| Sl. No. | Item Description |
| 1 | Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out soft/loose soil complete all as specified and directed. |
| 2 | M&L for excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed. |
| 3 | M&L for PCC 1:4:8, type D-2 (40mm graded agg) as in foundations,filling and mass concrete complete all as specified and as directed. |
| 4 | M&L for Pre-cast cement concrete block masonry with solid blocks 1:3:6, type C-1, exc 10cm in width and setting in mortar in CM 1:6 complete all as speified and directed. |
| 5 | M&L for 40mm thick DPC (Damp proof course) to horizontal or vertical surfaces in cement concrete 1:2:4 type B-0 (using 12.5mm graded agg) incl necessary form work over laying of polythene film 50 micron thick laid on a coat of bitumen primer @ 0.30 to 0.50kg/sqm complete all as specified and directed. |
| 6 | M&L for RCC (nominal mix) in type B1, 1:2:4 (using 20mm graded agg) as in Beams, cantilevers, bressummers,lintels over 1.5m span complete all as specified and as directed. |
| 7 | S&F for Mild steel TMT bars 6-8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed. |
| 8 | -Ditto- all as per item No 7 here in before but 6mm to 8mm bars for stirrups |
| 9 | Use & formwork to sides and soffits of floor or roof beams,columns, lintels, cantilevers, shelves and similar work etc complete all as specified and directed |
| 10 | M&L for 15mm thick cement plaster in CM 1:4 on bricks on concrete surfaces finishing the surfaces even and smooth without using extra cement with two coats of cement base paint on new surface all as specified. |
| 11 | M&L for 15mm thick cement plaster in CM 1:6 on bricks on concrete surfaces finishing the surfaces even and smooth without using extra cement with two coats of OBD over a coat of primer on new surface all as specified. |
| 12 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm of soft/loose soil complete all as specified and directed |
| 13 | Removing excavated material n.exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point of soil complete all as specified and directed. |
| 14 | S&F for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) incl distance pieces, cleats etc. conforming Fe 410-W(Gde-E-250) quality-B complete all as specified and as directed. |
| 15 | S&F for plates (plain or chequred) channels, square cut to notched(ordinery and counter sunk) forming holes, without any attachment Fe 410-W(Gde-E-250) quality-A complete all as specified and as directed. |
| 16 | S&F for 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws with two corrugation side lap complete all as specified and as directed. |
| 17 | -Ditto- all as per item No 16 here in before but 0.50mm thick plain sheets on ridges |
| 18 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified & as directed . |
| 19 | S&F 15mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls, floor, ceiling etc complete all as specified & as directed . |
| 20 | S&F 20 mm bore GI tubing 'medium grade' galvanised, with all fittings and fixed complete to walls and ceiling or laid in floors all as specified and as directed. |
| 21 | M&L for cutting chases, pinning in making good to faces where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting n.exc 10cm girth on brick wall complete all as directed. |
| 22 | S&F in vitreous China wash down water closet pan (pedestel pattern) ETWC white, including trap connection to drain (outgoing pipe) and to flushing pipe, antisyphonage pipe, PVC jet for Pedestal pattern pan including 450/600mm long PVC connection and plastic water closet seat of white in colour, back closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device etc complete all as specified. Make : Cera/Prayag/Johnson Pedder. |
| 23 | S&F in vitreous China squatting pan Orissa pattern size 580 x 440mm white with integral foot rest (excluding flushing cistern and flush pipe), including P-trap (PVC) 100 mm dia., connection to flushing pipe, anti-syphonage pipe complete incl making good to floor all as specified. |
| 24 | S&F in vitreous china wash hand basin white of bowl size 550 x 450mm incl waste coupling and PVC waste pipe, 32mm dia, pillar tap cast copper alloy with capstan heads chromium plated fancy 5mm bore to be fixed with and incl MS brackets complete all as specified. Make : Cera/Prayag/Johnson Pedder. |
| 25 | S&F in 10 ltr capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve float ovel handle including brackets and PVC flushing pipe of polyethylene of low or high density or PVC 32mm dia complete all as specified. Make : Cera/Prayag/Johnson Pedder. |
