass nut, bolts, check nut, bolt, washer & GI light grade protection pipe for earth wire from the earthing plate to the DB/main switch/panel, (40mm bore, light grade,) watering pipe from plate to earthing pit (20mm bore, medium grade) funnel wire mesh. The earthing pit made up of PCC 1:3:6 type CI and pit cover made up of 40 mm thik precast RCC 1:2:4 type BI reinforced with 6 mm dia TMT rod and suitable handle of 8 mm dia TMT rod incl all necessary earth work i.e. excavation, returning filling, removal of excess soil as shown in SSR Part-I plate no.5 as specified and directed. Please Enable Macros to View BoQ information |
| 18 | M & L for earthing complete with copper plate electrode 600x600x3.15 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to coopper strip 20x3mm by means of brass nut, bolts, check nut, bolt, washer & GI light grade protection pipe for earth wire from the earthing plate to the DB/main switch/panel, (40mm bore, light grade,) watering pipe from plate to earthing pit (20mm bore, medium grade) funnel wire mesh. The earthing pit made up of PCC 1:3:6 type CI and pit cover made up of 40 mm thik precast RCC 1:2:4 type BI reinforced with 6 mm dia TMT rod and suitable handle of 8 mm dia TMT rod incl all necessary earth work i.e. excavation, returning filling, removal of excess soil as shown in SSR Part-I plate no.5 as specified and directed. Please Enable Macros to View BoQ information |