| 1 | Excavation in trenches n. exc 1.5 m wide for foundations, laying cables / pipes etc. not exceeding 1.5 m deep and getting out in soft/ loose soil complete, all as specified |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified. |
| 3 | Removing excavated spoil to a distance exceeding 250m not exceeding 500 metre and depositing where directed complete, all as specified. |
| 4 | PCC type B-2 (1:2:4), using 40 mm graded stone aggregates as in foundation filling & mass concrete, complete all as specified. |
| 5 | PCC type C-1 (1:3:6), using 20 mm graded stone aggregates as in surface channel, drain etc, complete all as specified. |
| 6 | Precast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in manhole covers and the like duly placed on manholes with cement mortar (1:4) complete. |
| 7 | Supply only liquid water proofing compound ISI Marked. |
| 8 | Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified. |
| 9 | Brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:6), complete all as specified. |
| 10 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 11 | Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished fair & even without using extra cement on walls in cement mortar (1:4) using water proofing compound as per manufacturer recommended ratio,, complete all as specified. (WPC shall be measured and paid separetely.) |
| 12 | 110 mm bore uPVC pipes, type-B, ISI marked (IS:13592) double socketed in any length with or without rubber ring joints, fixed under floors / fixed to wall with MS clamp as SWR pipes, complete all as specified |
| 13 | 110 mm bore, uPVC/PVC bends any radius with acess door , complete all as specified. suitable for uPVC soil waste discharge pipes, IN REPAIRS, complete all as specified |
| 14 | 110 mm bore, uPVC/PVC junction single (Single T) equal or unequal with acess door jointed to pipe, IN REPLACEMENT, complete all as specified |
| 15 | 110 mm bore, uPVC/PVC vent cowl including jointed to waste pipe with cement solvent, IN REPLACEMENT, complete all as specified |
| 16 | Cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in bed to 110mm bore SWR pipes of any description including packing under and haunching against the sides of pipe complete all as specified |
| 17 | Removing / cleaning of blockage from traps of WC trap, bath rooms/ kitchen sink/ wash hand basin/ urinal point and gully traps of any description and in any position by removing sand/ sludge/ silt and other foreign material deposited in it (either manually or mechanically) upto first manhole and making the sewage system functional to the entire satisfaction of Engineer-in-Charge, complete. |
| 18 | Removing of blockage / cleaning of sewage lines 100mm / 150 mm bore laid at any depth (either manually or mechanically) by removing all type of sand/ sludge/ silt and any other foreign material deposited in it including manholes and removing the same outside MoD land in closed tanker & including sprinking of bleaching powder over their etc complete. |
| 19 | De-watering / liquid sludge of septic tanks and soakage wells with mechenically pumping set and draining including removing the same outside MoD land in closed tanker etc complete. |
| 20 | Taking out thick/solid sludge (sedimented sand sludge/grit ,ash rages , fibres and springe material etc) from septic tanks, soak well including inlet and outlet chambers and soakage well including removing the same outside MoD land in closed tanker etc complete. |
| 21 | Dewatering the over head water tank and then cleaning and removing all scales and dirt silt etc from water tank, removing lid and refixing the same in same position without disturbing pipe line system and float valve and making functional after cleaning and writing “cleaned on ..... .... (Date, month & year)“ format with white painting complete including removing of all previous writing all as specified of following capacity:- |
| 22 | Up to 500 Litre |
| 23 | Exc 500 but n exc 1000 Litre |
| 24 | Cleaning of static water tank by puming out all water with puming machine of capacity upto 50000 gallon and removal of all silt / rubbish,alkali, fungas small trees etc complete cleaning etc and after cleaning and writing “cleaned on ..... .... (Date, month & year)“ format with white painting complete including removing of all previous writing all as specified. |
| 25 | Demolition brickwork or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified. |
| 26 | Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) all as specified |
| 27 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided all as specified. |
| 28 | Demolition and breaking up 150mm bore drain pipes (salt glazed stoneware, AC or reinforced concrete) set in cement mortar all as specified |
| 29 | Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline. Please Enable Macros to View BoQ information |