| 26 | S&F in repair vitreous china Urinal, Half stall type, white including waste pipe and CP brass spreader for fixing with 15 mm dia pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plug with and incl 60mm long brass screws, pointing around urinal back in cement; flush pipe, grating and union for discharge pipe complete all as specified. |
| 27 | S&F PVC (SWR) soil, waste and vent pipes, 110 mm dia, in any length , single socketed,jointed with rubber ring joints/adhesive, fixed to wall, with PVC clamps, ISI marked complete all as specified and directed |
| 28 | S&F PVC (SWR) soil, waste and vent pipes, 75 mm dia, in any length , single socketed,jointed with rubber ring joints/adhesive, laid in trenches or in floors, ISI marked complete all as specified and directed |
| 29 | S&F PVC (SWR) bends, 110mm bore, any radius complete all as specified and directed |
| 30 | S&F PVC (SWR) bends, 75 mm bore, any radius complete all as specified and directed |
| 31 | S&F PVC (SWR) junction single (Single T) equal or 110 mm bore complete all as specified & as directed . |
| 32 | S&F PVC (SWR) junction single (Single T) equal or 75 mm bore complete all as specified & as directed . |
| 33 | S&F PVC vent cowl of 75mm dia complete all as specified and directed |
| 34 | S&F PVC vent cowl of 110mm dia complete all as specified and directed |
| 35 | S&F 110mm bore PVC (SWR) 'P’ trap fixed on floor with necessary PCC complete all as directed |
| 36 | S&F 75mm bore PVC (SWR) floor trap, plainwith grating including jointing with solvent cement complete all as directed |
| 37 | S&F in two way bib taps with wall flange quarter turn suitable for 15mm bore pipe long body fancy type brass CP, screwed down screwed for iron pipe or brass ferrule complete all as specified. Make Johnson VIVA new series Cat part No: T4808C or of equivalent |
| 38 | M&L for 15 mm bore fancy type stop cock chromium plated cast copper alloy with wall flange complete all as specified and directed |
| 39 | S&F in hand shower (health faucet) of ABS body with 1.0m long easy flexible tube in chrome finish and wall hook complete all as specified and directed by Engr-in-charge. Make : Jaquar Cat No ALE-ESS-585 or of equivalent |
| 40 | M&L PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified & as directed . |
| 41 | S&F in 600x450mm bevelled edge mirror of selected quality glass moulded on 6mm thick AC board or commercial plywood & fixed to wooden plugs with chromium plated brass screw. |
| 42 | M&L for broken stone hard core of gauge n.exc 63mm deposited, spread and leveled in layers not exc 15cm thick, watered and rolled, rammed to a true surface all as directed. |
| 43 | M&L for 75mm thick PCC type B- 2, 1:2:4 (40mm graded aggregate) as in sub base complete all as specified and directed |
| 44 | M&L for Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed bed or bedding of layer in CM 1:6 complete all as specified an directed |
| 45 | M&L glazed ceramic coloured tiles of size 450 x 300 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4 complete, all as specified. |
| 46 | M&L for machine cut 18-20mm granite (of any type) tiles machine cut, in skirting/dado laid over as as in shelves, partitions, cooking platform below granite stone and like incl necessary (of any type) 18-20mm (table top rubbed and polished) in steps, jambs, pillars, window cills, cooking platform, WHB platform and marble dust with admixture of pigment to match with marble shade incl 15mm thick screed bed and bedding of layer in CM 1:4 and making full curving the edges complete all as specified. |
| 47 | M&L for textured heavy duty exterior tiles of size 300x300x10mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with existing floor and including 20mm thick screed bed and bedding of layers in CM 1:6 including demolition of existing tiles complete all as directed. Make;Jhonson endura textured design or equivalent of Kajaria/Somany. |
| 48 | S&F in repair aluminium anodised powder coated ventilator using rectangular tube of size 63.50 x 25 x 1.50 mm including 3.50 mm thick designer glass louvers and stainless steel wire mesh 0.36 mm nominal dia of wire, average width of aperture 1.40 mm using ‘Jindal” aluminium section complete all as specified and directed by Engineer-in-Charge. |
| 49 | M&L for factory made 100% solid wood plastic composite (WPC) door frame single rebated 90mm x 45mm made from wood plastic composite (Single extruded process) material with density 780kg/ cum all as directed. Note:-During fixing of chowkat, surface shall be make good in plumb with existing finishes like cement plaster wall tiles, floor tiles etc and as per ans site requirement fixed with screws not less than 50mm on existing chowkats or timber framed work complete all as specified and directed |
| 50 | S&F for factory made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed |
| 51 | S&F for 125mm long aluminium anodised, barrel tower bolts of extruded section and fixed on door complete all as specified and directed |
| 52 | S&F for 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed on door complete all as specified and directed |
| 53 | S&F for 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed on door complete all as directed |
| 54 | S&F for 100mm size butt hinges, cast brass,with mild steel hinge pin, bright polished and fixed, type B-11 fixed on chowkat with brass/stainless steel screws complete all as directed |
| 55 | S&F for 125mm size extruded aluminium alloy handles, fabricated type,anodised fixed with screws on doors complete all as directed |
| 56 | S&F in 15mm dia Bib taps chromium plated with flange screwed for pipe and fixed on iron pipe complete all as directed Make: Essco or equvalent |
| 57 | S&F in 15mm dia angle cock chromium plated with flange screwed for pipe and fixed on iron pipe complete all as directed Make: Essco or equvalent |
| 58 | S&F in 15mm dia chromium plated fancy type pillar tap with extension body with fly nuts capstan head screwed down high pressure with or without lettered Hot or Cold with long screwed shank fixed with wall flange and fixed on iron pipe complete all as directed Make: Essco or equvalent |
| 59 | S&F in CP Soap Dish fixed with screws on walls complete all as specified and as directed. Make:Essco or equivalent |
| 60 | S&F in Tubular towel rail, 20mm dia, D type, 60cm long between flanges stainles steel fixed on walls complete all as specified and as directed. complete all as directed |
| 61 | S&F in chromium plated gratings 100mm dia with drain hole complete all as specified and as directed. Make: ISI Marked or of equivalent make as per Appx'A' as approved by GE |
| 62 | S&F rotational moulded polyethene water storage tank 3 layer white colour water tank non toxic effect, algea formation protection (made from virgin grade of polythethylene material which is duly stablized with anti-oxidant plastic) of capacity 1000 Litres (cylinderical verticle one piece moulded with closed top) the internal and external surfaces of tank are smooth, clean and free from any hidden internal defects, hoisted and fixed in position including S&F necessary GI fittings, inlet/ outlet washout, overflow pieces long nipples, checknuts, washers & 20mm dia PTMT valves high pressure of PTMT epoxy coated aluminum rod&high density plastic ball and 20mm brass stop cock etc complete including dismantling of existing water tank all as specified and directed. Make:Sintex, Polycon, Rotex |
| 63 | M&L for machine cut kota stone 20-25 mm thick slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbibg and polishing complete over 20mm thick screed bed or bedding the layer in CM 1:6 complete all as specified and directed |
| 64 | M&L 75mm thick PCC type C-2, 1:3:6 (20mm graded aggregate) as in plinth protection alid in alternate bays n.exc 3.0m length,finished surfaces even and smooth without using extra cement complete all as directed |
| 65 | S&F for glass dividing strips 3mm thick and 38mm width, inserted in position cofirm to design complete all as directed |
| 66 | M&L for 20mm thick plastering in two layers of CM 1:6 on brick or concrete wall surfaces etc with 2% of WPC on cement complete all as specified and as directed.(Note:WPC shall be measurned and paid in separatetly) |
| 67 | Supply only integral water proofing compound complete all as specified and as directed. |
| 68 | M&L for PCC (1:3:6) type C2 ( using 40mm graded broken stone aggregates) as in bed to drain pipes incl packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore of pipe complete all as specified and as directed. |
| 69 | M&L in 150mm bore RCC pipes, class NP2 laid and jointed with collars and tested drain pipes (salt glazed earthern ware, AC or reinforced concrete), set in cement mortar complete all as specified and as directed. |
| 70 | M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for 150 mm internal dia of pipe complete all as specified and as directed. |
| 71 | S&F in repair for factory made 50 mm thick, 900 mm x 650 mm manhole cover with additional frame for fixing, of precast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) finished the surface even and fare incl reinforcement MS TMT bars 6mm dia @ 150mm centre to centre both ways and set in CM 1:4 and handles including demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position complete all as specified and as directed. |
