| 1 | Taking down for servicing of split type AC 1.5/2.0TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner Or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections if required and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and as directed. |
| 2 | Taking down for servicing of Window type AC 1.5TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed. |
| 3 | Supply only Refrigerant gas R-22/R-32 in company sealed cylinder of capacity (Cylinders shall be return after use). complete all specified and as directed. |
| 4 | Supply only Refrigerant gas R-134/R-290 in company sealed cylinder of capacity (Cylinders shall be return after use). complete all specified and as directed. |
| 5 | Supply only Box type relay suitable for Window type AC 1.5/2.0 ton capacity complete all specified and as directed. |
| 6 | Supply only Thermostatic switch with knob suitable for window type AC 1.5/2.0 TR complete all specified and as directed. |
| 7 | Supply only contactor of capacity 30 Amp any type of AC 1.5/2.0 TR complete all specified and as directed. |
| 8 | Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5/2.0 TR Window type Air Conditioner complete all as specified and as directed. |
| 9 | Supply only Scroll complete with bush suitable for window/ split type AC complete all as specified and as directed. |
| 10 | Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5/2.0 TR Split type Air Conditioner complete all as specified and as directed. |
| 11 | Supply and fix in repairs starting relay for 1.5/2.0 TR compressor all as specified and directed. |
| 12 | Supply and fix in repairs over load protector for 1.5 TR compressor all as specified and directed. |
| 13 | Supply only Sensor Ac Volt (Temp Sensor) of any type and any size of AC |
| 14 | Dismantling of burnt swing motor of 1.5/2.0 TR split AC (indoor unit) and supply & fixing swing motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung as per sample complete all as specified and directed. |
| 15 | Supply only front front ventilation/suction window grill suitable for 1.5/2 ton window type AC complete all specified and as directed. |
| 16 | Supply and fix in replacement of Split AC Outdoor Unit (PVC/GI cover), AC Outdoor Grill Jali Round/square Shape (18 - 28 inch), Complete all as specified and directed |
| 17 | Supply only Dust Air filter for window type AC 1.5 / 2 ton capacity complete all specified and as directed. |
| 18 | Supply only Dust Air filter for Split type AC 1.5/2 Ton ton capacity complete all specified and as directed. |
| 19 | Supply only original remote of window/split type AC with battery of any type and any size of AC complete all specified and as directed. |
| 20 | S&F Compressor sealed unit of Window type Air Conditioner of capacity 1.5 TR reciprocating type by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes complete all specified and as directed. |
| 21 | S&F Compressor sealed unit for Split type Air Conditioner of capacity 1.5/2.0 ton reciprocating compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc. complete all specified and as directed. Note :- Charging of gas refrigerant will be paid and measured separately |
| 22 | Material and labour for replacement of copper tubing including cutting brazing, flaring and testing of size (1/2)\\"/(1/4)\\" x 22 SWG in required length including insulation of piping, complete all as specified and directed. |
| 23 | Material and labour for replacement of copper tubing including cutting brazing, flaring and testing of size (3/4)\\"/(3/8)\\" x 22 SWG in required length including insulation of piping, complete all as specified and directed. |
| 24 | Dismantling/taking down unsv window type air conditioner of any capacity and any type from any place/height and re-install the same at other location including testing, complete all as specified and directed. (Repair work and replacement of damaged parts shall be measured separately). |
| 25 | Taking out existing indoor unit of split type Air Conditioner including refrigerant lines and electrical connections of capacity 1.5 TR / 2.0 TR) and re-fixing at new location alongwith fixing arrangement with screwed on wooden gutka on wall surface and making good the disturbed surfaces complete all specified and as directed. (Note :- Excess requirement of refrigerant pipe line, electric connection cable ,drain pipe and topping up of refrigerant gas to be measured and paid separately under relevant item of this schedule) |
| 26 | M&L for leakage of copper pipe including gas kit and welding, soldering & insulation for leak arrest all as specified and as directed. |
| 27 | Dismantling of un-serviceable cooling coil unit any type any size of indoor unit of split type Air Conditioner of capacity 1.5 TR/2.0 by cutting the suction line and discharge line, and providing new cooling copper coil unit of indoor unit (of same capacity), including testing on completion complete all specified and as directed. |
| 28 | M&L for carrying out pressure leak test of split ACs 1.5 / 2.0 TR capacities by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all specified and as directed. Note : Cost of Nitrogen gas will be paid under respective schedule |
| 29 | Supply and fix in replacement of Foam type insulating flexible pipe & air tight outer tapping fitted on ACs of any capacity for suction / discharge copper tubes, complete all as specified and directed |
| 30 | S&F in repairs grass/wood wool cooling pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers including GI wiremesh and mesh size 100 x 100 mm complete all as directed . |
| 31 | Supply and fix in repairs of running capacitor 36-45 Mfd capacity in metal container pin type all as specified and directed. |
| 32 | Supply and fix in repairs of running capacitor 50±4 Mfd capacity in metal container pin type all as specified and directed. |
| 33 | Supply and fix in repairs of running capacitor 50±6 Mfd capacity in metal container pin type all as specified and directed. |
| 34 | M&L Cutting openings, through brick wall for fixing of window type Air Conditioner including necessary wooden frame work not less than 2\\" by 2\\" thick size as per AC model including fair finish of side walls in cement mortar (1:6) with three coats white wash, cleaning and stacking bricks removing surplus serviceable bricks, hard-core etc to store and rubbish not exc 50m complete all as specified and as directed. |
| 35 | S&F in relacement of cooling fan motor of window type AC of any capacity, Complete all as specified and directed |
| 36 | S&F in relacement of 1.5/2.0 TR, Split AC outdoor fan motor, single phase. 230V, 50Hz, 6P, 900 rpm, Thermally protected, Bolt thread 16mm from shaft end, shaft flat from the end of Bolt thread, Complete all as specified and directed |
| 37 | S&F in repairs, 2 Ton Tower AC outdoor unit fan motor, Rotation clockwise Thermally protected, complete all as specified and directed |
| 38 | Supply and fix in replacement of Heavy Duty AC stand, Rust Proof Iron for Air Conditioner Outdoor Unit with Mounting Bracket, Supports upto 150kg weight, complete all as specified and directed |
| 39 | S&F in repairs Condensor Coil (1.5/2.0 Ton) of split/window type AC, complete all as specified and directed |
| 40 | Supply and fix Indoor PCB (Printed Circuit Board) (Inverter/Non inverter) for split type AC of capacity 1.5/2 TR of any make complete all as specified and directed |
| 41 | Supply and fix PCB (Printed Circuit Board) for window type AC of capacity 1/1.5/2 TR of any make complete all as specified and directed |
| 42 | Dismantling of burnt blower motor of 1.5/2.0 TR split AC (indoor unit) and supply & fixing blower motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star as per sample complete all as specified and directed. |
| 43 | Material and labour for PVC Lead wire 2.50 sqmm stranded copper conductor 4 core (FRLSH) ISI Marked complete all as specified and as directed. |
| 44 | Material and labour for Fan vickret Blade of outdoor unit PVC/iron body with nut Bolt washer for split type AC of various makes complete all as specified and as directed. |
| 45 | Material and labour for replacement of PVC drain pipe (Flexible) ISI Marked including clip and all fixing arrangements complete all as specified and as directed. |
| 46 | Material and labour for replacement of Capilary tube (copper) of any type of AC and any sizecomplete all as specified and as directed. |
| 47 | Disconnecting of the unserviceable voltage stabilizers capacity upto 5 KVA from the site and removing to workshop for repair and re-fixing/testing/ commissioning at the original position after rewinding / replacement of parts/spares to the extent required /reassembling complete all as specified and directed. |
| 48 | Dismantling/taking down defective/unserviceable 5 KVA voltage stabilizer from the site and install with new 5 KVA voltage stabilizer from voltage 130v-280v complete with all connection and testing, complete all as specified and directed |