| 72 | M&L for point wiring with two runs of single core FRLS 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable confirming to IS drawn through and including PVC casing capping suitable width complete with all accessories including Modular PVC Flush Box for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm. copper conductor as earth wire connected to common earth dolly and earth in distribution board Complete all as directed all as specified (a) one light/exhaust fan/fan point controlled by one switch.Note: Modular Cover plates will be measured and paid seperately under relavent item. |
| 73 | One light point controlled by one switch Complete. |
| 74 | One 3 pin switch socket outlet, 5 Amps, independent Complete. |
| 75 | One fan & exhaust fan point controlled by one switch. |
| 76 | All as per item no 72 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm Complete. |
| 77 | S & F Modular switch one way 6 amp, 01 Module complete all as specified & as directed . |
| 78 | S & F Modular switch one way 16 amp, 01 Module complete all as specified & as directed . |
| 79 | S&F Modular socket 6A -2/3 pin combined 02 module complete all as specified & as directed . |
| 80 | S&F Modular socket 6A/16A -2/3 pin combined 02 module complete all as specified & as directed . |
| 81 | S& F modular white cover plate with frame 3 module complete all as specified & as directed . |
| 82 | S& F modular white cover plate with frame 6 module complete all as specified & as directed . |
| 83 | M&L complete for ceiling rose surface backelite three terminal 240 volts complete all as specified & as directed . |
| 84 | Supply and fix Extruded aluminium LED batten suitable for indoor application 20 watt , 4 feet complete including fixing arrangement to fix on Surface , Wall or steel truss mounted complete all as specified & as directed . |
| 85 | Supply and fix Extruded aluminium LED batten suitable for indoor application 10 watt , 2 feet complete including fixing arrangement to fix on Surface , Wall or steel truss mounted complete all as specified & as directed . |
| 86 | Supply and Fixing 35W High efficient LED Building Security light fitting around the building, Aluminium pressure Die cast housing with pure polyester powder coated for long life, High purity lenses for superior performance, IP66 protection, Suitable for external pipe dia Up to 54 mm, with Luminiare efficacy >95 lm/W, driver Voltage range 150-270V AC, temperature range- 0 to 50DegC, Driver efficiency > 85%, Power factor > 0.95, THD<10%, CRI >70, Colour Temperature- 5700K, ,Surge protection from overvoltage- 3.5KV in CM, Safety Extra Low Voltage Safe level<60V DC as per IEC standard, 50000 burning hours as per L70 Criteria, including provision of 40mm dia GI light grade pipe1.2 mtr length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete all as directed. Make: Havells Cat No. ENDURASUNDOWNSL35WLED765PASYBOPC or its equivalent make |
| 87 | Supply and fix and connecting up Heavy duty Exhaust fan of size 300mm sweep including loures, Minimum air delivery 1275 CMH, max power consumption 55W including louvers complete,with cable 3 core of size 1.5 sqmm from ceiling rose to fan, including writing MES No 2 cm height with synthetic enamel black paint all as complete in all respects all as specified and as directed Engineer in charge. |
| 88 | Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with integrated door earhting system, with tinned copper bus bar ,neutral link earth link complete all as directed. Make: Legrand cat No 507611 or its equivalent make |
| 89 | Supply and fix MCB DB SPN 4 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with integrated door earhting system, with tinned copper bus bar ,neutral link earth link complete all as directed. Make: Legrand cat No 507611 or its equivalent make |
| 90 | Supply and fix MCB SPN 32 Amps 240 volts 10 KA 50 HZ, C curve,Integrated level holder,colour coded on/off indication complete all as directed. Make- Legrand cat No 408617 or its equivalent make. |
| 91 | Supply and fix MCB SP 6 to 32 Amps 240 volts 10 KA 50 HZ, C curve,Integrated level holder,colour coded on/off indication complete all as directed. Make- Legrand cat No 408587 to 408595 or its equivalent make. |
| 92 | S&F sub main wiring drawing through PVC conduit with two single core 2.5 sq mm and one run of 2.5 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade Complete. |
| 93 | S & F submain wiring with 2 single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 4.0 Sqmm and one single core 4.0 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694/1990 drawn through including concealed in PVC conduit and conduit accessories heavy duty ISI marked, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed all as specified a Note :- ( Two runs of main copper wire, one run of earth wire cable & PVC conduit shall be measured together as one length). |