| 49 | Supply only main transformer with super enameled copper wire proper insulated upto 5 KVA capacity for volatage stabilizer complete as specified and directed. |
| 50 | S&F in replacement of auxiliary transformer for the 0.5 KVA to 5 KVA capacity stablizer of approved make complete all as specified and directed. |
| 51 | Supply only volt meter 0 to 300 volts complete all as specified and directed |
| 52 | S&F in replacement of main PCB for voltage stabilizer 0.5 KVA to 5.0 KVA of approved make complete all as specified and directed. |
| 53 | Supply and fixing in repair of compressor (sealed unit) with relay suitable for refrigerator of capacity 300 / 280 ltrs complete all as specified and as directed. |
| 54 | Supply and fixing in repair of compressor (sealed unit) with relay suitable for refrigerator of capacity of 165/175/195 Ltrs ltrs capacity complete all as specified and as directed. |
| 55 | S&F of hermetic sealed compressor suitable for deep freezer of capacity 200 ltrs to 320 ltrs including all necessary connection and gas charging complete all specified and as directed. |
| 56 | Supply and replacement of Thermostatic switch with knob suitable for Refrigerator complete all as specified and as directed. |
| 57 | Supply and replacement of over load protector relay suitable refrigerator any complete all as specified and as directed. |
| 58 | Supply and replacement of Box type relay suitable for refrigerator 165 to 310 ltr capacity complete all as specified and as directed. |
| 59 | Supply and replacement of Magnetic door gasket for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed. |
| 60 | Supply and replacement of freezer door for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed. |
| 61 | Supply and replacement of Vegetable tray for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed. |
| 62 | Supply only heavy duty stand for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed. |
| 63 | M & L for servicing of water coolers including cleaning of tank of any size and type complete all as specified and directed. |
| 64 | M & L for servicing of Deep freezer/refrigerator of any size and type complete all as specified and directed. |
| 65 | S&F bib taps with flange, cast copper alloy , fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed. |
| 66 | M&L for cutting/chases of wall for concealed of drain/copper pipe in the wall including plastering, painting and matching with existing surface, complete all as specified and directed. |
| 67 | M&L for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed in wall of the sizes 2x4 Sqmm with earth wire of 1x4 Sqmm including dismantling of old unsv submain wiring complete all as specified and directed. |
| 68 | Material and labour for Servicing of Desert cooler of any size, single phase 230 Volts of various makes after disconnecting incoming and outgoing electric/water connection drain out water and carry out minor repair work such as repairing of internal worn out wires, motor ,Pump, Fan vicket, Lead wire , switch regulator , and replacement of unserviceable parts including testing complete all as specified and as directed. (Note “ Spares required for eplacement shall be measured and paid separately as supply only in respective items) |
| 69 | Material and labour for Fan vickret Blade of PVC/iron body with nut Bolt washer for desert cooler of various makes complete all as specified and as directed. |
| 70 | S & F in repairs capacitor (ISI Marked) of capacity 4-6 Mfd suitable for Desert Cooler. Complete all as specified and directed. |
| 71 | Material and labour for wooden shelving pad for Desert cooler each set weighting not less than 500 grams all as directed of size 75 Cms x 60 Cms complete all as specified and as directed. |
| 72 | Material and labour for Front Grill Air Divertor of PVC with Selector Switch and 2 Nos. indicator for Desert Cooler 4000 / 6000 Cum/Hr complete all as specified and as directed. |
| 73 | Supply and fix in repair side/ back shutter fabric item made out of 1mm thick galvanised iron sheet of size suitable for desert cooler of air delivery capacity 4000/ 5000 Cum/hour in and including applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. |
| 74 | Material and labour for replacement of unsv Submerssible water circulation pump assembly with min head of 1.6 mtr, electic driven single phase, 230 volts, 18 watts for Desert coolers. complete all as specified and as directed. |
| 75 | Supply and fix in repair switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body all as specified and directed. |
| 76 | Supply and fixing in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp, complete all as specified and directed. |
| 77 | Supply and fix in repair stepped type electronic fan regulator,fives teps, for desert cooler complete all as specified and directed. |
| 78 | Supply and fix Plug top for desert cooler 3 pin 5 Amps, 230 Volt AC, ISI marked complete all as specified and as directed. |
| 79 | Supply and fix in repair Plug top 20 Amp ,3 pin, 240 Volt all as specified and directed. |
| 80 | Material and labour for PVC flexible pipe (from vertical pump to distributer and distributer to panele ) 15mm dia for Desert cooler including 3 way distributor junction tee set complete all as specified and as directed. |
| 81 | Material and labour for Flexible Core PVC insulated with stranded copper conductor 1.50 Sqmm 3 Core 600/1100 V ISI Marked complete all as specified and as directed. |
| 82 | Material and labour for PVC pipe connection, both end screwed 18” long 15mm dia with brass nuts and neoprene washers for water cooler/ desert coolers complete all as specified and as directed. |
| 83 | Material and labour for Painting of Desert cooler with two coats of enamel paint after surface preparation including paint, complete all as specified and as directed. |
| 84 | Material and labour for Repairs / Servicing of RO plant of any capacity including replacement of filters etc, PVC Pipe , and replacement of unserviceable filters etc including testing complete all as specified and as directed |
| 85 | Supply & fixing in repair Ball valves for pipe size 15/20mm high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed and fixed ISI Marked approved quality including taking down old unsv valves,complete all as specified and directed. |
| 86 | S & F in repairs desert cooler body of size 66x72x92 cm made out of 22 gauge GI sheet & water storage tank of including front grills & three side shutters duly fitted with wood pads & duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer (inside & outside) Complete all as specified and directed |
| 87 | S & F in repair desert cooler fan motor 3 speed, 1350/1400 RPM, 220V, 105W, Heavy Duty, copper winding ISI mark including suitable leg set of three including nut bolt washer all as directed. |
| 88 | Supply and replacement of wooden shelving pad for Air Ducting Cooler of size 6' x 6' x 6 feet with 4 Inch thick honeypad complete all as specified and directed. |
| 89 | Supply and installation in replacement of GI, Pre fabricated rectangular GI ducts of 20 SWG, Galvanised Iron Sheet thickness 0.70 mm complete with MS flanges and bracing (as specified), necessary supports using thread rods (as directed) and anchor bolts, supply air collars, vanes, splitters complete all as specified and directed. |
| 90 | Material and labour for making hole for AC pipe of size for 75/100 mm by core cutting only in wall/RCC, includingplastering, painting etc, to match with the existing surface complete all as specified and directed. |
| 91 | S&F in repairs selector switches three way 230 Volts single phase of standard quality fixed in desert coolers, complete all as specified and directed |
| 92 | Taking out & removing old existing plywood of any description and in any position and supplying and fixing new plywood 4mm thick, grade BWR, type BB, 3 ply, cut to size made to shape and fixed in position with nails as to make the window of desert cooler air tight complete all as specified and directed |
| 93 | Supply and fix in replacement Flame Retardant (FR) PVC casing caping of Size 40x40x3000 mm, Ivory/Grey/white Colour, for casing of AC copper pipe including fixing with screws, double lock, ISI Marked, Highly durability, complete all as specified and directed. |
| 94 | Supply & fixing in replacement of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on wall including necessary cutting, chasing and making good to match with existing surfaces, complete all as specified Please Enable Macros to View BoQ information |
| 95 | Supply & fixing in replacement of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on wall including necessary cutting, chasing and making good to match with existing surfaces, complete all as specified Please Enable Macros to View BoQ information |