| 94 | M&L for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level, connected to galvanised iron or earth lead wire 4.0 mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion. |
| 95 | Supply and fix electric water heater, storage type Inner container material Steel with Glass and having 2 Nos Heating element type of Incoloy with Glass coated heating element upto 2 KW capacity 25 litre, 230 Volts 50 Hz , temp range 35 to 75 C, with 7 Years on Tank,4 Years on Heating Element and 2 Years on Other Parts, with Outer body material of ABS, PUF insulation, lined BEE 5 Star, with product dimension of 470x470x371mm rated vertical type complete with all accessories such as safety valve, thermostate, NRV, connection piece etc all as specified and directed by Engr-in-Charge. |
| 96 | Supply and fixing of geyser Bolt 120mm Long with nut & washers, complete all as specified and directed |
| 97 | Supply and installation of high-quality, durable material suitable for hot water applications 3 feet PVC connection for geyser, including all necessary fittings such as appropriate joints, couplings, or elbows as required for the installation, connections, and accessories including complete installation, testing, and making good of the site directed by Engineer-in- Charge complete all as specified and as directed |
| 98 | Supply and fix Sheet metal Enclosure with socket plug top and MCBs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps, 240 Volts 50 Hz all as specified Engineer-in- Charge complete all as specified and as directed |
| 99 | S & F in repair Galvanised Iron tubing, medium grade of dia 15 mm (1/2”) with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc for following size of pipes complete all as specified and as directed |
| 100 | S & F in repair Galvanised Iron tubing, medium grade of dia 20 mm (3/4”) with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc for following size of pipes complete all as specified and as directed |
| 101 | S & F in repair Galvanised Iron tubing, medium grade of dia 25 mm (1”) with all new connections and fittings such as tees, bends, elbows, short pieces, connector back nuts, diminishing pieces, caps, plugs unions etc for following size of pipes complete all as specified and as directed |
| 102 | Supply and fix Gate Valve, globe conforming to IS 9338,20mm dia pipe complete all as specified & as directed . |
| 103 | Supply and fix Gate Valve, globe conforming to IS 9338,25mm dia pipe complete all as specified & as directed . |
| 104 | Excavation in trenches not exceeding 1.5 metre wide and mot exceeding 1.5 metre in depth and getting out in Hard/dense soil including making the bottom of trenches levelled for proper laying of pipe line, foundation etc or for shafts, cesspits, manholes, pier hole etc not exceeding 10 sqm on plan and getting out in Hard/dense soil as as specified and as directed. |
| 105 | Cutting existing 40/50 mm steel tubing for alterations or additions (Each cut measured) complete all as specified & as directed . |
| 106 | Supply and lay 40 mm dia light grade galvanised Iron pipe with all fittings complete all as specified and directed |
| 107 | Cutting the existing bituminous road not less than 20 cm in depth for laying the GI pipe light grade and making good with PCC (1:3:6)type B1 using 20 mm stone aggregat up to the existing surface level and all as specified and directed . |
| 108 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core |
| 109 | S & F of DWC Pipe IS-16205, size inner dia 32 mm, outer dia 40 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed by Engr-in-Charge. |
| 110 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter in rough finished surfaces complete all as specified & as directed . |
| 111 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces CM 1:6 complete all as specified & as directed . |
| 112 | M&L for rendering 12mm thick on fair faces of brick work or concrete surfaces CM 1:4 complete all as specified & as directed . |
| 113 | M&L position suspended false ceiling system using T-grid suspended ceiling grid system. The size of grid shall be 600x600mm, with GI frame work main runner 38 x 24 x 3600mm, cross 'T' 25 x 24 x 60mm/25 x 24 x 1200mm and wall angle 24 x 24 x 2540mm (thickness of the material of 0.30mm ), using 9mm thick ceiling panel laminated with PVC film on front face and foil back available in due drop texture as per IS-2095, part-I-1996, fixed in the grid of T-grid suspended ceiling grid system duly suspended by 4mm dia GI bar hanger from the purlins of the roof with butterfly clips all as specifed and directed by Engineer- in -charge. Make:-Gyproc/Armstrong. |
| 114 | M&L for hardcore of gauge n exc 63mm, deposited, spread and levelled in layers n exc15cm thick, watered and rammed to a true surface |
| 115 | M&L for 75mm thick PCC type C-2,1:3:6 (20mm graded agg) as in sub base of floor complete all as specified and directed by Engr-in-Charge |
| 116 | M&L machine cut kota stone 20-25 mm thick over wall surfaces for skirting/ dado of the wall surfaces match with floor over 10mm thick cement plaster in CM 1:4 complete all as directed by Engr-in-Charge |
| 117 | S&F of 2nd class HW clean sawn timber framed and fixed in scantlings, to replace old and decayed timber of chowkhat or other works etc (including piecing,scarfing, etc of old and new timbers if required) and removing defective portions to store complete all as specified and directed |
| 118 | M&L for 35mm thick plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as speified and directed |
| 119 | M&L for glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Pt-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed |
| 120 | S&F in steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded with necessary holdfast incl PCC(1:2:4) and fixed to wall complete all as specified and directed |
| 121 | S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & as directed . |
| 122 | S&F mild steel med weigtht butt hinges medium weight 100mm all as specified and directed. NOTE :- All screws shall be self tapping chrome plated and length of screw not less 38 mm complete all as specified and directed. |
| 123 | S&F in 150 mm, helical door ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified. |
| 124 | S&F in 140 mm overall length of cover plate floor door stopper of aluminium alloy body and tongue, anodised,with hard drawn steel spring,fixed in floor complete all as specified and directed |
| 125 | M&L for preparation of new plastered surfaces of walls and applying two coats of OBD over a coat of primer complete all as specified and directed. |
| 126 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 127 | M&L for preparation of new surfaces of wood and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge. |
| 128 | M&L for treating the bottom and sides of excavation and under the plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as directed. |
| 129 | M&L for machine pressed precast cement concrete coloured interlocking paver blocks, glossy rubber moulded of triangular /Zigzag/ Haxagone/ any shape /design and size as approved, 60 mm thick, conforming to IS 15658-2006, M-35 with grey cement and pigments grade in floor/ paths/ pavement laid over and including 25 mm thick sand cushioning laid dry to the profile including filing the joints with sand, complete all as specified and as directed. Note: (i) Manufacturers test certificate shall be submitted alongwith sample. |
| 130 | M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH Cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH Cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed Socket outlet 05 Amp on same board. |
| 131 | Description all as per 1 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point,16 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed |
| 132 | S & F Modular Switch - 16 Amps, Single pole one way, one module complete all as specified & as directed . |
| 133 | S & F Modular Socket- 16 Amps, Single pole one way, one module complete all as specified & as directed . |
| 134 | S & F for wall mounted 20 watts indoor Inverter batten with opal diffuser, IP 20, with 3 to 4 hrs back up with out put of 2000 lumens , box type (decorative) light fitting, 230 volts with polycarbonate type body and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 20 watts complete all as specified and as directed. Make :- Halonix Cat part No.HLB-07-20-CW-INV ,Philips , Havells LHEXACP7FN1W020. |
| 135 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified & as directed . |
| 136 | Supply and fix exhaust fan, AC single Phase, working on input voltage 140-285 , of size 250 mm sweep, 1600 RPM, Power consumption16 W with BLDC Motor, blades, frame and louvers provision of 3 core 1.5 sq. mm copper conductor PVC insulated & PVC sheeted flexible wire from ceiling rose/connector to fan including making connections complete all as specified & as directed . Please Enable Macros to View BoQ information |
| 137 | Supply and fix exhaust fan, AC single Phase, working on input voltage 140-285 , of size 250 mm sweep, 1600 RPM, Power consumption16 W with BLDC Motor, blades, frame and louvers provision of 3 core 1.5 sq. mm copper conductor PVC insulated & PVC sheeted flexible wire from ceiling rose/connector to fan including making connections complete all as specified & as directed . Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail